Noninvasive Near-Infrared Fluorescence Imaging of the Ureter During Robotic Surgery: A Demonstration in a Porcine Model

被引:7
|
作者
Al-Taher, Mahdi [1 ,2 ]
Okamoto, Nariaki [3 ]
Felli, Eric [1 ]
Agnus, Vincent [1 ]
Barberio, Manuel [1 ]
Gioux, Sylvain [1 ,4 ]
Bouvy, Nicole [2 ]
Stassen, Laurents [2 ]
Marescaux, Jacques [2 ,3 ]
Diana, Michele [1 ,3 ,4 ]
机构
[1] IHU Strasbourg, Inst Image Guided Surg, 1 Pl Hop, F-67091 Strasbourg, France
[2] Maastricht Univ, Dept Surg, Med Ctr, Maastricht, Netherlands
[3] IRCAD, Res Inst Digest Canc, Strasbourg, France
[4] ICUBE Lab, Photon Instrumentat Hlth, Strasbourg, France
关键词
near-infrared fluorescence imaging; ureter; robotic surgery; IRDye800BK; nerindocianine sodium; LAPAROSCOPIC COLORECTAL SURGERY; GYNECOLOGIC SURGERY; INDOCYANINE GREEN; HAPTIC FEEDBACK; RECTAL-CANCER; INJURY; VISUALIZATION; CYSTOSCOPY; PREVENTION;
D O I
10.1089/lap.2020.0399
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background:Iatrogenic ureteral injury is one of the feared complications during intrapelvic surgery. There are limited data on the use of novel near-infrared fluorescence (NIRF) imaging dyes for the purpose of noninvasive ureteral visualization in robot-assisted laparoscopic surgery (RALS). In this study, we evaluated the feasibility of NIRF imaging of the ureter using the IRDye(R)800BK dye as the fluorescence dye and a robotic platform with Firefly (TM) technology as an imaging system. Materials and Methods:An intravenous dose of 0.15 mg/kg was administered in 3 pigs and NIRF imaging was performed for a total duration of 60 minutes. The intraoperative video recordings were analyzed to determine fluorescence intensities and the target-to-background ratio (TBR). Results:In all included animals, a clear delineation of the ureter was achieved from 5 minutes after dye administration until the end of the study. During this time period, the ureter was clearly distinguishable from its surroundings and no statistical differences in TBR were observed. Conclusion:The IRDye 800BK dye, a novel NIRF dye currently undergoing clinical translation, is a promising contrast agent used for noninvasive ureteral imaging, which has the potential to be valuable during RALS.
引用
收藏
页码:962 / 966
页数:5
相关论文
共 50 条
  • [31] Application of Near-Infrared Fluorescence Imaging Technology in Liver Cancer Surgery
    Liu, Ying
    Gao, Benjian
    Fang, Cheng
    Su, Song
    Yang, Xiaoli
    Tian, Jie
    Li, Bo
    SURGICAL INNOVATION, 2022, 29 (04) : 532 - 539
  • [32] Current Applications of Near-infrared Fluorescence Imaging in Robotic Urologic Surgery: A Systematic Review and Critical Analysis of the Literature
    Autorino, Riccardo
    Zargar, Homayoun
    White, Wesley M.
    Novara, Giacomo
    Annino, Filippo
    Perdona, Sisto
    De Angelis, Michele
    Mottrie, Alexandre
    Porpiglia, Francesco
    Kaouk, Jihad H.
    UROLOGY, 2014, 84 (04) : 751 - 759
  • [33] INTEGRATED ROBOTIC NEAR-INFRARED FLUORESCENCE DURING ROBOTIC PARTIAL NEPHRECTOMY: CORRELATION WITH TUMOR HISTOLOGY
    Abaza, Ronney
    JOURNAL OF ENDOUROLOGY, 2012, 26 : A155 - A155
  • [34] INTEGRATED ROBOTIC NEAR-INFRARED FLUORESCENCE DURING ROBOTIC PARTIAL NEPHRECTOMY: CORRELATION WITH TUMOR HISTOLOGY
    Abaza, Ronney
    JOURNAL OF UROLOGY, 2012, 187 (04): : E565 - E565
  • [35] The Utility of Near-Infrared Fluorescence and Indocyanine Green During Robotic Pulmonary Resection
    Ferrari-Light, Dana
    Geraci, Travis C.
    Sasankan, Prabhu
    Cerfolio, Robert J.
    FRONTIERS IN SURGERY, 2019, 6
  • [36] Intra-operative visualization of the ureter by near-infrared fluorescence during robotic-assisted laparoscopic sigmoidectomy for diverticulitis - a video vignette
    Khan, F.
    Keenan, R.
    Keyes, A.
    Cahill, R. A.
    COLORECTAL DISEASE, 2020, 22 (03) : 354 - 355
  • [37] Intraoperative ureter visualization using a near-infrared imaging agent
    Farnam, Richard W.
    Arms, Richard G., III
    Klaassen, Alwin H.
    Sorger, Jonathan M.
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (06)
  • [38] (Near-infrared) fluorescence guidance during surgery: What is the detection limit?
    KleinJan, G. H.
    Bunschoten, A.
    Engelen, T.
    van den Berg, N. S.
    Olmos, R. A. Valdes
    Wester, H.
    van Leeuwen, F. W. B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S433 - S434
  • [39] Near-Infrared Fluorescence Imaging with Intraoperative Administration of Indocyanine Green for Robotic Partial Nephrectomy
    Marc A. Bjurlin
    Tyler R. McClintock
    Michael D. Stifelman
    Current Urology Reports, 2015, 16
  • [40] Near-Infrared Fluorescence Imaging with Intraoperative Administration of Indocyanine Green for Robotic Partial Nephrectomy
    Bjurlin, Marc A.
    McClintock, Tyler R.
    Stifelman, Michael D.
    CURRENT UROLOGY REPORTS, 2015, 16 (04)