Magnetic and transport eddy-current anomalies in cylinders with core-and-shell regions

被引:28
|
作者
Chen, DX
Pascual, L
Fraga, E
Vazquez, M
Hernando, A
机构
[1] UCM, RENFE, Inst Magnetismo Aplicado, Madrid 28230, Spain
[2] CSIC, Inst Ciencia Mat, Madrid 28230, Spain
关键词
AC permeability; AC impedance; eddy-current anomaly; amorphous wires;
D O I
10.1016/S0304-8853(99)00420-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For a conducting magnetic cylinder of radius r(0), conductivity sigma, and regionally uniform DC permeabilities mu(c), mu(s), and mu(b) in the core, the shell, and the core-shell border at r = r(b) < r(0), the complex AC permeability mu and impedance Z are calculated analytically from the Maxwell equations and the Ohm law. Compared with the results of the classical models with uniform local DC permeability, the low-frequency eddy-current anomaly factors and the high-frequency anomaly behaviors are quantitatively and conceptually explained with respect to different magnetic structures of the cylinder. The results can be used for quantitative studies of domain structures in ferromagnetic wires through AC permeability and impedance measurements and analyses. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:385 / 396
页数:12
相关论文
共 50 条
  • [31] Eddy-current testing with GMR magnetic sensor arrays
    Smith, CH
    Schneider, RW
    Dogaru, T
    Smith, ST
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 406 - 413
  • [32] Corner asymptotics of the magnetic potential in the eddy-current model
    Dauge, Monique
    Dular, Patrick
    Kraehenbuehl, Laurent
    Peron, Victor
    Perrussel, Ronan
    Poignard, Clair
    MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 2014, 37 (13) : 1924 - 1955
  • [33] EXAMINATION OF THE LOCALIZATION PARAMETERS OF AN EDDY-CURRENT TRANSDUCER WITH A CONICAL CORE
    VOLKOV, BI
    AGAFONOV, VA
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1983, 19 (05): : 318 - 322
  • [34] APPLYING EDDY-CURRENT TESTING TO IN-CORE INSTRUMENT THIMBLES
    DOBBENI, D
    NUCLEAR ENGINEERING INTERNATIONAL, 1987, 32 (393): : 62 - 63
  • [35] EDDY-CURRENT FLAW DETECTOR WITH ROTATING CORE IN THE SUPERPOSED TRANSDUCER
    VOLKOV, BI
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1986, 22 (04): : 273 - 277
  • [36] ENERGY CONSIDERATIONS IN THE MAGNETIC (EDDY-CURRENT) STIMULATION OF TISSUES
    NYENHUIS, JA
    MOUCHAWAR, GA
    BOURLAND, JD
    GEDDES, LA
    IEEE TRANSACTIONS ON MAGNETICS, 1991, 27 (01) : 680 - 687
  • [37] TRANSCHEST MAGNETIC (EDDY-CURRENT) STIMULATION OF THE DOG HEART
    BOURLAND, JD
    MOUCHAWAR, GA
    NYENHUIS, JA
    GEDDES, LA
    FOSTER, KS
    JONES, JT
    GRABER, GP
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (02) : 196 - 198
  • [38] EQUIVALENT SCHEMES OF COILS WITH TRANSIENT EDDY-CURRENT LOSSES IN CORE
    MOCANU, CI
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (04): : 1724 - &
  • [39] FERRITE CORE EDDY-CURRENT PROBE MODEL - DESCRIPTION AND VERIFICATION
    SABBAGH, HA
    VERNON, SN
    MATERIALS EVALUATION, 1985, 43 (02) : 184 - 187
  • [40] Study of eddy-current loss reduction by slit in reactor core
    Nogawa, S
    Kuwata, M
    Miyagi, D
    Hayashi, T
    Tounai, H
    Nakao, T
    Takahashi, N
    IEEE TRANSACTIONS ON MAGNETICS, 2005, 41 (05) : 2024 - 2027