Real-Time 3D Echocardiographic Quantification of Left Ventricular Volumes: Multicenter Study for Validation with Magnetic Resonance Imaging

被引:2
|
作者
Mor-Avi, V. [1 ]
Jenkins, C. [2 ]
Kuehl, H.
Nesser, H. J. [4 ]
Marwick, T. H. [2 ]
Franke, A. [3 ]
Ebner, C. [4 ]
Freed, B. H. [1 ]
Steringer-Mascherbauer, R. [4 ]
Pollard, H. [1 ]
Weinert, L. [1 ]
Niel, J. [4 ]
Sugeng, L. [1 ]
Lang, R. M. [1 ]
机构
[1] Univ Chicago, MC5084,5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Queensland, Princess Alexandra Hosp, Brisbane, Qld, Australia
[3] Univ Hosp, Aachen, Germany
[4] Publ Hosp Elisabethinen, Linz, Austria
关键词
D O I
10.1109/CIC.2008.4748968
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Left ventricular (LV) volumes obtained from RT3DE datasets are underestimated compared to cardiac magnetic resonance (CMR). We sought to study the accuracy and reproducibility of this technique in a multicenter setting, the inter-institutional differences in these variables in relationship with investigators' experience, and the potential sources of underestimation. 92 patients underwent CMR and RT3DE imaging at 4 different institutions. End-systolic and end-diastolic LV volumes correlated highly with CMR values (EDV: r=0.91; ESV: r=0.93), but were 29 and 26% lower. This finding was consistent across participating institutions, with the magnitude of bias being related to experience. Exclusion of trabeculae and mitral valve plane from the CMR reference essentially eliminated the inter-modality bias. In conclusion, LV volumes are underestimated in most patients because RT3DE imaging cannot differentiate between the myocardium and trabeculae.
引用
收藏
页码:25 / +
页数:2
相关论文
共 50 条
  • [21] FULLY AUTOMATED QUANTIFICATION OF LEFT VENTRICULAR AND LEFT ATRIAL VOLUMES FROM TRANSTHORACIC 3D ECHOCARDIOGRAPHY: A VALIDATION STUDY
    Tsang, Wendy
    Salgo, Ivan S.
    Zarochev, Lyubomir
    Settlemier, Scott
    Bhave, Nicole
    Weese, Juergen
    Waechter-Stehle, Irina
    Cardinale, Michael
    Prado, Aldo
    Weinert, Lynn
    Patel, Amit R.
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E904 - E904
  • [22] Assessment of right ventricular volumes and ejection fraction by real-time 3-dimensional echocardiography in children: A validation study compared with magnetic resonance imaging
    Lu, Xiuzhang
    Bu, Liping
    Nadvoretskiy, Vyacheslav
    Stolpen, Alan
    Ge, Shuping
    CIRCULATION, 2006, 114 (18) : 726 - 727
  • [23] Quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography: comparison with cardiovascular magnetic resonance
    Claver, E.
    Leta, R.
    Pujadas, S.
    Kociubinski, P. A.
    Costa, F. Carreras
    Pons-Llado, G.
    EUROPEAN HEART JOURNAL, 2005, 26 : 314 - 314
  • [24] Assessment of Right Ventricular Function by Real-Time 3D Echocardiography Closely Agrees With Magnetic Resonance Imaging
    Leibundgul, Gregor
    Kessel, Arnheid
    Bernheim, Alain
    Zellweger, Michael
    Buser, Peter
    Handke, Michael
    CIRCULATION, 2008, 118 (18) : S1001 - S1001
  • [25] Fusion of 3D echocardiographic and cardiac magnetic resonance volumes
    Kiss, Gabriel
    Thorstensen, Anders
    Amundsen, Brage
    Claus, Piet
    D'hooge, Jan
    Torp, Hans
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 126 - 129
  • [26] A New Image Processing (40 Auto LVQ) for 3D Echocardiographic Left Ventricular Volumes Quantification
    Macron, Laurent
    Bensaid, Alexandre
    Nahum, Julien
    Mitchell-Heggs, Laurens
    Deux, Jean-Francois
    Gueret, Pascal
    Lim, Pascal
    CIRCULATION, 2009, 120 (18) : S312 - S313
  • [27] Validation of real-time 3D echocardiography for precise calculation of left ventricle volumes and ejection fraction
    Chico, JLG
    Zamorano, JL
    Orejas, M
    Maluenda, LA
    de Isla, LP
    Aguilera, L
    Aznar, J
    Macaya, C
    EUROPEAN HEART JOURNAL, 2004, 25 : 260 - 260
  • [28] Accuracy of endocardial border tracking algorithms for real-time three-dimensional echocardiographic quantification of left ventricular volumes
    Soliman, O. I. I.
    Krenning, B. J.
    Geleijnse, M. L.
    Nemes, A.
    Anwar, A. M.
    Van Geuns, R. -J.
    Kirschbaum, S. W.
    Vletter, W. B.
    Galema, T. W.
    Ten Cate, F. J.
    EUROPEAN HEART JOURNAL, 2007, 28 : 488 - 488
  • [29] Real-Time 3D Magnetic Resonance Imaging of the Pharyngeal Airway in Sleep Apnea
    Kim, Yoon-Chul
    Lebel, R. Marc
    Wu, Ziyue
    Ward, Sally L. Davidson
    Khoo, Michael C. K.
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1501 - 1510
  • [30] Real time 3D echocardiographic study of left ventricular function after infarct exclusion surgery
    Qin, JX
    McCarthy, PM
    Shirota, T
    Firstenberg, MS
    Smedira, NG
    Hoercher, KJ
    Buda, T
    Tsuijino, H
    CIRCULATION, 1999, 100 (18) : 167 - 167