Indoor Thermal Comfort: A Study at Malaysian Automotive Industry

被引:0
|
作者
Ismail, A. R. [1 ]
Mat, S. [1 ]
Jusoh, N. [1 ]
Rahman, M. N. Ab. [1 ]
Sopian, K. [1 ]
Othman, I. M. S. [1 ]
Tahir, M. M. [1 ]
Deros, B. M.
机构
[1] Univ Kebangsaan Malaysia, SERI, Ukm Bangi 43600, Malaysia
关键词
thermal; comfort; temperature; PPD; PMV;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study is to determine the thermal comfort among worker at Malaysian automotive industry. One automotive parts assembly factory had been chosen as a subject for the study. The human subjects for the study constitute operators at tire receiving section of the factory. The environment examined was the relative humidity (%), WBGT (C-0), Air temperature () and Radiant Temperature () of the surrounding workstation area. The environmental factors were measured using Babuc apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then thermal comfort of the workers were assessed by using ASHRAE Thermal sensation scale by using Predicted Mean Vote (PMV) which has been proposed earlier by Fanger (1970). Further Predicted percentage dissatisfied (PPD) is used to estimate the thermal comfort satisfaction of the occupant. Finally the PPD versus PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. The study reveals that 54.03 % of the workers population at the workstation are likely to be satisfied with thermal comfort at this station.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条
  • [31] A Pilot Study on the Indoor Thermal Comfort of the "Wind-Rain" House
    Su, Bin
    INTERNATIONAL JOURNAL OF VENTILATION, 2011, 10 (01) : 79 - 87
  • [32] Study of the thermal performance of a new type of floor heating and resulting indoor thermal comfort
    Liu, Chang
    Zhang, Zhigang
    Dong, Haochuan
    Liu, Xueli
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (04) : 504 - 513
  • [33] Study of indoor air quality and thermal comfort in a room with displacement ventilation
    Li, Y
    Wang, X
    Li, J
    Sun, Y
    Jia, H
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1027 - 1032
  • [34] Indoor Thermal Comfort of Pregnant Women in Hospital: A Case Study Evidence
    Fabbri, Kristian
    Gaspari, Jacopo
    Vandi, Laura
    SUSTAINABILITY, 2019, 11 (23)
  • [35] A study of indoor air pollutants and thermal comfort in high school classrooms
    Li, Y
    Liu, J
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 389 - 393
  • [36] Study on the indoor thermal comfort of cave dwellings in cold areas of China
    Cheng, Xiaoyue
    Jing, Shenglan
    Yang, Yan
    Xu, Wei
    Wang, Zhipeng
    Lan, Zhiping
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [37] A field study of thermal inertia of roofs and its influence on indoor comfort
    D'Orazio, Marco
    Di Perna, Costanzo
    Di Giuseppe, Elisa
    JOURNAL OF BUILDING PHYSICS, 2014, 38 (01) : 50 - 65
  • [38] Thermal Comfort Modeling of Cooled Automotive Seats
    Rutkowski, Paul M.
    SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS, 2010, 3 (01): : 523 - 532
  • [39] Review study of developing an integrated TQM with LM framework model in Malaysian automotive industry
    Faculty of Mechanical Engineering, Universiti Teknologi MARA , Shah Alam, Malaysia
    TQM J., 5 (399-417):
  • [40] Evaluation of the thermal comfort in workplaces-a study in the metalworking industry
    Talaia, M.
    Meles, B.
    Teixeira, L.
    OCCUPATIONAL SAFETY AND HYGIENE, 2013, : 473 - 477