EXPERIMENTAL CHARACTERIZATION OF SERVER RACK ENERGY USE AT ELEVATED AMBIENT TEMPERATURES

被引:0
|
作者
Iyengar, Madhusudan [1 ]
Schmidt, Roger [1 ]
Kamath, Vinod [2 ]
Kochuparambil, Bejoy [2 ]
机构
[1] IBM Syst & Technol Grp, Poughkeepsie, NY 12601 USA
[2] IBM Syst Technol Grp, Res Triangle Pk, NC 27709 USA
来源
PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2 | 2012年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is now common for data center managers to question the impact on server energy usage of two recent impact factors: (1) the rise in the data center inlet air temperature to servers per 2008 ASHRAE guidelines, and (2) the fan speed increase from the use of rack level heat exchangers such as Rear Door Heat Exchangers. To help acquire a deeper understanding of the relevant issues, a system floor thermal test was built on the IBM New York data center benchmark floor which consisted of a standard 19 '' rack filled with 39 3.0 GHz 1U servers that dissipated between 10-17 kW depending on extent of server utilization. Fan speed, chip temperature metrics, and server power data was collected using product debug codes and server level programs. A simulated air heat load was installed right in front of this server rack to allow the manipulation of air inlet temperature into the servers from 20 degrees C to 32 degrees C. Two different rack level configurations were considered for the experiments: (i) a perforated front door and no door at the rear, and (ii) a perforated front door and a Rear Door Heat Exchanger at the rear. An exerciser program was used to vary the CPU utilization from Idle to 70% which represented a typical data center work load. Data was collected for 19 servers of the 39 servers (remaining were in use by Benchmark Lab) for the two rack configurations, for 4 inlet server air temperatures, and for two chip exerciser settings, i.e. 16 experiments. For the 70% exerciser setting (typical operation) and the base line rack configuration without rack level heat exchangers, the rise in server power for an increase in inlet air temperature was 5.2% for the 20 degrees C to 27 degrees C change and was 17% for the 20 degrees C to 31 degrees C change. For the 70% exerciser setting (typical), the increase in server power from the use of rack level heat exchangers (Rear Door Heat Exchanger) was less than 1.3% for all the conditions. Given the broad range of fan speed algorithms and cooling hardware in server products on the market and their change over each generation, significant further study will be required to characterize each category of systems for these conditions. However, the present study provides a template for quantifying server energy usage in a context that data center managers can understand and use.
引用
收藏
页码:617 / +
页数:3
相关论文
共 50 条
  • [1] Experimental Characterization of Pressure Drop in a Server Rack
    Alkharabsheh, Sami
    Sammakia, Bahgat
    Murray, Bruce
    Shrivastava, Saurabh
    Schmidt, Roger
    2014 IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2014, : 547 - 556
  • [2] Experimental Characterization of Immersion-Cooled Devices at Elevated Ambient Temperatures
    Lenke, Robert U.
    Christoph, Martin
    De Doncker, Rik W.
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 493 - 497
  • [3] Effect of Rack Server Population on Temperatures in Data Centers
    Ghosh, Rajat
    Sundaralingam, Vikneshan
    Joshi, Yogendra
    2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 30 - 37
  • [4] ULTRASONIC CHARACTERIZATION OF CERAMIC FIBERS AT AMBIENT AND ELEVATED-TEMPERATURES
    LINDGREN, EA
    ROSEN, M
    AMIN, KE
    ULTRASONICS, 1994, 32 (06) : 411 - 419
  • [5] Characterization of ceramic matrix composite tubes at ambient and elevated temperatures
    Liao, K.
    Elahi, M.
    Reifsnider, K.L.
    Goettler, R.
    Ceramic Engineering and Science Proceedings, 1994, 15 (04): : 233 - 242
  • [6] An Advanced Energy Efficient Rack Server Design
    Pang, Wei
    Wang, Chun
    Ahuja, Nishi
    Zhang, Jun
    Zhou, Alex
    Si, Peifeng
    Song, Youquan
    Zhou, Xiang
    PROCEEDINGS OF THE 2017 SIXTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS ITHERM 2017, 2017, : 806 - 814
  • [7] Experimental behaviour of the reverse channel joint component at elevated and ambient temperatures
    Lopes, Fernanda
    Santiago, Aldina
    da Silva, Luis Simoes
    Heistermann, Tim
    Veljkovic, Milan
    da Silva, Jose Guilherme
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (03) : 459 - 472
  • [8] Experimental behaviour of the reverse channel joint component at elevated and ambient temperatures
    Fernanda Lopes
    Aldina Santiago
    Luís Simões da Silva
    Tim Heistermann
    Milan Veljkovic
    José Guilherme da Silva
    International Journal of Steel Structures, 2013, 13 : 459 - 472
  • [9] THE USE OF COATINGS TO CONTROL FRETTING WEAR AT AMBIENT AND ELEVATED-TEMPERATURES
    HARRIS, SJ
    OVERS, MP
    GOULD, AJ
    WEAR, 1985, 106 (1-3) : 35 - 52
  • [10] Experimental Behaviour of Carbon FRP Reinforced Concrete Beams at Ambient and Elevated Temperatures
    Rafi, Muhammad Masood
    Nadjai, Ali
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2008, 6 (03) : 431 - 441