The wear pattern in metal-on-metal hip prostheses

被引:48
|
作者
Anissian, HL [1 ]
Stark, A
Good, V
Dahlstrand, H
Clarke, IC
机构
[1] Karolinska Hosp, Dept Orthopaed Surg, S-17176 Stockholm, Sweden
[2] Loma Linda Univ, Med Ctr, Dept Orthopaed Surg, Loma Linda, CA 92350 USA
来源
关键词
implants; hip-joint simulator; wear; run-in phase; steady-state phase; metal-on-metal prosthesis;
D O I
10.1002/jbm.1068
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The accumulated data suggest that there is a strong correlation between polyethylene wear and osteolysis, which ultimately leads to prosthetic loosening. Second-generation metal-on-metal prostheses have been introduced, with an eye toward resolving this wear-induced osteolysis problem. The metal particles and ions are biologically active and can affect the cell homeostasis. Thus, defining the wear pattern and ratio of a given metal-on-metal prosthesis system is desirable. An early high-wear or run-in phase followed by a low-wear phase or steady state has been suggested for metal-on-metal hip prostheses. The aim of this study was to define the wear pattern of metal-on-metal bearings. The prosthesis systems were tested in a joint simulator. An early accelerated wear phase transformed to a slower wear phase after 700,000 cycles. The run-in and steady-state wear rates for combined head and liner averaged 2.22 mm(3)/Mc and 1.0 mm(3)/ million cycles, respectively. The metal-on-metal prosthesis featured a biphasic wear trend with the wear ratio in run in being more than twofold higher than the steady-state phase. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:673 / 678
页数:6
相关论文
共 50 条
  • [31] Can metal-on-metal bearings improve the longevity of total hip prostheses?
    Delaunay, C
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (01): : 70 - 78
  • [32] Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses
    Udofia, IJ
    Jin, ZM
    JOURNAL OF BIOMECHANICS, 2003, 36 (04) : 537 - 544
  • [33] Biotribological study of multilayer coated metal-on-metal hip prostheses in a hip joint simulator
    Ortega-Saenz, J. A.
    Alvarez-Vera, M.
    Hernandez-Rodriguez, M. A. L.
    WEAR, 2013, 301 (1-2) : 234 - 242
  • [34] Metal-on-metal hip replacements: Wear performance and cellular response to wear particles
    Campbell, Pat
    McKellop, Harry
    Alim, Rina
    Mirra, Joseph
    Nutt, Steven
    Dorr, L.
    Amstutz, H.C.
    ASTM Special Technical Publication, 1999, (1365): : 193 - 209
  • [35] Wear Simulation of Metal-on-Metal Hip Replacements With Frictional Contact
    Mattei, Lorenza
    Di Puccio, Francesca
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2013, 135 (02):
  • [36] Metal-on-metal hip replacements: Wear performance and cellular response to wear particles
    Campbell, P
    McKellop, H
    Alim, R
    Mirra, J
    Nutt, S
    Dorr, L
    Amstutz, HC
    COBALT-BASE ALLOYS FOR BIOMEDICAL APPLICATIONS, 1999, 1365 : 193 - 209
  • [37] Predictive wear modeling of the articulating metal-on-metal hip replacements
    Gao, Leiming
    Dowson, Duncan
    Hewson, Robert W.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2017, 105 (03) : 497 - 506
  • [38] Comparison of ceramic-on-metal and metal-on-metal hip prostheses under adverse conditions
    Williams, Sophie
    Al-Hajjar, Mazen
    Isaac, Graham H.
    Fisher, John
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (05) : 770 - 775
  • [39] Course of Metal Ions after a Revision of Malfunctioning Metal-on-Metal Total Hip Prostheses
    Nicolli, Annamaria
    Bortoletti, Isabella
    Maso, Stefano
    Trevisan, Andrea
    MEDICINA-LITHUANIA, 2021, 57 (02): : 1 - 6
  • [40] Predictivity and Fate of Metal Ion Release From Metal-On-Metal Total Hip Prostheses
    Nicolli, Annamaria
    Bisinella, Gianluca
    Padovani, Giovanni
    Vitella, Antonio
    Chiara, Federica
    Trevisan, Andrea
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1763 - 1767