EXPERIMENTAL CHARACTERIZATION OF SERVER RACK ENERGY USE AT ELEVATED AMBIENT TEMPERATURES

被引:0
|
作者
Iyengar, Madhusudan [1 ]
Schmidt, Roger [1 ]
Kamath, Vinod [2 ]
Kochuparambil, Bejoy [2 ]
机构
[1] IBM Syst & Technol Grp, Poughkeepsie, NY 12601 USA
[2] IBM Syst Technol Grp, Res Triangle Pk, NC 27709 USA
来源
PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2 | 2012年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is now common for data center managers to question the impact on server energy usage of two recent impact factors: (1) the rise in the data center inlet air temperature to servers per 2008 ASHRAE guidelines, and (2) the fan speed increase from the use of rack level heat exchangers such as Rear Door Heat Exchangers. To help acquire a deeper understanding of the relevant issues, a system floor thermal test was built on the IBM New York data center benchmark floor which consisted of a standard 19 '' rack filled with 39 3.0 GHz 1U servers that dissipated between 10-17 kW depending on extent of server utilization. Fan speed, chip temperature metrics, and server power data was collected using product debug codes and server level programs. A simulated air heat load was installed right in front of this server rack to allow the manipulation of air inlet temperature into the servers from 20 degrees C to 32 degrees C. Two different rack level configurations were considered for the experiments: (i) a perforated front door and no door at the rear, and (ii) a perforated front door and a Rear Door Heat Exchanger at the rear. An exerciser program was used to vary the CPU utilization from Idle to 70% which represented a typical data center work load. Data was collected for 19 servers of the 39 servers (remaining were in use by Benchmark Lab) for the two rack configurations, for 4 inlet server air temperatures, and for two chip exerciser settings, i.e. 16 experiments. For the 70% exerciser setting (typical operation) and the base line rack configuration without rack level heat exchangers, the rise in server power for an increase in inlet air temperature was 5.2% for the 20 degrees C to 27 degrees C change and was 17% for the 20 degrees C to 31 degrees C change. For the 70% exerciser setting (typical), the increase in server power from the use of rack level heat exchangers (Rear Door Heat Exchanger) was less than 1.3% for all the conditions. Given the broad range of fan speed algorithms and cooling hardware in server products on the market and their change over each generation, significant further study will be required to characterize each category of systems for these conditions. However, the present study provides a template for quantifying server energy usage in a context that data center managers can understand and use.
引用
收藏
页码:617 / +
页数:3
相关论文
共 50 条
  • [41] USE OF DIAPHRAGM CELL AT ELEVATED TEMPERATURES
    FELL, CJD
    HUTCHISO.HP
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1971, 10 (02): : 303 - &
  • [42] Experimental study of minimum ignition energy of methane/air mixtures at elevated temperatures and pressures
    Cui, Gan
    Zeng, Weiping
    Li, Zili
    Fu, Yang
    Li, Hongbo
    Chen, Jie
    FUEL, 2016, 175 : 257 - 263
  • [43] DESIGN AND DEVELOPMENT OF AN EXPERIMENTAL WROUGHT ALUMINUM-ALLOY FOR USE AT ELEVATED-TEMPERATURES
    POLMEAR, IJ
    COUPER, MJ
    METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1988, 19 (04): : 1027 - 1035
  • [44] Energy use, growth and survival of coral reef snapper larvae reared at elevated temperatures
    McMahon, Shannon J.
    Munday, Philip L.
    Donelson, Jennifer M.
    CORAL REEFS, 2023, 42 (01) : 31 - 42
  • [45] Energy use, growth and survival of coral reef snapper larvae reared at elevated temperatures
    Shannon J. McMahon
    Philip L. Munday
    Jennifer M. Donelson
    Coral Reefs, 2023, 42 : 31 - 42
  • [46] EXPERIMENTAL APPROACH TO A THEORY OF PLASTICITY AT ELEVATED TEMPERATURES
    WRAY, PJ
    RICHMOND, O
    JOURNAL OF APPLIED PHYSICS, 1968, 39 (12) : 5754 - &
  • [47] Tensile Behaviour of Natural Polymer Composite Materials at Ambient and Elevated Temperatures
    Prasanthi, Phani
    Ram, N. Raghu
    Madhav, V. V. Venu
    Agrawal, Manoj Kumar
    Mohanta, Prasanta Kumar
    Saxena, Kuldeep K.
    Chaitanya, Ch Sri
    Salem, Karrar Hazim
    Abdullaeva, Barno Sayfutdinovna
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2023, 30 (02) : 331 - 337
  • [48] Small-scale concrete slab tests at ambient and elevated temperatures
    Bailey, Colin G.
    Toh, Wee Siang
    ENGINEERING STRUCTURES, 2007, 29 (10) : 2775 - 2791
  • [49] Performance of single and hybrid nanoparticles added concrete at ambient and elevated temperatures
    Guler, Soner
    Turkmenoglu, Zehra Funda
    Ashour, Ashraf
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 250 (250)
  • [50] A Study of Plasma-Stabilized Diffusion Flames at Elevated Ambient Temperatures
    Kim, Wookyung
    Do, Hyungrok
    Mungal, M. Godfrey
    Cappelli, Mark A.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (06) : 2898 - 2904