Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography

被引:34
|
作者
Bernhardt, TM
Otto, D
Reichel, G
Ludwig, K
Seifert, S
Kropf, S
Rapp-Bernhardt, U
机构
[1] Otto von Guericke Univ, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
[2] Otto von Guericke Univ, Dept Biometr & Med Informat, D-39120 Magdeburg, Germany
关键词
lung; radiography; phantoms; comparative studies; digital; selenium detector; storage phosphor; receiver operating characteristic (ROC) curve;
D O I
10.1148/radiology.213.2.r99nv20445
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the diagnostic performance of storage phosphor and digital selenium radiography (DSR) with asymmetric and symmetric screen-film systems at different, speeds in the detection of simulated interstitial lung disease and catheters. MATERIALS AND METHODS: Patterns of simulated interstitial lung disease and catheters were superimposed over an anthropomorphic chest phantom. Hard-copy images were generated at DSR (200-, 400-, and 600-speed), storage phosphor radiography (200- and 400-speed), and asymmetric (400-speed) and symmetric (200- and 400-speed) screen-film imaging. Surface doses were measured, and receiver operating characteristic analyses were performed. RESULTS: No statistically significant differences were found between the detector systems with the same speeds for each interstitial pattern. Significantly poorer results were found at 600-speed DSR than at 200-speed DSR. Detection of catheters and nodules over high-attenuation areas was significantly worse with the symmetric screen-film system than with the other detectors. The surface dose with the DSR system, without a grid, was about 50% less than that of the other detector systems, with grids, tit the same speed. CONCLUSION: No significant difference was found in the diagnostic performance at DSR, storage phosphor radiography, and film-based radiography for simulated interstitial lung disease at corresponding speeds; there was a reduction in the surface dose of about 50% with the 400-speed DSR system.
引用
收藏
页码:445 / 454
页数:10
相关论文
共 48 条
  • [21] Lung nodule conspicuity using unsharp mask filters with storage-phosphor-based computed radiography
    Li, F
    Sone, S
    Kiyono, K
    ACTA RADIOLOGICA, 1997, 38 (01) : 99 - 103
  • [22] Digital slot-scan charge-coupled device radiography versus AMBER and bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom
    Kroft, LJM
    Geleijns, J
    Mertens, BJA
    Veldkamp, WJH
    Zonderland, HM
    de Roos, A
    RADIOLOGY, 2004, 231 (01) : 156 - 163
  • [23] Accuracy of Digital Tomosynthesis of the Chest in Detection of Interstitial Lung Disease Comparison With Digital Chest Radiography
    Kruamak, Temphon
    Edwards, Rachael
    Cheng, Stephanie
    Hippe, Daniel S.
    Raghu, Ganesh
    Pipavath, Sudhakar N. J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (01) : 109 - 114
  • [24] A ROC Study of AMBER and conventional chest imaging in the detection of simulated interstitial lung disease
    vanSchelven, IH
    Winter, LHL
    Chakraborty, DP
    Kool, LJS
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 67 - 71
  • [25] INTERSTITIAL PULMONARY-DISEASE - A COMPARISON BETWEEN FILM-SCREEN TECHNIQUE AND DIGITAL STORAGE PHOSPHOR TECHNIQUE
    DOLKEN, W
    CHOWANETZ, W
    HORWITZ, AE
    KRAHE, T
    LANDWEHR, P
    LACKNER, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (01): : 61 - 67
  • [26] DETECTION OF SUBTLE INTERSTITIAL LUNG-DISEASES - COMPARISON OF CONVENTIONAL AND HIGH-RESOLUTION STORAGE PHOSPHOR IMAGING
    SONG, K
    LEE, J
    LIM, T
    RADIOLOGY, 1995, 197 : 340 - 340
  • [27] Performance of a new digital flat panel detector in the detection of artificial bone lesions: A comparison with conventional screen-film radiography and phosphor-storage radiography
    Ludwig, K
    Lenzen, H
    Kamm, K
    Link, TM
    Diederich, S
    Wormanns, D
    RADIOLOGY, 2000, 217 : 517 - 517
  • [28] Utility of a Deep Learning Algorithm for Detection of Reticular Opacity on Chest Radiography in Patients With Interstitial Lung Disease
    Kim, Wooil
    Lee, Sang Min
    Kim, Jung Im
    Ahn, Yura
    Park, Sohee
    Choe, Jooae
    Seo, Joon Beom
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (04) : 642 - 650
  • [29] DIGITAL CHEST IMAGING USING A SELENIUM DETECTOR - A SIMULATED DIFFUSE INTERSTITIAL PULMONARY-DISEASE DETECTION STUDY
    VANHEESEWIJK, HPM
    VANDERGRAAF, Y
    DEVALOIS, JC
    FELDBERG, MAM
    INVESTIGATIVE RADIOLOGY, 1995, 30 (05) : 300 - 305
  • [30] A comparison of high resolution storage phosphor radiographs (4K) and selenium radiographs (2K) in the detection of simulated chest lesions
    SchaeferProkop, CM
    Prokop, M
    Bolooreki, K
    Schmidt, A
    Kausche, H
    Siemund, R
    RADIOLOGY, 1997, 205 : 1252 - 1252