Simulation of Actively Polarimetric Calibration Source Based on Correlated Noise Signals by Simulink

被引:0
|
作者
Li, Jiaoyang [1 ,2 ]
Wang, Zhenzhan [2 ]
机构
[1] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[2] Chinese Acad Sci, Natl Space Sci Ctr, Key Lab Microwave Remote Sensing, Beijing 100190, Peoples R China
关键词
MICROWAVE RADIOMETERS; STANDARD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fully polarimetric microwave radiometer can receive both the two orthogonal polarization components and their complex correlation components, which are defined as the third and fourth Stokes parameters, of the signals radiated from the detected target. In order to achieve the precisely quantitative remote sensing of fully polarimetric radiometer, an accurate calibration is necessary. For this purpose, a uniformly stable and accurate calibration source which is performed as the calibration standard is of vital importance. The traditional and commonly used blackbody calibration target can't radiate signals with polarized components. So it is significant to design an active calibration source to generate noise signals with full polarized components for fully polarimetric microwave radiometer calibration. With the full investigation into the pre-existing polarimetric calibration sources and their characteristics, this paper design a miniature and portable actively polarmetric calibration source. First of all, the design principles of the calibration source of fully polarized microwave radiometer based on correlated noise signals are elaborated. Secondly, MATLAB/Simulink is used to establish the simulation model of the calibration source. The reference signals generation module generates the original reference signals with full polarized components which can be controlled by program language. The original reference signals are converted to the signals with the designed frequency by the frequency modulation module. The noise voltage control module outputs the noise signals with different voltages which covered all the counts needed for polarimetric radiometer calibration within the voltage counts of cold and hot target. Finally, the power spectrum of each module of the simulation model is given. The results show a great consistency between the theoretical and simulated results. Thus, the feasibility of the designed calibration source for fully polarimetric microwave radiometer based on the program language controlled correlated noise signals is verified. Therefore, the functional block diagram of the real circuits of this calibration source based on the simulation is designed for the practical application.
引用
收藏
页码:2344 / 2349
页数:6
相关论文
共 38 条
  • [1] A correlated noise calibration source for the internal calibration of a fully polarimetric radiometer
    Oh, Myeonggeun
    Kim, Yong-Hoon
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2019, 61 (01) : 73 - 76
  • [2] Calibration Method for Fully Polarimetric Microwave Radiometers Using the Correlated Noise Calibration Standard
    Peng, Jinzheng
    Ruf, Christopher S.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2008, 46 (10): : 3087 - 3097
  • [3] A correlated noise calibration standard for interferometric, polarimetric, and autocorrelation microwave radiometers
    Ruf, CS
    Li, JK
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (10): : 2187 - 2196
  • [4] Separation of Colored Noise from Vibration Signals: A Simulation Using Simulink
    Zhang, JiaFan
    Xin, HongLi
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON MODELLING AND SIMULATION (ICMS2009), VOL 7, 2009, : 118 - 123
  • [5] Calibration of a Fully Polarimetric Microwave Radiometer Using a Digital Polarimeric Noise Source
    Lim, Boon H.
    Ruf, Christopher S.
    2006 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, 2006, : 3992 - 3995
  • [6] The Identification of Engine Noise Source Based on Simulink Blind Sources Separation
    Gao, Junwen
    Quan, Yanming
    Li, Yongman
    MECHATRONICS AND MATERIALS PROCESSING I, PTS 1-3, 2011, 328-330 : 2134 - +
  • [7] Rotating Machine Monitoring Based on Blind Source Separation of Correlated Source Signals
    Li, Ning
    Chen, Haiting
    Liu, Shaopeng
    MECHATRONICS AND INDUSTRIAL INFORMATICS, PTS 1-4, 2013, 321-324 : 1299 - 1302
  • [8] Correlated EEG Signals Simulation Based on Artificial Neural Networks
    Tomasevic, Nikola M.
    Neskovic, Aleksandar M.
    Neskovic, Natasa J.
    INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2017, 27 (05)
  • [9] Localization of coherent signals without source number knowledge in unknown spatially correlated Gaussian noise
    Qian, Cheng
    Huang, Lei
    Xiao, Yuhang
    So, H. C.
    SIGNAL PROCESSING, 2015, 111 : 170 - 178
  • [10] Recursive estimation algorithm based on covariances for uncertainly observed signals correlated with noise
    Nakamori, Seiichi
    Caballero-Aguila, Raquel
    Hermoso-Carazo, Aurora
    Jimenez-Lopez, Jose D.
    Linares-Perez, Josefa
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2008, E91A (07) : 1706 - 1712