Application of Mid-Infrared Spectroscopy for Determination of Insoluble Dietary Fiber Content in Moso Bamboo Shoot

被引:4
|
作者
Yu, Xinjie [2 ,3 ]
Liu, Kangsheng [3 ]
Yu, Xin [2 ]
Wu, Di [1 ]
He, Yong [1 ]
机构
[1] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310029, Zhejiang, Peoples R China
[2] Zhejiang Univ, Ningbo Inst Technol, Ningbo 315100, Zhejiang, Peoples R China
[3] Zhejiang Univ, Dept Mat, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Moso Bamboo Shoot; Insoluble Dietary Fiber; Mid-Infrared Spectroscopy; Partial Least Squares; NEAR-INFRARED SPECTROSCOPY; LEAST-SQUARES REGRESSION; MILK POWDER; NONDESTRUCTIVE MEASUREMENT; EUCALYPTUS-GLOBULUS; MIR SPECTROSCOPY; SOLID WOOD; CELLULOSE; LIGNIN; FRUIT;
D O I
10.1166/sl.2012.1825
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mid-infrared (MIR) spectroscopy was used to measure insoluble dietary fiber content (IDFC) in moso bamboo shoot. A total of 140 moso bamboo shoot samples with various IDFC levels between 0.46% and 0.213% were separated into two groups, as calibration and validation sets. Reference IDFC in moso bamboo shoot was verified using AOAC 991.43 method. MIR absorbance spectra from 400 cm(-1) to 4000 cm(-1) were collected using the calibration and validation sets. Partial least squares (PLS) analysis was performed on the calibration set, and calibration models were developed using original MIR absorbance spectra and its Savitzky-Golay first derivative spectra. Standard error of calibration (SEC) and coefficient of multiple determinations (R-2) of the calibration models were calculated to select the best model. Savitzky-Golay first derivative spectra calibration model was found to be the best, with the lowest SEC of 0.007 and highest R-2 of 0.968. This calibration model was then used to predict IDFC in moso bamboo shoots from the validation set. Predicted and reference IDFC values were compared. Relative percent deviation (RPD) and standard error of prediction (SEP) were calculated to validate the goodness of fit of the model. The Savitzky-Golay first derivative spectra calibration model gave an RPD of 3.710 with a corresponding SEP of 0.011, which indicated that MIR spectroscopy technique coupled with PLS was a rapid and accurate way for determination of IDFC in moso bamboo shoot.
引用
收藏
页码:600 / 607
页数:8
相关论文
共 50 条
  • [41] An application of near-infrared and mid-infrared spectroscopy to the study of selected minerals
    Frost, Ray L.
    Reddy, B. Jagannadha
    Keeffe, Eloise C.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2010, 165 (03): : 193 - 205
  • [42] Application of Mid-Infrared Wavelength Tunable Laser in Glucose Determination
    Yu Song-lin
    Li Da-chao
    Zhong Hao
    Sun Chang-yue
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (04) : 972 - 976
  • [43] Nitrous Oxide Isotope Ratio Determination by Mid-infrared Laser Spectroscopy
    Waechter, Helen
    Sigrist, Markus W.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 516 - 517
  • [44] Mid-infrared spectroscopy coupled with chemometrics for quantitative determination of biomaterial activity
    Cao, Hao
    Gu, Youlin
    Hu, Yihua
    Wang, Xinyu
    Ding, Wanying
    Chen, Guolong
    Chen, Xi
    He, Haihao
    OPTIK, 2023, 281
  • [45] Validation of chemometric models for the determination of deoxynivalenol on maize by mid-infrared spectroscopy
    G. Kos
    H. Lohninger
    R. Krska
    Mycotoxin Research, 2003, 19 (2) : 149 - 153
  • [46] Data for the Determination of Total Carbon in Biosolids using MID-Infrared Spectroscopy
    Albuquerque, N.
    Meehan, B.
    Hughes, J.
    Surapaneni, A.
    DATA IN BRIEF, 2020, 30
  • [47] Recent Advances in the Determination of Milk Adulterants and Contaminants by Mid-Infrared Spectroscopy
    Ceniti, Carlotta
    Spina, Anna Antonella
    Piras, Cristian
    Oppedisano, Francesca
    Tilocca, Bruno
    Roncada, Paola
    Britti, Domenico
    Morittu, Valeria Maria
    FOODS, 2023, 12 (15)
  • [48] Direct determination of nitrate concentration in environmental systems by mid-infrared spectroscopy
    Linker, R
    Shaviv, A
    Shmulevich, I
    LAND AND WATER MANAGEMENT: DECISION TOOLS AND PRACTICES, VOLS 1 AND 2, 2004, : 945 - 953
  • [49] Nitrate determination using anion exchange membrane and mid-infrared spectroscopy
    Linker, Raphael
    Shaviv, Avi
    APPLIED SPECTROSCOPY, 2006, 60 (09) : 1008 - 1012
  • [50] Determination of SARA fractions in asphalts by mid-infrared spectroscopy and multivariate calibration
    Li, Jin
    Xing, Xinyuan
    Hou, Xiangdao
    Wang, Tao
    Wang, Jiayu
    Xiao, Feipeng
    MEASUREMENT, 2022, 198