Real-Time 3D Echocardiographic Quantification of Left Ventricular Volumes: Multicenter Study for Validation with Magnetic Resonance Imaging

被引:2
|
作者
Mor-Avi, V. [1 ]
Jenkins, C. [2 ]
Kuehl, H.
Nesser, H. J. [4 ]
Marwick, T. H. [2 ]
Franke, A. [3 ]
Ebner, C. [4 ]
Freed, B. H. [1 ]
Steringer-Mascherbauer, R. [4 ]
Pollard, H. [1 ]
Weinert, L. [1 ]
Niel, J. [4 ]
Sugeng, L. [1 ]
Lang, R. M. [1 ]
机构
[1] Univ Chicago, MC5084,5841 S Maryland Ave, Chicago, IL 60637 USA
[2] Univ Queensland, Princess Alexandra Hosp, Brisbane, Qld, Australia
[3] Univ Hosp, Aachen, Germany
[4] Publ Hosp Elisabethinen, Linz, Austria
关键词
D O I
10.1109/CIC.2008.4748968
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Left ventricular (LV) volumes obtained from RT3DE datasets are underestimated compared to cardiac magnetic resonance (CMR). We sought to study the accuracy and reproducibility of this technique in a multicenter setting, the inter-institutional differences in these variables in relationship with investigators' experience, and the potential sources of underestimation. 92 patients underwent CMR and RT3DE imaging at 4 different institutions. End-systolic and end-diastolic LV volumes correlated highly with CMR values (EDV: r=0.91; ESV: r=0.93), but were 29 and 26% lower. This finding was consistent across participating institutions, with the magnitude of bias being related to experience. Exclusion of trabeculae and mitral valve plane from the CMR reference essentially eliminated the inter-modality bias. In conclusion, LV volumes are underestimated in most patients because RT3DE imaging cannot differentiate between the myocardium and trabeculae.
引用
收藏
页码:25 / +
页数:2
相关论文
共 50 条
  • [1] Real-Time 3D Echocardiographic Quantification of Left Atrial Volume: Multicenter Study for Validation with Magnetic Resonance Imaging
    Mor-Avi, Victor
    Yodwut, Chattanong
    Jenkins, Carly
    Kuhl, Harald
    Nesser, Hans-Joachim
    Marwick, Thomas H.
    Franke, Andreas
    Niel, Johannes
    Steringer-Mascherbauer, Regina
    Sugeng, Lissa
    Lang, Roberto M.
    CIRCULATION, 2011, 124 (21)
  • [2] Real-Time 3D Echocardiographic Quantification of Left Atrial Volume Multicenter Study for Validation With CMR
    Mor-Avi, Victor
    Yodwut, Chattanong
    Jenkins, Carly
    Kuehl, Harald
    Nesser, Hans-Joachim
    Marwick, Thomas H.
    Franke, Andreas
    Weinert, Lynn
    Niel, Johannes
    Steringer-Mascherbauer, Regina
    Freed, Benjamin H.
    Sugeng, Lissa
    Lang, Roberto M.
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (08) : 769 - 777
  • [3] Real-time three-dimensional echocardiographic quantification of regional left ventricular function: Validation by magnetic resonance imaging
    Corsi, C
    Sugeng, L
    Nasser, HJ
    Weinert, L
    Niel, J
    Ebner, C
    Steringer-Mascherbauer, R
    Schmidt, F
    Schummers, G
    Lang, RM
    Mor-Avi, V
    CIRCULATION, 2005, 112 (17) : U649 - U649
  • [4] Real-Time 3-Dimensional Echocardiographic Quantification of Left Ventricular Volumes
    Mor-Avi, Victor
    Jenkins, Carly
    Kuehl, Harald P.
    Nesser, Hans-Joachim
    Marwick, Thomas
    Franke, Andreas
    Ebner, Christian
    Freed, Benjamin H.
    Steringer-Mascherbauer, Regina
    Pollard, Heidi
    Weinert, Lynn
    Niel, Johannes
    Sugeng, Lissa
    Lang, Roberto M.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (04) : 413 - 423
  • [5] Real-time 3-dimensional echocardiographic evaluation of left ventricular volume: Correlation with magnetic resonance imaging - A validation study
    Lee, D
    Fuisz, AR
    Fan, PH
    Hsu, TL
    Liu, CP
    Chiang, HT
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2001, 14 (10) : 1001 - 1009
  • [6] Real-time three-dimensional echocardiographic quantification of left ventricular mass: Comparison with magnetic resonance imaging
    Mor-Avi, V
    Sugeng, L
    Caiani, EG
    Weinert, L
    MacEneaney, P
    Salgo, IS
    Lang, RM
    Computers in Cardiology 2004, Vol 31, 2004, 31 : 65 - 68
  • [7] Validation of real-time three-dimensional echocardiographic measurements of left ventricular ejection fraction with magnetic resonance imaging
    Sugeng, L
    MacEneaney, P
    Weinert, L
    Koch, R
    Mahia, P
    Bednarz, JE
    Furlong, KT
    Collins, KA
    Mor-Avi, V
    Lang, RM
    CIRCULATION, 2003, 108 (17) : 338 - 338
  • [8] Real-time 3-dimensional echocardiography for quantification of left ventricular volumes and ejection fraction: Comparison with magnetic resonance imaging and 2D echo
    Sun, JP
    White, RD
    Qin, JXX
    Shiota, T
    Agler, DA
    Stewart, WJ
    CIRCULATION, 1998, 98 (17) : 225 - 225
  • [9] Comparison of real-time imaging cardiac magnetic resonance for left ventricular volumes with conventional imaging in patients with atrial fibrillation: Is real-time required?
    Costa, SP
    Yeon, SB
    Kissinger, KV
    Chuang, MC
    Manning, WJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 436A - 437A
  • [10] Real-time 3D echocardiographic data analysis for left ventricular volume estimation
    Corsi, C
    Lamberti, C
    Sarti, A
    Travaglini, A
    Shiota, T
    Thomas, JD
    COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 107 - 110