Experimental study on refrigerant charge amount and optimal high pressure of a CO2 heat pump system for an electric bus

被引:0
|
作者
Guo, Yang [1 ]
Yang, Wei [2 ]
Wu, Haimei [2 ]
Li, Tao [2 ]
Chen, Shangmai [1 ]
Jin, Zunlong [1 ]
Deng, Rongbin [2 ]
机构
[1] Zhengzhou Univ, Sch Mech & Power Engn, Zhengzhou, Peoples R China
[2] Zhengzhou Kelin Motor Vehicle Air Conditioning Co, Zhengzhou, Peoples R China
关键词
AIR-CONDITIONING SYSTEM; CARBON-DIOXIDE; PERFORMANCE; R744; VEHICLE; SPACE;
D O I
10.1063/5.0117747
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to investigate the influence of refrigerant charge amount and discharge pressure on a CO2 heat pump system of an electric bus, an experiment setup was built. Tests were carried out in an enthalpy difference chamber to obtain the coefficient of performance and heating capacity of the system at each operating condition. The influence of operation parameters-including refrigerant charge amount, ambient temperature, outlet temperature of gas cooler, and compressor speed-was considered in this experiment. The results showed that the system performance was influenced by charge amount, and the minimum charge amount was 6.8 kg. The charge amount was almost independent of the ambient temperature, but the system performance was more sensitive to the charge amount at low temperatures. The optimal high-pressure relationship for this CO2 heat pump is p(opt) = 0.162T(gc.out) - 0.016T(amb) + 2.668, which was fitted considering both the outlet temperature of the gas cooler and the ambient temperature. Meanwhile, the low-temperature performance test (-22 & DEG;C) showed that this CO2 heat pump system can meet the operation requirements of city buses at low temperature.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Effects of refrigerant charge on performances of transcritical CO2 heat pump water heater
    Jin D.
    Koyama S.
    Xue J.
    Takata N.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2010, 45 (05): : 680 - 684
  • [22] Experimental and theoretical analysis of the optimal high pressure and peak performance coefficient in transcritical CO2 heat pump
    Qin, Xiang
    Zhang, Fan
    Zhang, Dongwei
    Gao, Zhao
    Tang, Songzhen
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [23] Experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater
    Qi, Peng-Cheng
    He, Ya-Ling
    Wang, Xiao-Lin
    Meng, Xiang-Zhao
    APPLIED THERMAL ENGINEERING, 2013, 56 (1-2) : 120 - 125
  • [24] Theoretical and experimental studies on optimum heat rejection pressure for a CO2 heat pump system
    Zhang, X. P.
    Fan, X. W.
    Wang, F. K.
    Shen, H. G.
    APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2537 - 2544
  • [25] A Comprehensive Assessment of the Refrigerant Charging Amount on the Global Performance of a Transcritical CO2-Based Bus Air Conditioning and Heat Pump System
    Song, Yulong
    Xie, Hongsheng
    Yang, Mengying
    Wei, Xiangyu
    Cao, Feng
    Yin, Xiang
    ENERGIES, 2023, 16 (06)
  • [26] Impact of an internal heat exchanger on a transcritical CO2 heat pump under optimal pressure conditions Optimal-pressure performance of CO2 heat pump with IHX
    Oton-Martinez, Ramon A.
    Illan-Gomez, Fernando
    Garcia-Cascales, Jose R.
    Velasco, F. J. S.
    Haddouche, M. Reda
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [27] Experimental study on the heating performance of transcritical CO2 heat pump for electric buses
    Chen, Shangmai
    Yang, Wei
    Wu, Haimei
    Deng, Rongbin
    Li, Tao
    Guo, Yang
    Jin, Zunlong
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (01) : 65 - 74
  • [28] Experimental Study of Optimum Heat Rejection Pressure for a CO2 Heat Pump Water Heater
    Fan Xiaowei
    Zhang Xianping
    Wang Fengkun
    Ma Qiang
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 4, 2010, : 535 - +
  • [29] Experimental study on CO2 secondary throttling heat pump system with dynamic control strategy in electric vehicle
    Teng, Haixu
    Li, Ming
    Liu, Zhikun
    Wang, Jun
    Xiong, Shuangyuan
    Lu, Chunhong
    Song, Zhanzhuo
    Jiang, Yan
    Chang, Wei
    APPLIED THERMAL ENGINEERING, 2025, 268
  • [30] Experimental study of key parameter on transcritical CO2 heat pump system
    Zhu, Zhi-Jiang
    Chen, Guang-Ming
    Tong, Yang
    Tang, Li-Ming
    Lin, Shun-Rong
    Chen, Qi
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2011, 32 (07): : 1103 - 1106