Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis

被引:41
|
作者
Saikko, V
Calonius, O
Keränen, J
机构
[1] Helsinki Univ Technol, Dept Mech Engn, FIN-02015 Helsinki, Finland
[2] Tampere Univ Technol, Dept Mat Engn, FIN-33101 Tampere, Finland
关键词
slide track; aspect ratio; polyethylene wear; total hip prosthesis; pin-on-disk;
D O I
10.1002/jbm.b.20043
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prosthetic joints appear to show a strong relationship between the type of relative motion and wear, requiring careful consideration in the design of wear simulators. This relationship was studied with a 12-station pin-on-disk device, specifically adapted for the wear simulation of prosthetic hip joints. Each station had a unique motion, characterized by the so-called slide track, the track of the pin on the disk. The slide track shapes included 10 ellipses, their aspect ratio (AR) varying from 1.1 to 11.0, and a circle and a straight line as extreme cases. Hence for the first time in hip wear simulation, the motion was systematically varied over a wide range. Conventional UHMWPE pins were tested against polished CoCr disks in diluted calf serum three times for 3 million cycles. Below the AR value of 5.5, the polyethylene wear factor and wear mechanisms agreed with clinical observations. Above this value, the wear factor decreased to unrealistically low values, and the wear surface topography differed from that of retrieved acetabular cups. The wear particles, however, were similar to those isolated from periprosthetic tissues, irrespective of the AR value. In conclusion, it is recommended that the AR value be kept well below the critical point of 5.5. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [21] Experimental and Computational Thermal Modeling of In Vitro Pin-on-Disk Tests of Ultra High Molecular Weight Polyethylene
    Lewicki, Kathleen A.
    Van Citters, Douglas W.
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2016, 138 (04):
  • [22] Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: a review of key influences
    McGloughlin, TM
    Kavanagh, AG
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H4) : 349 - 359
  • [23] Wear mechanisms of untreated and gamma irradiated ultra-high molecular weight polyethylene for total joint replacements
    Zhou, J
    Komvopoulos, K
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2005, 127 (02): : 273 - 279
  • [24] Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components
    Spector, M
    Ries, MD
    Bourne, RB
    Sauer, WS
    Long, M
    Hunter, G
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A : 80 - 86
  • [25] The effect of adding calcium stearate on wear-resistance of ultra-high molecular weight polyethylene
    Panin, C., V
    Kornienko, L. A.
    Suan, Nguyen T.
    Ivanova, L. R.
    Poltaranin, M. A.
    OIL AND GAS ENGINEERING (OGE-2015), 2015, 113 : 490 - 498
  • [26] Effect of counterface surface roughness on the friction and wear properties of ultra-high molecular weight polyethylene
    Li, Qiang
    Leng, Yong-Xiang
    Xie, Dong
    Huang, Nan
    Gongneng Cailiao/Journal of Functional Materials, 2010, 41 (06): : 931 - 934
  • [27] Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding
    Saikko, V.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H7) : 723 - 731
  • [28] Backside wear of modular ultra-high molecular weight polyethylene tibial inserts
    Conditt, MA
    Ismaily, SK
    Alexander, JW
    Noble, PC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05): : 1031 - 1037
  • [29] Comparative wear tests of ultra-high molecular weight polyethylene and cross-linked polyethylene
    Harsha, A. P.
    Joyce, Tom J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 600 - 608
  • [30] The effect of cup inclination and wear on the contact mechanics and cement fixation for ultra high molecular weight polyethylene total hip replacements
    Hua, Xijin
    Wroblewski, B. Michael
    Jin, Zhongmin
    Wang, Ling
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) : 318 - 325