Determination of pore diameter and molecular weight cut-off of hydrogel-membrane liquid-core capsules for immunoisolation

被引:27
|
作者
Dembczynski, R [1 ]
Jankowski, T [1 ]
机构
[1] Acad Agr Poznan, Dept Biotechnol & Food Microbiol, PL-61623 Poznan, Poland
关键词
alginate/starch capsules; inverse size exclusion chromatography; pore size; molecular weight cut-off; immunoisolation;
D O I
10.1163/156856201753252552
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The exclusion limit expressed as the largest pore size of capsules composed of hydrogel Ca-alginate membrane and hydroxy-propyl-ammonium starch liquid core considered as the immunoprotective system has been determined by means of inverse size exclusion chromatography with dextran molecular weight standards. The exclusion limits of the capsules were not influenced by the change of starch concentration in the core solution from 4 to 6% but were influenced by the change in alginate concentration in the membrane from 0.5 to 1.0%, causing the membranes to be less permeable. It was found that the diameter of the largest pores in hydrogel membranes was in the range 7.2-8.0 nm. Based on the relationship between solute size and its molecular weight, the capsules had an approximate exclusion limit of 21-25 kD for dextran and 78-103 kD for protein, which is sufficient to block the antibodies penetrating through the membrane.
引用
收藏
页码:1051 / 1058
页数:8
相关论文
共 41 条
  • [1] Characterisation of small molecules diffusion in hydrogel-membrane liquid-core capsules
    Dembczynski, R
    Jankowski, T
    BIOCHEMICAL ENGINEERING JOURNAL, 2000, 6 (01) : 41 - 44
  • [2] Modelling and simulation of a bienzymatic reaction system co-immobilised within hydrogel-membrane liquid-core capsules
    Blandino, A
    Macías, M
    Cantero, D
    ENZYME AND MICROBIAL TECHNOLOGY, 2002, 31 (04) : 556 - 565
  • [3] Nanotechnological method to control the molecular weight cut-off and/or pore diameter of organic-inorganic composite membrane
    Okazaki, I
    Ohya, H
    Semenova, SI
    Kikuchi, S
    Aihara, M
    Negishi, Y
    JOURNAL OF MEMBRANE SCIENCE, 1998, 141 (01) : 65 - 74
  • [4] Formation of liquid-core capsules having a thin hydrogel membrane: liquid pearls
    Bremond, Nicolas
    Santanach-Carreras, Enric
    Chu, Liang-Yin
    Bibette, Jerome
    SOFT MATTER, 2010, 6 (11) : 2484 - 2488
  • [5] Can sonication enhance release from liquid-core capsules with a hydrogel membrane?
    Zhang, Liguo
    Salsac, Anne-Virginie
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2012, 368 : 648 - 654
  • [6] In vivo biocompatibility evaluation of cellulose macrocapsules for islet immunoisolation:: Implications of low molecular weight cut-off
    Risbud, MV
    Bhargava, S
    Bhonde, RR
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01): : 86 - 92
  • [7] Study on molecular weight cut-off of the anaerobic ultrafiltration membrane bioreactor
    He, Yiliang
    Li, Chunjie
    Wu, Zhichao
    Gu, Guowei
    Zhongguo Jishui Paishui/China Water & Wastewater, 1999, 15 (09): : 10 - 12
  • [8] High cut-off membrane: evaluation of pore collapse and the synergistic effect of low and high molecular weight polyvinylpyrrolidone
    Dehghan, Rahim
    Barzin, Jalal
    JOURNAL OF POLYMER RESEARCH, 2021, 28 (03)
  • [9] High cut-off membrane: evaluation of pore collapse and the synergistic effect of low and high molecular weight polyvinylpyrrolidone
    Rahim Dehghan
    Jalal Barzin
    Journal of Polymer Research, 2021, 28
  • [10] A convenient method for the determination of molecular weight cut-off of ultrafiltration membranes
    Cunyu Li
    Yun Ma
    Hongyang Li
    Guoping Peng
    ChineseJournalofChemicalEngineering, 2017, 25 (01) : 62 - 67