Objectives: CBCT systems, with their high precision 3D reconstructions, 1:1 images and accuracy in locating cephalometric landmarks, allows us to evaluate measurements from craniofacial structures, so enabling us to replace the anthropometric methods or bidimensional methods used until now. The aims are to analyse cranio-facial relationships in a sample of patients who had previously undergone a CBCT and create a new 3D cephalometric method for assessing and measuring patients. Study Design: 90 patients who had a CBCT (i-Cat (R)) as a diagnostic register were selected. 12 cephalometric landmarks on the three spatial planes (X, Y, Z) were defined and 21 linear measurements were established. Using these measurements, 7 triangles were described and analysed. With the sides of the triangles: (CdR-Me-CdL); (FzR-Me-FzL); (GoR-N-GoL); and the Gl-Me distance, the ratios between them were analysed. In addition, 4 triangles in the mandible were measured (body: GoR-DB-Me and GoL-DB-Me and ramus: KrR-CdR-GoR and KrL-CdL-GoL). Results: When analyzing the sides of the CdR-Me-CdL triangle, it was found that the 69.33% of the patients could be considered symmetric. Regarding the ratios between the sides of the following triangles: CdR-Me-CdL, FzR-Me-FzL, GoR-N-GoL and the Gl-Me distance, it was found that almost all ratios were close to 1:1 except between the CdR-CdL side with respect the rest of the sides. With regard to the ratios of the 4 triangles of the mandible, it was found that the most symmetrical relationships were those corresponding to the sides of the body of the mandible and the most asymmetrical ones were those corresponding to the base of such triangles. Conclusions: A new method for assessing cranio-facial relationshps using CBCT has been established. It could be used for diverse purposes including diagnosis and treatment planning.
引用
收藏
页码:E706 / E713
页数:8
相关论文
共 50 条
  • [41] 3D versus 4D cone beam computed tomography for lipiodolnguided radiotherapy of hepatocellular carcinomas
    Chan, M. K. H.
    Chiang, A. C. C.
    Lee, F. A. S.
    Leung, R. W. K.
    Wong, M. Y. P.
    Law, G. M. L.
    Lee, K. H.
    Tung, S. Y.
    Lee, V. W. Y.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S817 - S817
  • [42] Photoacoustic tomography versus cone-beam computed tomography versus micro-computed tomography: Accuracy of 3D reconstructions of human teeth
    Schneider, Sonja Jasmin Maria
    Hoehne, Christian
    Schneider, Martin
    Schmitter, Marc
    PLOS ONE, 2022, 17 (12):
  • [43] Cone-beam computer tomography reconstruction 3D
    Moura, C
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S229 - S229
  • [44] 3D MTF estimation using sphere phantoms for cone-beam computed tomography systems
    Lee, Changwoo
    Song, Hoon-dong
    Baek, Jongduk
    MEDICAL PHYSICS, 2020, 47 (07) : 2838 - 2851
  • [45] Complex 3D scan trajectories for industrial cone-beam computed tomography using a hexapod
    Butzhammer, Lorenz
    Hausotte, Tino
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (10)
  • [46] Development and characterization of a 3D cone beam tomography system
    Sarkar, PS
    Sinha, A
    Kashyap, Y
    More, MR
    Godwal, BK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 524 (1-3): : 377 - 384
  • [47] Comparative evaluation of the accuracy of linear measurements between cone beam computed tomography and 3D microtomography
    Mangione, Francesca
    Meleo, Deborah
    Talocco, Marco
    Pecci, Raffaella
    Pacifici, Luciano
    Bedini, Rossella
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2013, 49 (03): : 261 - 265
  • [48] Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols
    Forst D.
    Nijjar S.
    Flores-Mir C.
    Carey J.
    Secanell M.
    Lagravere M.
    Progress in Orthodontics, 15 (1) : 69
  • [49] Evaluation of 3D Airway Imaging of Obstructive Sleep Apnea with Cone-beam Computed Tomography
    Ogawa, Takumi
    Enciso, Reyes
    Memon, Ahmed
    Mah, James K.
    Clark, Glenn T.
    MEDICINE MEETS VIRTUAL REALITY 13: THE MAGICAL NEXT BECOMES THE MEDICAL NOW, 2005, 111 : 365 - 368
  • [50] 3D tooth segmentation in cone-beam computed tomography images using distance transform
    Kakehbaraei, Somayeh
    Arvanaghi, Roghayyeh
    Seyedarabi, Hadi
    Esmaeili, Farzad
    Zenouz, Ali Taghavi
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 79