Simulation of Actively Polarimetric Calibration Source Based on Correlated Noise Signals by Simulink

被引:0
|
作者
Li, Jiaoyang [1 ,2 ]
Wang, Zhenzhan [2 ]
机构
[1] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Natl Space Sci Ctr, Key Lab Microwave Remote Sensing, Beijing 100190, Peoples R China
关键词
MICROWAVE RADIOMETERS; STANDARD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fully polarimetric microwave radiometer can receive both the two orthogonal polarization components and their complex correlation components, which are defined as the third and fourth Stokes parameters, of the signals radiated from the detected target. In order to achieve the precisely quantitative remote sensing of fully polarimetric radiometer, an accurate calibration is necessary. For this purpose, a uniformly stable and accurate calibration source which is performed as the calibration standard is of vital importance. The traditional and commonly used blackbody calibration target can't radiate signals with polarized components. So it is significant to design an active calibration source to generate noise signals with full polarized components for fully polarimetric microwave radiometer calibration. With the full investigation into the pre-existing polarimetric calibration sources and their characteristics, this paper design a miniature and portable actively polarmetric calibration source. First of all, the design principles of the calibration source of fully polarized microwave radiometer based on correlated noise signals are elaborated. Secondly, MATLAB/Simulink is used to establish the simulation model of the calibration source. The reference signals generation module generates the original reference signals with full polarized components which can be controlled by program language. The original reference signals are converted to the signals with the designed frequency by the frequency modulation module. The noise voltage control module outputs the noise signals with different voltages which covered all the counts needed for polarimetric radiometer calibration within the voltage counts of cold and hot target. Finally, the power spectrum of each module of the simulation model is given. The results show a great consistency between the theoretical and simulated results. Thus, the feasibility of the designed calibration source for fully polarimetric microwave radiometer based on the program language controlled correlated noise signals is verified. Therefore, the functional block diagram of the real circuits of this calibration source based on the simulation is designed for the practical application.
引用
收藏
页码:2344 / 2349
页数:6
相关论文
共 38 条
  • [31] A fast correlated multiple sampling technique based on 12-bit SAR ADC with digital calibration for low-noise CMOS image sensor
    Nie, Kaiming
    Yin, Zhaoyang
    Xu, Jiangtao
    MICROELECTRONICS JOURNAL, 2017, 59 : 47 - 54
  • [32] Millimeter-Wave SiGe Radiometer Front End With Transformer-Based Dicke Switch and On-Chip Calibration Noise Source
    Frounchi, Milad
    Alizadeh, Amirreza
    Ying, Hanbin
    Coen, Christopher T.
    Gasiewski, Albin J.
    Cressler, John D.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2021, 56 (05) : 1464 - 1474
  • [33] Identification of jet noise source using causality method based on large-eddy simulation of a round jet flow
    Lee, Hyunsun
    Uzun, Ali
    Hussaini, M. Yousuff
    INTERNATIONAL JOURNAL OF AEROACOUSTICS, 2017, 16 (1-2) : 78 - 96
  • [34] Development of aircraft noise simulation framework J-FRAIN based on component-wise sound source models
    Takaishi, Takehisa
    Kobayashi, Tomohiro
    Ikuta, Yuho
    Imamura, Taro
    Kawase, Yasuaki
    NOISE CONTROL ENGINEERING JOURNAL, 2024, 72 (04) : 278 - 296
  • [35] A Pass-By Noise Prediction Method Based on Source-Path-Receiver Approach Combining Simulation and Test Data
    Calloni, Massimiliano
    Musser, Chadwyck
    Castel, Alexis
    Mejdi, Abderrazak
    Medeiros, Augusto
    SAE International Journal of Advances and Current Practices in Mobility, 2019, 1 (01): : 120 - 125
  • [36] EEGSourceSim: A framework for realistic simulation of EEG scalp data using MRI-based forward models and biologically plausible signals and noise
    Barzegaran, Elham
    Bosse, Sebastian
    Kohler, Peter J.
    Norcia, Anthony M.
    JOURNAL OF NEUROSCIENCE METHODS, 2019, 328
  • [37] Simulation study on highly-enriched uranium components with reflector based on 252Cf source-driven noise analysis method
    Zhou, Mi
    Wei, Biao
    Mi, Deling
    Yang, Fan
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (05):
  • [38] Simulation effect evaluation of single-outlet and multi-outlet calibration of Soil and Water Assessment Tool model driven by Climate Forecast System Reanalysis data and ground-based meteorological station data - a case study in a Yellow River source
    Li, Kai
    Wang, Yongqiang
    Li, Xiaodong
    Yuan, Zhe
    Xu, Jijun
    WATER SUPPLY, 2021, 21 (03) : 1061 - 1071