Magnetic confinement of electron and photon radiotherapy dose: A Monte Carlo simulation with a nonuniform longitudinal magnetic field

被引:27
|
作者
Chen, Y [1 ]
Bielajew, AF
Litzenberg, DW
Moran, JM
Becchetti, FD
机构
[1] Univ Michigan, Dept Phys, Randall Lab, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
electron therapy; dose confinement; magnetic fields; Monte Carlo;
D O I
10.1118/1.2011091
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It recently has been shown experimentally that the focusing provided by a longitudinal nonuniform high magnetic field can significantly improve electron beam dose profiles. This could permit precise targeting of tumors near critical areas and minimize the radiation dose to surrounding healthy tissue. The experimental results together with Monte Carlo simulations suggest that the magnetic confinement of electron radiotherapy beams may provide all alternative to proton or heavy ion radiation therapy in some cases. In the present work, the external magnetic field capability of the Monte Carlo code PENELOPE was utilized by providing a subroutine that modeled the actual field produced by the solenoid magnet used in the experimental studies, The magnetic field in our simulation covered the region from the vacuum exit window to the phantom including surrounding air. In a longitudinal nonuniform magnetic field, it is observed that the electron dose can be focused in both the transverse and longitudinal directions. The measured dose profiles of the electron beam are generally reproduced in the Monte Carlo simulations to within a few percent in the region of interest provided that the geometry and the energy of the incident electron beam are accurately known. Comparisons for the photon beam dose profiles with and without the magnetic field are also made. The experimental results are qualitatively reproduced in the simulation. Our simulation shows that the excessive dose at the beam entrance is due to the magnetic field trapping and focusing scattered secondary electrons that were produced in the air by the incident photon beam. The simulations also show that the electron dose profile can he manipulated by the appropriate control of the beam energy together with the strength and displacement of the longitudinal magnetic field. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3810 / 3818
页数:9
相关论文
共 50 条
  • [41] MONTE CARLO CALCULATION ON THE DOSE MODULATION EFFECT USING DYNAMIC MAGNETIC FIELDS IN PHOTON BEAMS
    Cho, M. J.
    Kim, K. Hwan
    Oh, Y. Kee
    Shin, K. Chul
    Kim, J. Kee
    Jeong, D. Hyeok
    Kim, J. Kee
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S410 - S410
  • [42] Monte Carlo Simulation of Bony Heterogeneity Effects on Dose Profile for Small Irradiation Field in Radiotherapy
    Cardoso, Simone C.
    Alves, Victor Gabriel L.
    da Rosa, Luiz Antonio R.
    Campos, Luciana T.
    Batista, Delano V. S.
    Facure, Alessandro
    PLOS ONE, 2010, 5 (05):
  • [43] SOME ELECTRON TRAJECTORIES IN A NONUNIFORM MAGNETIC FIELD
    CHIN, TN
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1961, 49 (04): : 832 - &
  • [44] Monte Carlo simulation of magnetic properties for nano-magnetic particles
    Du, HF
    Du, A
    Tian, LZ
    Proceedings of the Third International Symposium on Magnetic Industry (ISMI'04) & First International Symposium on Physics and IT Industry (ISITI'04), 2005, : 92 - 94
  • [45] ELECTRON CYCLOTRON HEATING IN A NONUNIFORM MAGNETIC FIELD
    SPROTT, JC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1508 - &
  • [46] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beam radiotherapy
    Hu, A.
    Song, H.
    Chen, Z.
    Zhou, S.
    Yin, F.
    MEDICAL PHYSICS, 2006, 33 (06) : 2099 - 2099
  • [47] Monte Carlo simulations of patient dose perturbations in rotational-type radiotherapy due to a transverse magnetic field: A tomotherapy investigation
    Yang, Y. M.
    Geurts, M.
    Smilowitz, J. B.
    Sterpin, E.
    Bednarz, B. P.
    MEDICAL PHYSICS, 2015, 42 (02) : 715 - 725
  • [48] Monte Carlo simulation of magnetic properties of a mixed spin-2 and spin-5/2 ferrimagnetic Ising system in a longitudinal magnetic field
    Wang, Wei
    Lv, Dan
    Zhang, Fan
    Bi, Jiang-lin
    Chen, Jun-nan
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 385 : 16 - 26
  • [49] Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
    Tzedakis, A
    Damilakis, JE
    Mazonakis, M
    Stratakis, J
    Varveris, H
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2004, 31 (04) : 907 - 913
  • [50] DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations
    Sempau, J
    Wilderman, SJ
    Bielajew, AF
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2263 - 2291