Dose Perturbations at Heterogeneous Interfaces in Radiotherapy - an EGSnrc based Monte Carlo Investigation

被引:0
|
作者
Ahmad, Muhammad Adeel [1 ]
Ahmed, Shahbaz [1 ]
Kakakhel, Muhammad Basim [1 ]
Rehman, Shakeel Ur [1 ]
Mirza, Sikander M. [1 ]
机构
[1] PIEAS, DPAM, Islamabad, Pakistan
来源
2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET) | 2016年
关键词
interface dosimetry; air cavity; Lung heterogeneity; backscatter dose factor; Forward-scatter dose factor; EGSnrc; DOSXYZnrc; BEAMnrc; ATOMIC-NUMBER INTERFACES; X-RAY-BEAMS; PHOTON BEAMS; HIGH-ENERGY; AIR CAVITIES; RADIATION; CODE; MEDIA;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Radiotherapy dose computation in the presence of tissue heterogeneities presents a challenge for the treatment planning system (TPS). This study presents a Monte Carlo (MC) investigation of dose perturbation due to various kinds of heterogeneities (soft tissue interfaces with bone, air, lung and metallic implants) for a range of clinically useful photon energies and field sizes. EGSnrc MC radiation transport code has been used for linear accelerator head modeling and phantom dose calculations. Dose perturbations were quantified in terms of forward- and backscatter factors as well as inside the heterogeneity of low densities for various field sizes including 5 x 5 cm(2), 10 x 10 cm(2) and 15 x 15 cm(2). For lung heterogeneity, both under-dosage and over-dosage has been assessed in relation to the field sizes and energies. These simulations confirm under-dosage in the case of lung heterogeneity for small field sizes, which increases with the energy. However, lung tissues reflect an overdose with smaller energies and larger field sizes.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] A Monte Carlo dose calculation tool for radiotherapy treatment planning
    Ma, CM
    Li, JS
    Pawlicki, T
    Jiang, SB
    Deng, J
    Lee, MC
    Koumrian, T
    Luxton, M
    Brain, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1671 - 1689
  • [42] Study of Dose Calculation Using Monte Carlo Method in Radiotherapy
    Gao, C.
    Chi, Z.
    Liu, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy
    Gagne, I. M.
    Ansbacher, W.
    Zavgorodni, S.
    Popescu, C.
    Beckham, W. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24): : 7167 - 7185
  • [44] Absolute dose calculations for Monte Carlo simulations of radiotherapy beams
    Popescu, IA
    Shaw, CP
    Zavgorodni, SF
    Beckham, WA
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (14): : 3375 - 3392
  • [45] GPU Accelerated Monte Carlo Simulation for Radiotherapy Dose Calculation
    Zhuge, Y.
    Xie, H.
    Cheng, J.
    Miller, R. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S702 - S702
  • [46] Dose calculation of dynamic trajectory radiotherapy using Monte Carlo
    Manser, Peter
    Frauchiger, Daniel
    Frei, Daniel
    Volken, Werner
    Terribilini, Dario
    Fix, Michael K.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (01): : 31 - 38
  • [47] Monte Carlo simulation on heterogeneous phantom and physical dose calculation on heterogeneous organ
    Chemingui, F. Z.
    Benrachi, F.
    Bali, M. S.
    JOURNAL OF NEW TECHNOLOGY AND MATERIALS, 2019, 9 (02) : 51 - 56
  • [48] Proton dose in heterogeneous lung tissue - A Monte Carlo study
    Bues, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2485 - 2485
  • [49] RADIOTHERAPY DOSE PRESCRIPTION BASED ON MONTE CARLO SIMULATIONS SHOULD USE DOSE TO MEDIUM RATHER THAN DOSE TO WATER
    Ma, C. M. C.
    Li, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S523 - S523
  • [50] Investigation of the Attila Deterministic Solver as a Supplement to Monte Carlo for Calculating Out-Of-Field Radiotherapy Dose
    Mille, M.
    Lee, C.
    Failla, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3487 - 3487