Predictors of external cooling failure after cardiac arrest

被引:9
|
作者
Ricome, Sylvie [1 ,3 ]
Dumas, Florence [2 ,4 ]
Mongardon, Nicolas [1 ,3 ]
Varenne, Olivier [5 ]
Fichet, Jerome [1 ,3 ]
Pene, Frederic [1 ,3 ]
Zuber, Benjamin [1 ,3 ]
Vivien, Benoit [6 ]
Charpentier, Julien [1 ]
Chiche, Jean-Daniel [1 ,3 ]
Mira, Jean-Paul [1 ,3 ]
Cariou, Alain [1 ,2 ,3 ]
机构
[1] Grp Hosp Cochin Broca Hotel Dieu, Med Intens Care Unit, Cochin Hosp, AP HP, F-75014 Paris, France
[2] Paris Descartes Univ, INSERM, U970, Paris Cardiovasc Res Ctr PARCC, Paris, France
[3] Univ Paris 05, Fac Med, F-75006 Paris, France
[4] Grp Hosp Cochin Broca Hotel Dieu, Cochin Hosp, AP HP, Dept Emergency Med, F-75014 Paris, France
[5] Grp Hosp Cochin Broca Hotel Dieu, Cochin Hosp, AP HP, Dept Cardiol, F-75014 Paris, France
[6] Hop Necker Enfants Malad, AP HP, SAMU 75, F-75015 Paris, France
关键词
Cardiac arrest; Resuscitation; Therapeutic hypothermia; INTERNATIONAL LIAISON COMMITTEE; EUROPEAN RESUSCITATION COUNCIL; AMERICAN-HEART-ASSOCIATION; PERCUTANEOUS CORONARY INTERVENTION; THERAPEUTIC HYPOTHERMIA; CARDIOPULMONARY-RESUSCITATION; STROKE FOUNDATION; RAPID INDUCTION; TASK-FORCE; CARE;
D O I
10.1007/s00134-012-2794-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
External cooling is largely employed to induce hypothermia in comatose survivors of cardiac arrest (CA), but can fail to reach the target temperature in a reasonable time. We aimed to assess the rate of failure of external cooling after CA and to determine failure predictors. The study was a retrospective review of a prospectively acquired database in the setting of a 24-bed ICU in a university hospital. All consecutive patients admitted for CA from May 2002 to April 2010 and treated by external cooling were considered. Patients who were already hypothermic on admission, patients dying within 24 h, patients cooled by an internal technique and patients in whom hypothermia had not been attempted were not studied. External cooling failure was defined as the inability to reach a temperature below 34 A degrees C during the first 12 h after CA onset. Among 1,036 patients admitted to the ICU, 594 were included in the analysis and in 191 (32 %) the target temperature could not be achieved within the 12 h following CA. Independent risk factors for external cooling failure were an early coronary angiography intervention (OR 3.75, p < 0.001), a high body weight (OR 1.02 per kilogram, p = 0.007), a high temperature on ICU admission (OR 1.47 per degree, p = 0.001) and a long delay between collapse and the start of cooling (OR 1.15, p = 0.05). Conversely, early haemodialysis (OR 0.27, p < 0.001) and male gender (OR 0.47, p = 0.02) were significantly associated with cooling success. External cooling failure occurred in nearly one-third of patients with CA and was associated with easily identified risk factors. This emphasizes the interest in early cooling and alternative techniques in these patients.
引用
收藏
页码:620 / 628
页数:9
相关论文
共 50 条
  • [41] Predictors of survival after cardiac or respiratory arrest in critical care units
    Kutsogiannis, Demetrios J.
    Bagshaw, Sean M.
    Laing, Bryce
    Brindley, Peter G.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2011, 183 (14) : 1589 - 1595
  • [42] Automated External Defibrillators and Survival After In-Hospital Cardiac Arrest
    Chan, Paul S.
    Krumholz, Harlan M.
    Spertus, John A.
    Jones, Philip G.
    Cram, Peter
    Berg, Robert A.
    Nadkarni, Vinay
    Peberdy, MaryAnn
    Mancini, Mary E.
    Nallamothu, Brahmajee K.
    CIRCULATION, 2010, 122 (21)
  • [43] THE IMPACT OF ORGAN FAILURE ON OUTCOME OF PATIENTS AFTER CARDIAC ARREST
    Nobile, L.
    Taccone, F. S.
    Sakr, V.
    Szakmany, T.
    Fletcher, N.
    Jakob, S.
    Beardow, Z.
    Vincent, J. -L.
    INTENSIVE CARE MEDICINE, 2014, 40 : S216 - S216
  • [44] Survival after resuscitated cardiac arrest in patients with heart failure
    Moreno, A. CAna Cristina Perez
    Degnan, A.
    Mcmurray, J. J. V.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 313 - 313
  • [45] Exploratory Feasibility Study of Cerebral Cooling by Transpulmonary Cooling During Cardiac Arrest in a Swine Cardiac Arrest Model
    Sakurai, Atsushi
    Kato, Yoshihisa
    Uki, Haruka
    Yagi, Kana
    Watanabe, Atsushi
    Sato, Jun
    Nakagawa, Katsuhiro
    Nakabayashi, Hayato
    Kinoshita, Kosaku
    THERAPEUTIC HYPOTHERMIA AND TEMPERATURE MANAGEMENT, 2024,
  • [46] Cardiac arrest predictors in cardiogenic shock
    Santos, H.
    Vieira, T.
    Fernandes, J.
    Pinto, R.
    Filipa, T.
    Ferreira, A. R.
    Rios, M.
    Honrado, T.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 453 - 453
  • [47] Predictors of Outcome Post Cardiac Arrest
    Bigham, S.
    Bigham, C.
    Martin, D.
    JOURNAL OF INTENSIVE CARE MEDICINE, 2018, 33 (04) : 248 - 255
  • [48] ELECTROCARDIOGRAPHIC PREDICTORS OF IN -HOSPITAL CARDIAC ARREST
    Tiecher, Ricardo Dahmer
    Do, Duc
    Bai, Yong
    Hu, Xiao
    Boyle, Noel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A339 - A339
  • [49] Safety Concerns in Intravascular Cooling for Targeted Temperature Management After Cardiac Arrest
    Honore, Patrick M.
    Blackman, Sydney
    Perriens, Emily
    Bousbiat, Ibrahim
    CRITICAL CARE MEDICINE, 2023, 51 (08) : E174 - E175
  • [50] Randomized comparison of surface- and invasive cooling after sudden cardiac arrest
    Pittl, U.
    Schratter, A.
    Klemm, T.
    Lehmann, D.
    Demmin, K.
    Schuler, G.
    Mende, M.
    Thiele, H.
    EUROPEAN HEART JOURNAL, 2010, 31 : 900 - 900