Comparison of an All-Inside Suture Technique With Traditional Pull-Out Suture and Suture Anchor Repair Techniques for Flexor Digitorum Profundus Attachment to Bone

被引:25
|
作者
Chu, Jennifer Y.
Chen, Tony
Awad, Hani A.
Elfar, John
Hammert, Warren C.
机构
[1] Univ Rochester, Med Ctr, Dept Orthopaed Surg & Rehabil, Ctr Musculoskeletal Res, Rochester, NY 14642 USA
[2] Univ Rochester, Med Ctr, Dept Biomed Engn, Rochester, NY 14642 USA
来源
关键词
Flexor digitorum profundus avulsion; flexor digitorum profundus repair; flexor tendon repair; tendon attachment to bone; TENDON REPAIR; BIOMECHANICAL ANALYSIS; ZONE; BUTTON; INJURIES;
D O I
10.1016/j.jhsa.2013.02.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose One goal in repairing zone 1 flexor digitorum profundus (FDP) injuries is to create a tendon-bone construct strong enough to allow early rehabilitation while minimizing morbidity. This study compares an all-inside suture repair technique biomechanically with pull-out suture and double-suture anchor repairs. Methods Repairs were performed on 30 cadaver fingers. In all-inside suture repairs (n = 8), the FDP tendon was attached to bone with two 3-0 Ethibond sutures and tied over the dorsal aspect of distal phalanx. Pull-out suture repairs (n = 8) were performed with 2-0 Prolene suture and tied over a dorsal button. There were 2 suture anchor repair groups: Arthrex Micro Corkscrew anchors preloaded with 2-0 FiberWire suture (n = 7) and Depuy Micro Mitek anchors preloaded with 3-0 Orthocord suture (n = 7). Repair constructs were tested using a servohydraulic materials testing system and loaded until the repair lost 75% of its strength. Results There were no statistically significant differences in tensile stiffness, ultimate load, or work to failure between the repairs. Failure mode was suture stretch and gap formation greater than 2 mm at the repair site for all pull-out suture repairs and for 7 of 8 all-inside suture repairs. Two of the Arthrex Micro Corkscrew repairs and 5 of the Depuy Micro Mitek repairs failed by anchor pull-out. Conclusions This cadaveric biomechanical study showed no difference in tensile stiffness, ultimate load, and work to failures between an all-inside suture repair technique for zone 1 FDP repairs and previously described pull-out suture and suture anchor repair techniques. The all-inside suture technique also has the advantages of avoiding an external button and the cost of anchors. Therefore, it should be considered as an alternative to other techniques. Clinical relevance This study introduces a new FDP reattachment technique that avoids some of the shortcomings of current techniques. (Copyright (C) 2013 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1084 / 1090
页数:7
相关论文
共 50 条
  • [21] A Modified Technique for the Repair of Zone 1 Flexor Digitorum Profundus Tendons Using a Subperiosteal Suture
    Hili, Stephanie
    Valand, Poonam
    Hever, Pennylouise
    Pandya, Ankur N.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 148 (02) : 339E - 341E
  • [22] The modified cross-suture technique for unilateral pulled-out anchor during all-inside meniscal repair
    Jianlong Ni
    Zhibin Shi
    Lihong Fan
    Ning Guo
    Haoyu Wang
    Xiaoqian Dang
    Dichen Li
    BMC Musculoskeletal Disorders, 21
  • [23] All-Inside Repair for a Root Tear of the Medial Meniscus Using a Suture Anchor
    Jung, Yu-Hun
    Choi, Nam-Hong
    Oh, Jong-Seok
    Victoroff, Brian N.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (06): : 1406 - 1411
  • [24] COMPARISON OF INITIAL PULL-OUT STRENGTH OF ARTHROSCOPIC SUTURE AND STAPLE BANKART REPAIR TECHNIQUES
    SHEA, KP
    OKEEFE, RM
    FULKERSON, JP
    ARTHROSCOPY, 1992, 8 (02): : 179 - 182
  • [25] The modified cross-suture technique for unilateral pulled-out anchor during all-inside meniscal repair
    Ni, Jianlong
    Shi, Zhibin
    Fan, Lihong
    Guo, Ning
    Wang, Haoyu
    Dang, Xiaoqian
    Li, Dichen
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [26] Flexor digitorum profundus tendon-to-bone repair:: An ex vivo biomechanical analysis of 3 pullout suture techniques
    Silva, MJ
    Hollstien, SB
    Brodt, MD
    Boyer, MI
    Tetro, AM
    Gelberman, RH
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (01): : 120 - 126
  • [27] A biomechanical assessment of a novel, low-cost all-suture anchor in a flexor digitorum profundus model
    Prasai, Tanup
    Huntington, Lachlan S.
    Ackland, David
    Tham, Stephen K. Y.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2022, 47 (06) : 654 - 656
  • [28] All-inside Arthroscopic Lateral Collateral Ligament Repair for Ankle Instability With a Knotless Suture Anchor Technique
    Vega, Jordi
    Golano, Pau
    Pellegrino, Alexandro
    Rabat, Eduard
    Pena, Fernando
    FOOT & ANKLE INTERNATIONAL, 2013, 34 (12) : 1701 - 1709
  • [29] Effects of suture site or penetration depth on anchor location in all-inside meniscal repair
    Uchida, Ryohei
    Mae, Tatsuo
    Hiramatsu, Kunihiko
    Iuchi, Ryo
    Kinugasa, Kazutaka
    Shino, Konsei
    Yoshikawa, Hideki
    Nakata, Ken
    KNEE, 2016, 23 (06): : 1024 - 1028
  • [30] The "All-Inside" Arthroscopic Brostrom Procedure Augmented With a Proximal Suture Anchor: An Innovative Technique
    Cottom, James M.
    Richardson, Phillip E.
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (02): : 408 - 411