Comparison of three methods of diagnosis of plasma unmeasured anions in critically ill patients

被引:0
|
作者
Lautrette, A. [1 ,2 ]
Fejjal, M. [1 ]
Aithssain, A. [1 ]
Phan, T-N [1 ]
Caillot, N. [1 ]
Fogli, A. [2 ,3 ]
Souweine, B. [1 ,2 ]
机构
[1] CHU Clermont Ferrand, Serv Reanimat, Pole REUNNIRH, Clermont Ferrand, France
[2] Univ Clermont 1, UFR Med, Clermont Ferrand, France
[3] CHU Clermont Ferrand, Serv Biochim, Clermont Ferrand, France
关键词
Intensive care units; Acid-base imbalance; Plasma; INTENSIVE-CARE-UNIT; ACID-BASE-DISORDERS; FENCL-STEWART APPROACH; METABOLIC-ACIDOSIS; EXCESS; GAP; PARAMETERS; MORTALITY; FAILURE; SEPSIS;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The measurement of plasma unmeasured anions (PUA) is paramount in assessing metabolic acid base disorders. The aim of this study was to compare the accuracy of three methods in diagnosing abnormal PUA values: standard base excess (SBE), the albumin corrected anion gap (AG(c)), and the Stewart-Figge approach, based on unidentified anions (XA(c)(-)). Methods. Acid-base variables were prospectively collected in ICU patients admitted January-September 2008. Whatever the method, PUA values measured two standard deviations above or below the mean of those in control subjects were considered as abnormal. Results. Of the 205 consecutives patients included, 179 had an abnormal PUA value. The accuracy of AGc and XA(c)(-) in diagnosing abnormal PUA values was comparable (AUC: 0.89 +/- 0.03 and 0.89 +/- 0.03, P=0.82) but greater than that of SBE (0.67 +/- 0.06, P<0.001 and P<0.001, respectively). Of the high PUA values (n=161), 96% were diagnosed by XA(c)(-), 88% by AGc (P<0.01) and 48% by SBE (P<0.001). Hyperlactatemia (n=111) was diagnosed equally by AGc and XA(c)(-), (81% and 86%, P=0.37) but less by SBE (50%, P<0.001 and P<0.001, respectively). High PUA not associated with hyperlactatemia (N.=61) was more frequently diagnosed by XA(c)(-) (97%) than by AGc (84%, P=0.03). Conclusion. In ICU patients, AGc and the Stewart-Figge approach should be preferred over SBE for diagnosing abnormal PUA values and predicting hyperlactatemia. The Stewart-Figge approach based on unidentified anions, is the most efficient in diagnosing high PUA values not associated with hyperlactatemia.
引用
收藏
页码:1164 / 1172
页数:9
相关论文
共 50 条
  • [11] COMPARISON OF THREE NONINVASIVE HEMODYNAMIC MONITORING METHODS IN CRITICALLY ILL PEDIATRIC PATIENTS
    Chaiyakulsil, Chanapai
    Anantasit, Nattachai
    Katanyuwong, Poomiporn
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 110 - 110
  • [12] Anion gap, anion gap corrected for albumin, base deficit and unmeasured anions in critically ill patients: Implications on the assessment of metabolic acidosis and the diagnosis of hyperlactatemia
    Chawla L.S.
    Shih S.
    Davison D.
    Junker C.
    Seneff M.G.
    BMC Emergency Medicine, 8 (1)
  • [13] Comparison of three severity scores for critically ill cancer patients
    Peter Schellongowski
    Michael Benesch
    Thomas Lang
    Friederike Traunmüller
    Christian Zauner
    Klaus Laczika
    Gottfried J. Locker
    Michael Frass
    Thomas Staudinger
    Intensive Care Medicine, 2004, 30 : 430 - 436
  • [14] Comparison of three severity scores for critically ill cancer patients
    Schellongowski, P
    Benesch, M
    Lang, T
    Traunmüller, F
    Zauner, C
    Laczika, K
    Locker, GJ
    Frass, M
    Staudinger, T
    INTENSIVE CARE MEDICINE, 2004, 30 (03) : 430 - 436
  • [15] Comparison of three methods to estimate plasma bicarbonate in critically ill patients: Henderson-Hasselbalch, enzymatic, and strong-ion-gap
    Story, DA
    Poustie, S
    Bellomo, R
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (06) : 585 - 590
  • [16] Estimating unmeasured anions in critically ill patients: Anion-gap, base-deficit, and strong-ion-gap
    Story, DA
    Poustie, S
    Bellomo, R
    ANAESTHESIA, 2002, 57 (11) : 1109 - 1114
  • [17] Comparison of two methods for cardiac output measurement in critically ill patients
    Saraceni, E.
    Rossi, S.
    Persona, P.
    Dan, M.
    Rizzi, S.
    Meroni, M.
    Ori, C.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (05) : 690 - 694
  • [18] COMPARISON OF THE METHODS FOR CLASSIFICATION OF OBSERVATIONS IN PREDICTING COMPLICATIONS IN CRITICALLY ILL PATIENTS
    Ivanchuk, M. A.
    Malyk, I. V.
    CYBERNETICS AND SYSTEMS ANALYSIS, 2015, 51 (02) : 303 - 312
  • [19] Comparison of three non-invasive hemodynamic monitoring methods in critically ill children
    Chaiyakulsil, Chanapai
    Chantra, Marut
    Katanyuwong, Poomiporn
    Khositseth, Anant
    Anantasit, Nattachai
    PLOS ONE, 2018, 13 (06):
  • [20] COMPARISON OF INSULIN INFUSION METHODS IN CRITICALLY ILL PATIENTS: BASAL/BOLUS AND MULTIPLIER
    Zechmeister, Carrie
    Fesko, Amanda
    Leis, Rachel
    Rohaley, Deidre
    CRITICAL CARE MEDICINE, 2014, 42 (12)