Late clinical outcomes after implantation of drug-eluting stents coated with biodegradable polymers: 3-year follow-up of the PAINT randomised trial

被引:14
|
作者
Lemos, Pedro A. [1 ]
Moulin, Bruno [2 ]
Perin, Marco A. [3 ]
Oliveira, Ludmilla A. R. R. [4 ]
Airton Arruda, J. [5 ]
Lima, Valter C. [6 ]
Lima, Antonio A. G. [7 ]
Caramori, Paulo R. A. [8 ]
Medeiros, Cesar R. [9 ]
Barbosa, Mauricio R. [10 ]
Brito, Fabio S., Jr. [11 ]
Ribeiro, Expedito E. [1 ]
机构
[1] Univ Sao Paulo, Med Sch USP, Heart Inst InCor, Sao Paulo, Brazil
[2] Hosp Univ Cassiano Antonio de Moraes, Vitoria, Brazil
[3] Hosp Santa Marcelina, Sao Paulo, Brazil
[4] Natal Hosp Ctr, Natal, RN, Brazil
[5] Hosp Merid, Vitoria, Brazil
[6] Univ Fed Sao Paulo UNIFESP EPM, Sao Paulo, Brazil
[7] Hosp Univ Walter Cantidio, Fortaleza, Ceara, Brazil
[8] PUC RS, Hosp Sao Lucas, Porto Alegre, RS, Brazil
[9] Rede DOr Hosp, Rio De Janeiro, Brazil
[10] Hosp Biocor, Belo Horizonte, MG, Brazil
[11] Sao Camilo Hosp, Sao Paulo, Brazil
关键词
restenosis; randomised clinical trial; drug-eluting stents; coronary; angioplasty; atherosclerosis; biodegradable;
D O I
10.4244/EIJV8I1A18
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The long-term clinical performance of drug-eluting stents (DES) coated with biodegradable polymers is poorly known. Methods and results: A total of 274 coronary patients were randomly allocated to paclitaxel-eluting stents, sirolimus-eluting stents, or bare metal stems (2:2:1 ratio). The two DES used the same biodegradable polymers and were identical except for the drug. At three years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9.0% vs. 7.1; p=0.6), but lower risk of repeat interventions (10.0% vs. 29.9%; p<0.01) than controls with bare stents. The cumulative 3-year incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (first year: 1.8%; second year: 0.4%; third year: zero). There were no significant differences in outcomes between paclitaxel- and sirolimus-eluting stents. Conclusions: The biodegradable-polymer coated DES releasing either paclitaxel or sirolimus were effective in reducing the 3-year rate of re-interventions.
引用
收藏
页码:117 / 119
页数:3
相关论文
共 50 条
  • [21] Biodegradable Polymer Versus Permanent Polymer Drug-Eluting Stents and Everolimus- Versus Sirolimus-Eluting Stents in Patients With Coronary Artery Disease 3-Year Outcomes From a Randomized Clinical Trial
    Byrne, Robert A.
    Kastrati, Adnan
    Massberg, Steffen
    Wieczorek, Anna
    Laugwitz, Karl-Ludwig
    Hadamitzky, Martin
    Schulz, Stefanie
    Pache, Juergen
    Fusaro, Massimiliano
    Hausleiter, Joerg
    Schoemig, Albert
    Mehilli, Julinda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (13) : 1325 - 1331
  • [22] Impact of late drug-eluting stent malapposition on 3-year clinical events
    Hong, Myeong-Ki
    Mintz, Gary S.
    Lee, Cheol Whan
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Kang, Duk-Hyun
    Cheong, Sang-Sig
    Song, Jae-Kwan
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (15) : 1515 - 1516
  • [23] PREVALENCE OF NEOATHEROSCLEROSIS IN VERY LATE FOLLOW-UP OF SECOND-GENERATION DRUG-ELUTING STENTS
    Chen, Zhaoyang
    Matsumura, Mitsuaki
    Mintz, Gary
    Noguchi, Masahiko
    Zhang, Mingyou
    Song, Lei
    Yin, Dong
    Ali, Ziad
    Porter, Craig
    Haag, Elizabeth
    Cao, Jane
    Jeremias, Allen
    Shlofmitz, Richard
    Maehara, Akiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1419 - 1419
  • [24] Clinical outcomes of drug coated balloon in coronary lesions: 3-year follow-up of CAGE FREE Registry
    Wang, R.
    Yang, W.
    Liu, J.
    Mou, F.
    Liu, Y.
    Zhou, J.
    Yin, Z.
    Wang, Q.
    Yuan, M.
    Li, F.
    Li, C.
    Gao, C.
    Tao, L.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [25] Long-term efficacy and safety of drug-coated balloons versus drug-eluting stents for small coronary artery disease (BASKET-SMALL 2): 3-year follow-up of a randomised, non-inferiority trial
    Jeger, Raban V.
    Farah, Ahmed
    Ohlow, Marc-Alexander
    Mangner, Norman
    Mobius-Winkler, Sven
    Weilenmann, Daniel
    Woehrle, Jochen
    Stachel, Georg
    Markovic, Sinisa
    Leibundgut, Gregor
    Rickenbacher, Peter
    Osswald, Stefan
    Cattaneo, Marco
    Gilgen, Nicole
    Kaiser, Christoph
    Scheller, Bruno
    LANCET, 2020, 396 (10261): : 1504 - 1510
  • [26] Biodegradable or durable polymer drug-eluting stents in patients with coronary artery disease: ten-year outcomes of the randomised NEXT Trial
    Natsuaki, Masahiro
    Watanabe, Hirotoshi
    Morimoto, Takeshi
    Kozuma, Ken
    Kadota, Kazushige
    Muramatsu, Toshiya
    Nakagawa, Yoshihisa
    Akasaka, Takashi
    Hanaoka, Keiichi Igarashi
    Tanabe, Kengo
    Morino, Yoshihiro
    Ishikawa, Tetsuya
    Katoh, Harumi
    Nishikawa, Hideo
    Tamura, Toshihiro
    Ono, Koh
    Yamamoto, Ko
    Ishihara, Takayuki
    Abe, Mitsuru
    Taniguchi, Ryoji
    Ikari, Yuji
    Okada, Kozo
    Kimura, Takeshi
    EUROINTERVENTION, 2023, 19 (05) : E402 - E413
  • [27] Routine Follow Up Coronary Angiography versus Clinical Follow Up Only in Patients With Dyslipidemia Following Percutaneous Coronary Intervention With Drug-eluting Stents: 3-year Clinical Follow Up Results
    Rha, Seung Woon
    Choi, Byoung Geol
    Choi, Se Yeon
    Byun, Jae Kyeong
    Na, Jin Oh
    Choi, Cheol Ung
    Lim, Hong Euy
    Kim, Jin Won
    Kim, Eung Ju
    Park, Chang Gyu
    Seo, Hong Seog
    Oh, Dong Joo
    CIRCULATION, 2015, 132
  • [28] Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up
    Pellegrini, Denise Oliveira
    Gomes, Vitor Osorio
    Lasevitch, Ricardo
    Smidt, Luis
    Azeredo, Marco Aurelio
    Ledur, Priscila
    Bodanese, Rodrigo
    Sinnott, Leonardo
    Moriguchi, Emlio
    Caramori, Paulo
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2014, 103 (03) : 174 - 181
  • [29] TEN-YEAR FOLLOW-UP OF THE DESIRE (DRUG-ELUTING STENTS IN THE REAL WORLD) REGISTRY
    Costa, Jose de Ribamar
    Sousa, Amanda
    Moreira, Adriana
    Costa, Ricado
    Cano, Manuel
    Maldonado, Galo
    Campos, Cantidio
    Neto
    Egito, Enilto
    Pavanelo, Ricardo
    Sousa, J. Eduardo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1736 - E1736
  • [30] Insufficient recovery of fractional flow reserve even after optimal implantation of drug-eluting stents: 3-year outcomes from the FUJI study
    Hokama, Yohei
    Tanaka, Nobuhiro
    Takashima, Hiroaki
    Kadota, Kazushige
    Fujita, Hiroshi
    Tan, Michinao
    Yamada, Ryotaro
    Naruse, Hiroyuki
    Kawamura, Akio
    Suzuki, Nobuaki
    Takeuchi, Tsuyoshi
    Tazaki, Junichi
    Yamaki, Masaru
    Takamisawa, Itaru
    Abe, Shichiro
    Terai, Hidenobu
    Makiguchi, Noriko
    Matsumoto, Chisa
    Chikamori, Taishiro
    JOURNAL OF CARDIOLOGY, 2021, 77 (05) : 532 - 538