Experimental analysis and FLUENT simulation of a stratified chilled water storage system

被引:5
|
作者
Tang, J. L. [1 ,2 ]
OuYang, Z. R. [1 ]
Shi, Y. Y. [1 ]
机构
[1] Chinese Acad Sci, High Magnet Field Lab, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2019年 / 134卷 / 03期
关键词
D O I
10.1140/epjp/i2019-12579-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
.The purpose of this study is to figure out the hydrodynamic disturbance characteristics and chilled water storage efficiency improvement technique of a storage tank by a series of experimental analysis and FLUENT simulation. A new type of diffusion nozzle was designed, which stemmed from the Coanda effect, and an optimization is done by the numerical simulation method. Comparison analysis by FLUENT simulation on different diffusion angles of the nozzle was made, and the hydrodynamic disturbance was minimal when the diffusion surface was flat and the outlet edge of the nozzle was radial. The diffuser performance testing platform was designed and installed for comparative experimental analysis of various types of diffuser. Three groups of experiments are carried out under the original octagonal diffuser, the octagonal diffuser with nozzles and the octagonal diffuser with nozzles and uniform flow orifice. The chilled water storage efficiency could reach up to 90% when the third scheme was selected.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Experimental analysis and FLUENT simulation of a stratified chilled water storage system
    J. L. Tang
    Z. R. OuYang
    Y. Y. Shi
    The European Physical Journal Plus, 134
  • [2] Experimental investigation of a stratified chilled-water thermal storage system
    Karim, M. A.
    APPLIED THERMAL ENGINEERING, 2011, 31 (11-12) : 1853 - 1860
  • [3] Tank size and operating strategy optimization of a stratified chilled water storage system
    Zhang, Zhiqin
    Turner, William D.
    Chen, Qiang
    Xu, Chen
    Deng, Song
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2656 - 2664
  • [4] STRATIFIED STORAGE ECONOMICALLY INCREASES CAPACITY AND EFFICIENCY OF CAMPUS CHILLED WATER-SYSTEM
    BAHNFLETH, WP
    JOYCE, WS
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1995, 37 (03): : 46 - 49
  • [5] Performance study on short stratified chilled water storage tank
    Ke, MT
    Cheng, TC
    Hsiao, KY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 161 - 168
  • [6] Parametric studies on thermally stratified chilled water storage systems
    Nelson, JEB
    Balakrishnan, AR
    Murthy, SS
    APPLIED THERMAL ENGINEERING, 1999, 19 (01) : 89 - 115
  • [7] Heat Transfer Analysis of Stratified Chilled Water Storage Tank for District Cooling Systems
    Bhatkar, Vijay W.
    Shastri, Dhiresh S.
    Kaithari, Dinesh K.
    Bhambare, Parimal S.
    Allampallewar, Girish L.
    Meherkar, Amar A.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2025, 43 (01) : 39 - 46
  • [8] The chilled water storage analysis for a university building cooling system
    Boonnasa, Somkiat
    Namprakai, Pichai
    APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) : 1396 - 1408
  • [9] Laminar flow efficiency of stratified chilled-water storage tanks
    Homan, KO
    Soo, SL
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1998, 19 (01) : 69 - 78
  • [10] Model of the transient stratified flow into a chilled-water storage tank
    Homan, KO
    Soo, SL
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (18) : 4367 - 4377