The aneurysmal arteriovenous fistula - morphological study and assessment of clinical implications. A pilot study

被引:6
|
作者
Watson, Kenneth R. [1 ]
Gallagher, Maeve [1 ]
Ross, Rose [2 ]
Severn, Alison [3 ]
Nagy, Janos [2 ]
Cochrane, Lynda [4 ]
Griffiths, Gareth D. [2 ]
机构
[1] Univ Dundee, Sch Med, Dundee DD1 4HN, Scotland
[2] Ninewells Hosp & Med Sch, Dept Vasc Surg, Dundee, Scotland
[3] Ninewells Hosp & Med Sch, Dept Nephrol, Dundee, Scotland
[4] Univ Dundee, Dundee Epidemiol & Biostat Unit, Dundee DD1 4HN, Scotland
关键词
Aneurysm; surgical arteriovenous shunt; renal dialysis; colour doppler; ultrasonography; DOPPLER ULTRASOUND ASSESSMENT; HEMODIALYSIS; ACCESS; COMPLICATIONS; DISEASE;
D O I
10.1177/1708538114557069
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aneurysmal dilation of arteriovenous fistulae used for haemodialysis is a recognised complication but its clinical significance is a contentious issue. Our aims were to describe aneurysmal fistulae morphologically and clinically. Sixty patients underwent duplex scanning to measure the maximum diameter and skin thickness of their fistula. Haemodialysis function and bleeding risk were assessed clinically. The 75th percentile of maximum diameter was 2.05 cm. In addition to conventional diameter measurement, we describe a novel volume measurement technique which may be of value. No relationship was found between maximum diameter or volume and function, skin thickness or bleeding. Some studies define aneurysm at 2 cm (75th percentile); however, this definition and other arbitrary definitions lack clinical significance. This work suggests that fistula dilation should be considered together with clinical issues when determining the clinical significance of an aneurysm. Our finding that haemodialysis function, skin thickness and bleeding were not associated with diameter needs further study.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [1] TRIBOELECTRIC EVALUATION OF ARTERIOVENOUS FISTULA FOR HAEMODIALYSIS: A PILOT STUDY
    Presta, Pierangela
    Oliva, Giuseppe
    Musolino, Michela
    Fabiano, Giuseppe
    Carullo, Nazareno
    Armeni, Annarita
    Chiarella, Salvatore
    Andreucci, Michele
    Fiorillo, Antonio
    Bolignano, Davide
    Pullano, Salvatore
    Coppolino, Giuseppe
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I728 - I729
  • [2] Dural arteriovenous fistula masquerading as pulsatile tinnitus: radiologic assessment and clinical implications
    Yong-Hwi An
    Sungjun Han
    Minhyung Lee
    Jihye Rhee
    O-Ki Kwon
    Gyojun Hwang
    Cheolkyu Jung
    Yun Jung Bae
    Gwang Seok An
    Kyogu Lee
    Ja-Won Koo
    Jae-Jin Song
    Scientific Reports, 6
  • [3] Dural arteriovenous fistula masquerading as pulsatile tinnitus: radiologic assessment and clinical implications
    An, Yong-Hwi
    Han, Sungjun
    Lee, Minhyung
    Rhee, Jihye
    Kwon, O-Ki
    Hwang, Gyojun
    Jung, Cheolkyu
    Bae, Yun Jung
    An, Gwang Seok
    Lee, Kyogu
    Koo, Ja-Won
    Song, Jae-Jin
    SCIENTIFIC REPORTS, 2016, 6
  • [4] Arteriovenous fistula construction with the VasQ™ external support device: a pilot study
    Chemla, Eric
    Velazquez, Carmen C.
    D'Abate, Fabrizio
    Ramachandran, Veni
    Maytham, Gary
    Journal of Vascular Access, 2016, 17 (03): : 243 - 248
  • [5] Evaluation of arteriovenous fistula for hemodialysis with a new generation digital stethoscope: a pilot study
    Pierangela Presta
    Nazareno Carullo
    Annarita Armeni
    Maria Teresa Zicarelli
    Michela Musolino
    Maria Giovanna Bianco
    Salvatore Chiarella
    Michele Andreucci
    Antonino S. Fiorillo
    Salvatore Andrea Pullano
    Davide Bolignano
    Giuseppe Coppolino
    International Urology and Nephrology, 2024, 56 : 1763 - 1771
  • [6] Evaluation of arteriovenous fistula for hemodialysis with a new generation digital stethoscope: a pilot study
    Presta, Pierangela
    Carullo, Nazareno
    Armeni, Annarita
    Zicarelli, Maria Teresa
    Musolino, Michela
    Bianco, Maria Giovanna
    Chiarella, Salvatore
    Andreucci, Michele
    Fiorillo, Antonino S.
    Pullano, Salvatore Andrea
    Bolignano, Davide
    Coppolino, Giuseppe
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2024, 56 (05) : 1763 - 1771
  • [7] Clinical evaluation of an expert system for arteriovenous fistula assessment
    Chanliau, Jacques
    Charasse, Christophe
    Rose, Cedric
    Bene, Bernard
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (11): : 809 - 815
  • [8] Multimodal angiographic assessment of cerebral arteriovenous malformations: a pilot study
    Blanc, Raphael
    Seiler, Aude
    Robert, Thomas
    Baharvandat, Humain
    Lafarge, Maxime
    Savatovsky, Julien
    Hodel, Jerome
    Ciccio, Gabriele
    Chauvet, Dorian
    Pistocchi, Silvia
    Bartolini, Bruno
    Redjem, Hocine
    Piotin, Michel
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (11) : 841 - 847
  • [9] ARTERIOVENOUS FISTULA OF DURA MATER - CLINICAL AND RADIOLOGICAL STUDY OF 13 CASES
    CASTAIGNE, P
    BORIES, J
    BRUNET, P
    CASSAN, JL
    MEININGER, V
    MERLAND, JJ
    ANNALES DE MEDECINE INTERNE, 1975, 126 (12): : 813 - 817
  • [10] Arteriovenous fistula creation with VasQ™ device: A feasibility study to reveal hemodynamic implications
    Bozzetto, Michela
    Soliveri, Luca
    Poloni, Sofia
    Brambilla, Paolo
    Curto, Diego
    Condemi, Giuseppina Carmela
    Cefali, Pietro
    Spina, Irene
    Villa, Alessandro
    Caroli, Anna
    Remuzzi, Andrea
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (01): : 60 - 70