Experimental analysis and FLUENT simulation of a stratified chilled water storage system

被引:5
|
作者
Tang, J. L. [1 ,2 ]
OuYang, Z. R. [1 ]
Shi, Y. Y. [1 ]
机构
[1] Chinese Acad Sci, High Magnet Field Lab, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2019年 / 134卷 / 03期
关键词
D O I
10.1140/epjp/i2019-12579-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
.The purpose of this study is to figure out the hydrodynamic disturbance characteristics and chilled water storage efficiency improvement technique of a storage tank by a series of experimental analysis and FLUENT simulation. A new type of diffusion nozzle was designed, which stemmed from the Coanda effect, and an optimization is done by the numerical simulation method. Comparison analysis by FLUENT simulation on different diffusion angles of the nozzle was made, and the hydrodynamic disturbance was minimal when the diffusion surface was flat and the outlet edge of the nozzle was radial. The diffuser performance testing platform was designed and installed for comparative experimental analysis of various types of diffuser. Three groups of experiments are carried out under the original octagonal diffuser, the octagonal diffuser with nozzles and the octagonal diffuser with nozzles and uniform flow orifice. The chilled water storage efficiency could reach up to 90% when the third scheme was selected.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] EXPERIMENTAL INVESTIGATION OF CHILLED WATER STORAGE TECHNIQUE FOR PEAK POWER SHAVING
    SURI, RK
    ALMARAFIE, AMR
    MAHESHWARI, GP
    ALJUWAYHEL, F
    ALJANDAL, S
    ALMADANI, K
    ABURSHAID, H
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1989, 12 (04): : 213 - 219
  • [22] Measured and modeled charging of a stratified chilled water thermal storage tank with slotted pipe diffusers
    Bahnfleth, WP
    Song, J
    Cimbala, JM
    HVAC&R RESEARCH, 2003, 9 (04): : 467 - 491
  • [23] CHILLED WATER STORAGE-SYSTEM REDUCES ENERGY COSTS
    FIORINO, DP
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (04): : 30 - 33
  • [24] Thermoeconomic evaluation of air conditioning system with chilled water storage
    Lin, Hu
    Li, Xin-hong
    Cheng, Peng-sheng
    Xu, Bu-gong
    ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 328 - 332
  • [25] Performance assessment of stratified chilled water thermal energy storage tank at district cooling plant
    Majid, M. A. A.
    Hui, P. S.
    Soomro, A. A.
    SYMPOSIUM ON ENERGY SYSTEMS 2019 (SES 2019), 2020, 863
  • [26] Energy analysis of chilled water system configurations using simulation-based optimization
    Ali, Muzaffar
    Vukovic, Vladimir
    Sahir, Mukhtar Hussain
    Fontanella, Giuliano
    ENERGY AND BUILDINGS, 2013, 59 : 111 - 122
  • [27] Transient analysis of thermal stratification in chilled water storage tanks
    Gopalakrishnan, N.
    Srinivasa Murthy, S.
    International Journal of Heat and Technology, 2010, 28 (01) : 45 - 52
  • [28] Modeling and Simulation of Chilled Water System for Central Air Conditioning
    Sun, Jianmin
    Zhang, Chundong
    Zhou, Zeyang
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4280 - 4285
  • [29] THEORETICAL AND EXPERIMENTAL STUDIES OF STRATIFIED THERMOCLINE STORAGE OF HOT WATER
    ABDOLY, MA
    RAPP, D
    ENERGY CONVERSION AND MANAGEMENT, 1982, 22 (03) : 275 - 285
  • [30] ANALYSIS OF A CHILLED JET IN A THERMALLY STRATIFIED ENVIRONMENT
    BALL, HD
    BAILEY, TF
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (12): : 52 - 52