Disability glare in soft multifocal contact lenses

被引:15
|
作者
Wahl, Siegfried [1 ,2 ]
Fornoff, Luise [1 ,3 ]
Ochakovski, G. Alex [4 ]
Ohlendorf, Arne [1 ,2 ]
机构
[1] Eberhard Karls Univ Tuebingen, Inst Ophthalm Res, Elfriede Aulhorn Str 7, D-72076 Tubingen, Germany
[2] Carl Zeiss Vis Int GmbH, Turnstr 27, D-73430 Aalen, Germany
[3] Univ Appl Sci Aalen, Anton Huber Str 23, D-73430 Aalen, Germany
[4] Univ Eye Hosp, Ctr Ophthalmol, Elfriede Aulhorn Str 7, D-72076 Tubingen, Germany
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 02期
关键词
Contact lens; Optical design; Contrast sensitivity; Disability glare; CONTRAST SENSITIVITY; SPHERICAL-ABERRATION; VISUAL PERFORMANCE; PRESBYOPIA;
D O I
10.1016/j.clae.2017.10.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The study investigated the effect of the design of multifocal contact lenses on the sensitivity to contrast and disability glare. Methods: Contrast sensitivity was measured in 16 young adults (mean age: 25.5 +/- 2.5 years) at a distance of 2 m under two conditions: no-glare and glare. Two designs (Center Near and Center Distance) of the Biofinity soft contact lens were used to simulate correction for presbyopes, while a correction with single vision trial lenses and contact lenses acted as controls. Results: The design of the used multifocal contact lenses had a significant influence on the log area under the curve of the contrast sensitivity function (AUC-CSF). Compared to the spectacle lens correction, the AUC-CSF was significantly reduced, in case CS was measured with the Center Near design lens, under the no-glare (p < 0.001) and the glare condition (p:p < 0.001). In case of the Center Distance design contact lens, the AUC-CSF was significantly smaller in case CS was tested under glare (p = 0.001). Disability glare (DG) was depending on the spatial frequency and the design of the multifocal lens, while the Center Distance design produced higher amounts of DG (p < 0.001), compared to the other used corrections. Conclusion: The optical design of a multifocal contact lenses has a significant impact on the contrast sensitivity as well as the disability glare. In order to dispense the best correction in terms of contact lenses, the sensitivity to contrast under no-glare and glare conditions should be tested a medium spatial frequencies.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 50 条
  • [21] Visual quality of juvenile myopes wearing multifocal soft contact lenses
    Xiaopeng Huang
    Feifu Wang
    Zhiyi Lin
    Yifan He
    Shuyun Wen
    Ling Zhou
    Fan Lu
    Jun Jiang
    Eye and Vision, 7
  • [22] Presbiopia and multifocal contact lenses
    Mancino, R
    Scuderi, G
    Spoto, E
    Catalano, G
    Palma, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S739 - S739
  • [23] Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions
    Garcia-Lazaro, Santiago
    Ferrer-Blasco, Teresa
    Madrid-Costa, David
    Albarran-Diego, Cesar
    Montes-Mico, Robert
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (01): : 19 - 24
  • [24] GLARE-FLARE WITH CONTACT LENSES IN APHAKIA
    KOETTING, RA
    VONGUNTE.TL
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1969, 46 (10): : 730 - &
  • [25] GLARE SENSITIVITY RELATED TO USE OF CONTACT LENSES
    MILLER, D
    WOLF, E
    GEER, S
    VASSALLO, V
    ARCHIVES OF OPHTHALMOLOGY, 1967, 78 (04) : 448 - &
  • [26] Accommodation error with single vision, bifocal and multifocal soft commercial contact lenses
    Bakaraju, Ravi C.
    Fedtke, Cathleen
    Ehrmann, Klaus
    Falk, Darrin
    Chung, Jiyoon
    Ho, Arthur
    Holden, Brien A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [27] Short-term visual performance of soft multifocal contact lenses for presbyopia
    Sha, Jennifer
    Bakaraju, Ravi C.
    Tilia, Daniel
    Chung, Jiyoon
    Delaney, Shona
    Munro, Anna
    Ehrmann, Klaus
    Thomas, Varghese
    Holden, Brien A.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2016, 79 (02) : 73 - 77
  • [28] Impact of primary and secondary spherical aberrations of multifocal soft contact lenses on vision
    Fedtke, Cathleen
    Ehrmann, Klaus
    Thomas, Varghese
    Bakaraou, Ravi Chandra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [29] Light distortion of soft multifocal contact lenses with different pupil size and shape
    Monsalvez-Romin, Daniel
    Gonzalez-Meijome, Jose Manuel
    Esteve-Taboada, Jose J.
    Garcia-Lazaro, Santiago
    Cervino, Alejandro
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (02): : 130 - 136
  • [30] SOFT CONTACT LENSES
    SAYLOR, LF
    CALIFORNIA MEDICINE, 1971, 115 (02): : 96 - &