Effects of Train-Induced Unsteady Airflow on Air Quality and Air Distribution in a Subway Station

被引:1
|
作者
Li, Hu [1 ]
Han, Hong [2 ]
Liu, Xinjin [3 ]
Chen, Shujing [3 ]
Wang, Jingqian [3 ]
Lei, Wenjun [4 ]
机构
[1] Jinan Rail Transit Grp Co Ltd, Jinan 250101, Peoples R China
[2] Shandong Jiaotong Univ, Sch Rail Transportat, Jinan 250357, Peoples R China
[3] Shandong Rail Transit Survey & Design Inst Co Ltd, Jinan 250101, Peoples R China
[4] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan 250101, Peoples R China
基金
中国国家自然科学基金;
关键词
PM2; 5; concentration; air velocity distribution; controllable vents; subway station; field test; numerical simulation; PARTICULATE MATTER; THERMAL ENVIRONMENT; VENTILATION SYSTEM; ENERGY PERFORMANCE; PISTON WIND; DOORS; VENTS;
D O I
10.3390/buildings12122114
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Using train-induced unsteady airflow in transitional seasons can greatly reduce the energy consumption of a subway station's mechanical ventilation. However, the unsteady airflow carries the particles from tunnels into subway platforms, and airflow distribution at controllable vents is uneven. To determine the variation in PM2.5 (particulate matter of 2.5 micrograms or less) concentration and the air velocity distribution at the vents, field tests were conducted. The results showed that the PM2.5 concentrations at the vents and platform were positively correlated with the air velocity. The average ratio of the PM2.5 concentration at the vents to that on the platform was 71.15%. The maximum PM2.5 concentration and average PM2.5 concentration on the platform were 0.067 mg/m(3) and 0.037 mg/m(3), respectively. The air velocity distribution along the length of the platform conformed to logistic regression. Adjustment of the opening height of the vents was proposed to improve the air velocity distribution. Through numerical simulation, the ratio of the minimum airflow rate to the maximum airflow rate was increased from 5.9% to 37.5% after adjustment. This method is helpful for the uniform distribution of the airflow rate. This study will provide references for the design and operation of the vents of subway stations.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Train-induced vibration on elevated railway station
    Na Yang
    Ting Guo
    Guo-zhong Sun
    Journal of Central South University, 2013, 20 : 3745 - 3753
  • [32] Numerical analysis on the condenser inlet air temperature of train-mounted air conditioner when a train stops in subway station tunnel
    Zhang, Yue
    Li, Xiaofeng
    SUSTAINABLE CITIES AND SOCIETY, 2021, 69
  • [33] Numerical Simulation on Ventilation Effect of Train-induced Wind in Subway
    Yang, Weichao
    Peng, Limin
    Shi, Chenghua
    Hu, Zilin
    ADVANCES IN COMPUTATIONAL MODELING AND SIMULATION, PTS 1 AND 2, 2014, 444-445 : 450 - +
  • [34] Prediction method for subway train-induced environmental vibration responses
    Liu, W., 1600, Chinese Academy of Railway Sciences (34):
  • [35] A STUDY ON THE INFLUENCE OF THE PISTON EFFECT ON THE AIR ENVIRONMENT QUALITY IN A SUBWAY STATION
    Zhang, L. L.
    Chen, C.
    Pan, S.
    Xu, L.
    Li, Z. Z.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1001 - 1006
  • [36] Effects of Indoor Air Quality in Subway Systems according to Changes in Outdoor Air Quality
    Son, Youn-Suk
    Yu, Seong-ji
    Seo, Seo Hee
    Choi, In-young
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2022, 38 (01) : 13 - 29
  • [37] TRAIN-INDUCED STRUCTURAL VIBRATIONS OF ELEVATED RAILWAY STATION
    Cheng, Q.
    Zhang, N.
    Xia, H.
    ENVIRONMENTAL VIBRATIONS: PREDICTION, MONITORING, MITIGATION AND EVALUATION, VOLS I AND II, 2009, : 178 - 183
  • [38] Modal based method to predict subway train-induced vibration in buildings
    Farahani, M. Vasheghani
    Sadeghi, J.
    Jahromi, S. Ghaffarpour
    Sahebi, M. Mahmoudi
    STRUCTURES, 2023, 47 : 557 - 572
  • [39] Air pressure and comfort study of the high-speed train passing through the subway station
    Li, Chanyuan
    Liu, Minzhang
    Chang, Ru
    Wang, Xiaoqiang
    Liu, Weiyue
    Zhang, Huan
    SUSTAINABLE CITIES AND SOCIETY, 2022, 81
  • [40] Air quality calculation in subway
    Wu, Wen-Zhong
    You, Shi-Jun
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3699 - 3702