Disability glare in soft multifocal contact lenses

被引:15
|
作者
Wahl, Siegfried [1 ,2 ]
Fornoff, Luise [1 ,3 ]
Ochakovski, G. Alex [4 ]
Ohlendorf, Arne [1 ,2 ]
机构
[1] Eberhard Karls Univ Tuebingen, Inst Ophthalm Res, Elfriede Aulhorn Str 7, D-72076 Tubingen, Germany
[2] Carl Zeiss Vis Int GmbH, Turnstr 27, D-73430 Aalen, Germany
[3] Univ Appl Sci Aalen, Anton Huber Str 23, D-73430 Aalen, Germany
[4] Univ Eye Hosp, Ctr Ophthalmol, Elfriede Aulhorn Str 7, D-72076 Tubingen, Germany
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 02期
关键词
Contact lens; Optical design; Contrast sensitivity; Disability glare; CONTRAST SENSITIVITY; SPHERICAL-ABERRATION; VISUAL PERFORMANCE; PRESBYOPIA;
D O I
10.1016/j.clae.2017.10.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The study investigated the effect of the design of multifocal contact lenses on the sensitivity to contrast and disability glare. Methods: Contrast sensitivity was measured in 16 young adults (mean age: 25.5 +/- 2.5 years) at a distance of 2 m under two conditions: no-glare and glare. Two designs (Center Near and Center Distance) of the Biofinity soft contact lens were used to simulate correction for presbyopes, while a correction with single vision trial lenses and contact lenses acted as controls. Results: The design of the used multifocal contact lenses had a significant influence on the log area under the curve of the contrast sensitivity function (AUC-CSF). Compared to the spectacle lens correction, the AUC-CSF was significantly reduced, in case CS was measured with the Center Near design lens, under the no-glare (p < 0.001) and the glare condition (p:p < 0.001). In case of the Center Distance design contact lens, the AUC-CSF was significantly smaller in case CS was tested under glare (p = 0.001). Disability glare (DG) was depending on the spatial frequency and the design of the multifocal lens, while the Center Distance design produced higher amounts of DG (p < 0.001), compared to the other used corrections. Conclusion: The optical design of a multifocal contact lenses has a significant impact on the contrast sensitivity as well as the disability glare. In order to dispense the best correction in terms of contact lenses, the sensitivity to contrast under no-glare and glare conditions should be tested a medium spatial frequencies.
引用
收藏
页码:175 / 179
页数:5
相关论文
共 50 条
  • [1] Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses
    Pieh, S
    Weghaupt, H
    Skorpik, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05): : 659 - 662
  • [2] MULTIFOCAL INTRAOCULAR LENSES AND GLARE
    AKUTSU, H
    LEGGE, GE
    LUEBKER, A
    LINDSTROM, RL
    ZABEL, RW
    KIRBY, VM
    OPTOMETRY AND VISION SCIENCE, 1993, 70 (06) : 487 - 495
  • [3] The Effect of Multifocal Soft Contact Lenses on Peripheral Refraction
    Kang, Pauline
    Fan, Yvonne
    Oh, Kelly
    Trac, Kevin
    Zhang, Frank
    Swarbrick, Helen A.
    OPTOMETRY AND VISION SCIENCE, 2013, 90 (07) : 658 - 666
  • [4] Retardation of Myopia Progression by Multifocal Soft Contact Lenses
    Zhu, Qin
    Liu, Yongsong
    Tighe, Sean
    Zhu, Yingting
    Su, Xuanbo
    Lu, Fabing
    Hu, Min
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2019, 16 (02): : 198 - 202
  • [5] Power Profiles of Commercial Multifocal Soft Contact Lenses
    Kim, Eon
    Bakaraju, Ravi C.
    Ehrmann, Klaus
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (02) : 183 - 196
  • [6] Soft multifocal simultaneous image contact lenses: a review
    Perez-Prados, Roque
    Pinero, David P.
    Perez-Cambrodi, Rafael J.
    Madrid-Costa, David
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (02) : 107 - 127
  • [7] Peripheral defocus with spherical and multifocal soft contact lenses
    Berntsen, D.A. (dberntsen@optometry.uh.edu), 1600, Lippincott Williams and Wilkins (90):
  • [8] Peripheral Defocus with Spherical and Multifocal Soft Contact Lenses
    Berntsen, David A.
    Kramer, Carl E.
    OPTOMETRY AND VISION SCIENCE, 2013, 90 (11) : 1215 - 1224
  • [9] GLARE DISABILITY IN EYES WITH INTRAOCULAR LENSES
    NADLER, DJ
    JAFFE, NS
    CLAYMAN, HM
    JAFFE, MS
    LUSCOMBE, SM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 97 (01) : 43 - 47
  • [10] Visual performance of daily disposable multifocal soft contact lenses
    Sha, Jennifer
    Tilia, Daniel
    Kho, Danny
    Diec, Jennie
    Yeotikar, Nisha
    Jong, Monica
    Thomas, Varghese
    Bakaraju, Ravi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)