Low-profile Zenith Alpha™ Thoracic Stent Graft Modification Using Preloaded Wires for Urgent Repair of Thoracoabdominal and Pararenal Abdominal Aortic Aneurysms

被引:26
|
作者
Han, Sukgu M. [1 ]
Tenorio, Emanuel R. [2 ]
Mirza, Aleem K. [2 ]
Zhang, Louis [1 ]
Weiss, Salome [2 ,3 ]
Oderich, Gustavo S. [2 ]
机构
[1] Univ Southern Calif, Div Vasc Surg & Endovasc Therapy, Los Angeles, CA 90007 USA
[2] Mayo Clin, Div Vasc & Endovasc Surg, Rochester, MN USA
[3] Univ Bern, Dept Cardiovasc Surg, Inselspital, Bern, Switzerland
关键词
MODIFIED ENDOVASCULAR GRAFTS; REPORTING STANDARDS; OUTCOMES;
D O I
10.1016/j.avsg.2020.02.022
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of this study is to describe a modification technique using the low-profile Cook Zenith AlphaTM thoracic stent graft, and addition of a preloaded wire system, for urgent repair of pararenal (PRA) and thoracoabdominal (TAAA) aortic aneurysms. Methods: We analyzed 20 consecutive patients who underwent urgent physician modified endograft repair (PMEG) of PRA and TAAA at 2 institutions. The low-profile Cook Zenith Alpha Thoracic stent graft was modified in accordance with each specific patient anatomic character-istics. End points were technical success, 30-day mortality, and major adverse events (MAEs). Results: Technical success was achieved in all patients (100%). A total of 76 renal-mesenteric arteries were incorporated by fenestrations (70%) or directional branches (30%) with an average of 3.7 +/- 0.6 vessels per patient. There were 6 different types of stent configuration. The most common design consisted of 4 fenestrations (9 patients, 45%). The average of modification time was 110 +/- 27 minutes. Total procedure time (including the time for open component) was 242 +/- 75 minutes. There was no death within the first 30 days or hospital stay. MAEs occurred in 10 patients (50%). The most common MAEs were acute kidney injury (by Risk, Injury, and Failure; and Loss; and End-stage kidney disease criteria) in 6 patients (30%), esti-mated blood loss >1 L, respiratory failure requiring reintubation in 2 patients (10%) each, and paraplegia and ischemic colitis in 1 patient (5%) each. One patient (5%) required temporary, new-onset dialysis. Conclusions: PMEG using low-profile Zenith Alpha thoracic stent graft was safe with no early mortality and acceptable early morbidity.
引用
收藏
页码:14 / 25
页数:12
相关论文
共 50 条
  • [1] Evaluation of the Zenith low-profile abdominal aortic aneurysm stent graft
    Sobocinski, Jonathan
    Briffa, Florent
    Holt, Peter J.
    Gonzalez, Teresa Martin
    Spear, Rafaelle
    Azzaoui, Richard
    Maurel, Blandine
    Haulon, Stephan
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (04) : 841 - 847
  • [2] New Low-Profile Zenith Alpha Stent-Graft for the Treatment of Thoracic Aortic Disease: A Real Breakthrough?
    Tolenaar, Jip L.
    de Vries, Jean Paul P. M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (02) : 160 - 162
  • [3] Endovascular repair for blunt thoracic aortic injury using the Zenith Alpha low-profile device
    Starnes, Benjamin W.
    Dwivedi, Amit J.
    Giglia, Joseph S.
    Woo, Karen
    Yeh, Chyon
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (06) : 1495 - +
  • [4] Stent graft modification with mini-cuff reinforced fenestrations for urgent repair of thoracoabdominal aortic aneurysms
    Oderich, Gustavo S.
    Fatima, Javairiah
    Gloviczki, Peter
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (05) : 1522 - 1526
  • [5] Outcomes of Standard Versus Low-Profile Fenestrated-Branched Endovascular Aortic Repair for Pararenal and Thoracoabdominal Aneurysms
    Mirza, Aleem K.
    Tenorio, Emanuel R.
    Karkkainen, Jussi M.
    Mendes, Bernardo C.
    DeMartino, Randall R.
    Gloviczki, Peter
    Macedo, Thanila A.
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E86 - E86
  • [6] Early results of a low-profile stent-graft for thoracic endovascular aortic repair
    El Beyrouti, Hazem
    Lescan, Mario
    Doemland, Marco
    Mustafi, Migdat
    Jungmann, Florian
    Jorg, Tobias
    Halloum, Nancy
    Dorweiler, Bernhard
    PLOS ONE, 2020, 15 (11):
  • [7] Endo vascular stent graft repair of abdominal and thoracic aortic aneurysms
    Bayramoglu, Zehra
    Sanisoglu, Ilhan
    Onat, Levent
    Caynak, Baris
    Sagbas, Ertan
    Ozgen, Hakan
    Akpinar, Belhan
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2012, 12 (01): : 84 - 86
  • [8] Technical aspects of repair of juxtarenal abdominal aortic aneurysms using the Zenith fenestrated endovascular stent graft
    Oderich, Gustavo S.
    Correa, Mateus P.
    Mendes, Bernardo C.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (05) : 1456 - 1461
  • [9] Endovascular stent-graft repair of pararenal and type IV thoracoabdominal aortic aneurysms with adjunctive visceral reconstruction
    Fulton, JJ
    Farber, MA
    Marston, WA
    Mendes, R
    Mauro, MA
    Keagy, BA
    JOURNAL OF VASCULAR SURGERY, 2005, 41 (02) : 191 - 198
  • [10] Long-term Results of Thoracic Endovascular Aortic Repair Using a Low-Profile Stent-Graft
    Beropoulis, Efthymios
    Fazzini, Stefano
    Austermann, Martin
    Torsello, Giovanni B.
    Damerau, Sarah
    Torsello, Giovanni Federico
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (01) : 56 - 62