Detection of Ethyl Parathion Using Microcantilever Biosensor

被引:0
|
作者
Xue, Changguo [1 ,2 ]
Nan, Tiegui [3 ]
Wu, Shangquan [2 ]
Cao, Zhen [3 ]
Zhang, Qingchuan [2 ]
Wang, Baomin [3 ]
机构
[1] Anhui Univ Sci & Technol, Sch Mat Sci & Engn, Huainan 232001, Anhui, Peoples R China
[2] Univ Sci & Technol China, Key Lab Mech Behav & Design Mat, Chinese Acad Sci, Hefei 230026, Peoples R China
[3] China Agr Univ, Coll Agron & Biotechnol, Beijing 100094, Peoples R China
关键词
Microcantilever biosensor; Ethyl parathion; Antibody; Self-assembled monolayer;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A microcantilever biosensor has been developed for label-free detection of ethyl parathion. Through self-assembled monolayer (SAM) method, anti ethyl parathion antibody was immobilized on the gold surface of the microcantilever for the measurement of ethyl parathion. The deflection of the microcantilever corresponding to different ethyl parathion concentration was real time monitored by optical lever technique. The experimental results of non-competitive enzyme-linked immunosorbent assay (ELISA) indicate that anti ethyl parathion antibody on the gold surface can keep the activity. Deflection of microcantilever is linear to ethyl parathion concentration from 500-2000 ng/mL. The limit of detection is 500 ng/mL.
引用
收藏
页码:3951 / 3953
页数:3
相关论文
共 50 条
  • [41] Chemodynamics of Methyl Parathion and Ethyl Parathion: Adsorption Models for Sustainable Agriculture
    Tabassum, Noshabah
    Rafique, Uzaira
    Balkhair, Khaled S.
    Ashraf, Muhammad Aqeel
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [42] EXTENT OF MICROENCAPSULATION IN PESTICIDE FORMULATIONS OF DIAZINON, METHYL PARATHION, AND ETHYL PARATHION
    ARGAUER, RJ
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1980, 63 (05): : 1003 - 1006
  • [43] A Self-Sensing Piezoelectric MicroCantilever Biosensor for Detection of Ultrasmall Adsorbed Masses: Theory and Experiments
    Faegh, Samira
    Jalili, Nader
    Sridhar, Srinivas
    SENSORS, 2013, 13 (05) : 6089 - 6108
  • [44] Label-free detection of liver cancer cells by aptamer-based microcantilever biosensor
    Chen, Xuejuan
    Pan, Yangang
    Liu, Huiqing
    Bai, Xiaojing
    Wang, Nan
    Zhang, Bailin
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 353 - 358
  • [45] Thermal decomposition of ethyl and methyl parathion
    Germain, A
    Bizzarri, D
    Dodet, C
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2000, 13 (01) : 1 - 5
  • [46] Simultaneous and Ultrasensitive Detection of Foodborne Bacteria by Gold Nanoparticles-Amplified Microcantilever Array Biosensor
    Zheng, Fengjiao
    Wang, Peixi
    Du, Qingfeng
    Chen, Yiping
    Liu, Nan
    FRONTIERS IN CHEMISTRY, 2019, 7
  • [47] Viral detection using an embedded piezoresistive microcantilever sensor
    Gunter, RL
    Delinger, WG
    Manygoats, K
    Kooser, A
    Porter, TL
    SENSORS AND ACTUATORS A-PHYSICAL, 2003, 107 (03) : 219 - 224
  • [48] NO2 Detection Using Microcantilever Based Potentiometry
    Qazi, Muhammad
    Koley, Goutam
    SENSORS, 2008, 8 (11) : 7144 - 7156
  • [49] Detection of Hg2+ using microcantilever sensors
    Xu, XH
    Thundat, TG
    Brown, GM
    Ji, HF
    ANALYTICAL CHEMISTRY, 2002, 74 (15) : 3611 - 3615
  • [50] Detection of gas trace of hydrofluoric acid using microcantilever
    Mertens, J
    Finot, E
    Nadal, MH
    Eyraud, V
    Heintz, O
    Bourillot, E
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01): : 58 - 65