Numerical simulation of endovenous laser treatment of the incompetent great saphenous vein with external air cooling

被引:11
|
作者
Marqa, Mohamad Feras [1 ]
Mordon, Serge [1 ]
Hernandez-Osma, Esteban [2 ]
Trelles, Mario [2 ]
Betrouni, Nacim [1 ]
机构
[1] Univ Lille Nord France, Lille Univ Hosp, INSERM, U703, F-59120 Lille, France
[2] Fdn Antoni de Gimbernat, Inst Med Vilafortuny, Tarragona, Spain
关键词
Endovenous laser; Saphenous vein; Finite element method; Air cooling; 940-NM DIODE-LASER; COLD-AIR; MONTE-CARLO; SCATTERING; ABLATION; MODEL; TRANSPORT; THERAPY; 980-NM; DAMAGE;
D O I
10.1007/s10103-012-1141-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Endovenous laser treatment (ELT) has been proposed as an alternative in the treatment of reflux of the great saphenous vein. Before the procedure, peri-saphenous subcutaneous tumescent saline solution infiltration is usually performed. However, diffusion of this tumescent fluid is rapidly observed and can potentially reduce the efficacy as a heat sink. External skin cooling with cold air was proposed as an alternative solution. The objective of this study is to compare endovenous laser treatment without and with air cooling by realistic numerical simulations. An optical-thermal damage model was formulated and implemented using finite element modeling. The general model simulated light distribution using the diffusion approximation of the transport theory, temperature rise using the bioheat equation, and laser-induced injury using the Arrhenius damage model. Parameters, used in clinical procedures, were considered: power, 15 W; pulse duration, 1 s; fiber pull back, 3-mm increments every second; cold air applied in continuous mode during ELT; and no tumescent anesthesia. Simulations were performed for vein locations at 5, 10, and 15 mm in depth, with and without air cooling. For a vein located at 15 mm in depth, no significant difference was observed with and without cooling. For a vein located at 10 mm in depth, surface temperature increase up to 45 A degrees C is observed without cooling. For a vein located at 5 mm, without cooling, temperature increase leads to irreversible damage of dermis and epidermis. Conversely, with air cooling, surface temperature reaches a maximum of 38 A degrees C in accordance with recordings performed on patients. ELT of the incompetent great saphenous vein with external air cooling system is a promising therapy technique. Use of cold air on the skin continuously flowing in the area of laser shot decreased significantly the heat extent and the thermal damage in the perivenous tissues and the skin.
引用
收藏
页码:833 / 844
页数:12
相关论文
共 50 条
  • [21] Mechanochemical endovenous ablation for the treatment of great saphenous vein insufficiency
    van Eekeren, Ramon R. J. P.
    Boersma, Doeke
    Holewijn, Suzanne
    Werson, Debora A. B.
    de Vries, Jean Paul P. M.
    Reijnen, Michel M. J. P.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (03) : 282 - 288
  • [22] Endovenous laser therapy of the incompetent great saphenous vein [Trattamento endovascolare dell'insufficienza della vena grande safena mediante laser]
    Petronelli S.
    Prudenzano R.
    Mariano L.
    Violante F.
    La radiologia medica, 2006, 111 (1) : 85 - 92
  • [23] Comparative study between endovenous laser ablation (EVLA) with 1940 nm versus EVLA with 1470 nm for treatment of incompetent great saphenous vein and short saphenous vein: A randomized controlled trial
    Nasser, Mahmoud M.
    Ghoneim, Baker
    El Daly, Walid
    El Mahdy, Hossam
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2025, 13 (01)
  • [24] Outcome of different endovenous laser wavelengths for great saphenous vein ablation
    Kabnick, LS
    JOURNAL OF VASCULAR SURGERY, 2006, 43 (01) : 88 - 93
  • [25] Regarding "Diffuse phlegmonous phlebitis after endovenous laser treatment of the great saphenous vein" - Reply
    Dunst, Karin M.
    Huemer, Georg M.
    Wayand, Wolfgang
    Shamiyeh, Andreas
    JOURNAL OF VASCULAR SURGERY, 2006, 44 (04) : 913 - 913
  • [26] Treatment of recurrent varicose veins of the great saphenous vein by conventional surgery and endovenous laser ablation
    van Groenendael, Laura
    van der Vliet, J. Adam
    Flinkenflogel, Lizel
    Roovers, Elisabeth A.
    van Sterkenburg, Steven M. M.
    Reijnen, Michel M. P. J.
    JOURNAL OF VASCULAR SURGERY, 2009, 50 (05) : 1106 - 1113
  • [27] Endovenous laser treatment of the great saphenous vein: Measurement of the pullback speed of the fiber by magnetic tracking
    Mordon, S. R.
    Vuylsteke, M. E.
    Mahieu, P.
    Betrouni, N.
    IRBM, 2013, 34 (03) : 252 - 256
  • [28] Venoarterial Flow Index Steadily Improves After Endovenous Laser Treatment of the Great Saphenous Vein
    Rass, Knuth
    Pasquini, Chantal
    Hamsch, Corinna
    Graeber, Stefan
    Frings, Norbert
    Tilgen, Wolfgang
    DERMATOLOGIC SURGERY, 2010, 36 (11) : 1691 - 1699
  • [29] Endovenous Treatment for Great Saphenous Vein Insufficiency: A Comparative Study of Segmental Radiofrequency and 1470-nm Endovenous Laser
    Filippo, Marcio Gomes
    Harduin, Leonardo de Oliveira
    Barroso, Thiago Almeida
    de Almeida, Leonardo Cortizo
    Schanaider, Alberto
    Espinosa, Gaudencio
    VASCULAR AND ENDOVASCULAR SURGERY, 2025,
  • [30] Factors influencing the effectiveness of endovenous laser ablation (EVLA) in the treatment of great saphenous vein reflux
    Theivacumar, N. S.
    Dellagrammaticas, D.
    Beale, R. J.
    Mavor, A. I. D.
    Gough, M. J.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2008, 35 (01) : 119 - 123