Accurate mass determination, quantification and determination of detection limits in liquid chromatography-high-resolution time-of-flight mass spectrometry: Challenges and practical solutions

被引:25
|
作者
Vergeynst, Leendert [1 ]
Van Langenhove, Herman [1 ]
Joos, Pieter [2 ]
Demeestere, Kristof [1 ]
机构
[1] Univ Ghent, Fac Biosci Engn, Dept Sustainable Organ Chem & Technol, Res Grp Environm Organ Chem & Technol, B-9000 Ghent, Belgium
[2] Antweipse Waterwerken Walem, B-2840 Rumst, Belgium
关键词
High-resolution mass spectrometry; Accurate mass; Mass window width; Validation; Micropollutants; Pharmaceuticals; RESIDUE ANALYSIS; WATER SAMPLES; ORGANIC CONTAMINANTS; DRUG RESIDUES; WASTE-WATER; PHARMACEUTICALS; VALIDATION; SUBSTANCES; PESTICIDES; DECISION;
D O I
10.1016/j.aca.2013.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uniform guidelines for the data processing and validation of qualitative and quantitative multi-residue analysis using full-spectrum high-resolution mass spectrometry are scarce. Through systematic research, optimal mass accuracy and sensitivity are obtained after refining the post-processing of the HRMS data. For qualitative analysis, transforming the raw profile spectra to centroid spectra is recommended resulting in a 2.3 fold improved precision on the accurate mass determination of spectrum peaks. However, processing centroid data for quantitative purposes could lead to signal interruption when too narrow mass windows are applied for the construction of extracted ion chromatograms. Therefore, peak integration on the raw profile data is recommended. An optimal width of the mass window of 50 ppm, which is a trade-off between sensitivity and selectivity, was obtained for a TOF instrument providing a resolving power of 20,000 at full width at half maximum (FWHM). For the validation of HRMS analytical methods, widespread concepts such as the signal-to-noise ratios for the determination of decision limits and detection capabilities have shown to be not always applicable because in some cases almost no noise can be detected anymore. A statistical methodology providing a reliable alternative is extended and applied. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 50 条
  • [41] Quantification of codeine by desorption/ionization on silicon time-of-flight mass spectrometry and comparisons with liquid chromatography/mass spectrometry
    Wall, DB
    Finch, JW
    Cohen, SA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (12) : 1403 - 1406
  • [42] Liquid chromatography-high-resolution mass spectrometry for palytoxins in mussels
    Ciminiello, Patrizia
    Dell'Aversano, Carmela
    Dello Iacovo, Emma
    Forino, Martino
    Tartaglione, Luciana
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (05) : 1463 - 1473
  • [43] Determination of selected non-authorized insecticides in peppers by liquid chromatography time-of-flight mass spectrometry and tandem mass spectrometry
    Mezcua, Milagros
    Ferrer, Carmen
    Garcia-Reyes, Juan F.
    Jesus Martinez-Bueno, Maria
    Albarracin, Micaela
    Claret, Maria
    Fernandez-Alba, Amadeo R.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (09) : 1384 - 1392
  • [44] Identification and determination of structurally related peptide impurities in thymalfasin by liquid chromatography-high-resolution mass spectrometry
    Cheng, Yuya
    Wu, Peize
    Kan, Ying
    Li, Ming
    Li, Hongmei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (28) : 8035 - 8045
  • [45] Determination of Celecoxib in human plasma using liquid chromatography with high resolution time of flight-mass spectrometry
    Dongari, Nagaraju
    Sauter, Edward R.
    Tande, Brian M.
    Kubatova, Alena
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 955 : 86 - 92
  • [46] Structurally related peptide impurity identification and accurate quantification for synthetic oxytocin by liquid chromatography-high-resolution mass spectrometry
    Li, Ming
    Josephs, Ralf D.
    Daireaux, Adeline
    Choteau, Tiphaine
    Westwood, Steven
    Martos, Gustavo
    Wielgosz, Robert I.
    Li, Hongmei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (07) : 1861 - 1870
  • [47] Analytical method for determination of dinitropyrenes using gas chromatography-high-resolution mass spectrometry
    Nakao, Teruyuki
    Aozasa, Osamu
    Ohta, Souichi
    Miyata, Hideaki
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) : 352 - 357
  • [48] Dioxins and furans determination in postmortem blood by gas chromatography-high-resolution mass spectrometry
    Cirimele, V
    Villain, A
    Kintz, P
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (02) : 90 - 94
  • [49] Determination of stimulants using gas chromatography/high-resolution time-of-flight mass spectrometry and a soft ionization source
    Lopez-Avila, Viorica
    Cooley, James
    Urdahl, Randall
    Thevis, Mario
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (23) : 2714 - 2724