Characterization of polarimetric based three axis atomic magnetometer

被引:16
|
作者
Pradhan, Swarupananda [1 ,2 ]
Behera, Rita [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Laser & Plasma Technol Div, Mumbai 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, Maharashtra, India
关键词
Atomic magnetometer; Bloch equation; Laser frequency stabilization; Polarimetry; Lissajous plot;
D O I
10.1016/j.sna.2019.03.004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The operation of polarimetric based single beam three axis atomic magnetometer is studied. The magnetometer operates in presence of small bias magnetic field. Its salient features are compared with the analysis of Bloch equation. The sensitivity of the device along three orthogonal directions are measured in low frequency regime, where 1/f noise adversely affect the sensitivity. The crosstalk among the three axes magnetic field measurements and relative phase shifts are analysed using Lissajous plot. The sensitivity of the magnetometer is found to be < 20 pT Hz(-1/2) @400 mHz in any direction. The investigated magnetometer is suitable for space application, where overall size of the device is of prime importance. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [31] Low-Frequency Characterization of MEMS-based Portable Atomic Magnetometer
    Mhaskar, Rahul R.
    Knappe, Svenja
    Kitching, John
    2010 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2010, : 376 - 379
  • [32] Error calibration of three axis magnetometer based on Global Artificial Fish Swarm Algorithm
    Gong Xiaowen
    Song Zhongguo
    Xi Xiaoli
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [33] Ground based modeling and real time On-board calibration of a three axis magnetometer
    Prasad, Nishanth K.
    Kumar, Saroj
    Dasiga, Sankar
    Ravindra, H. S.
    Maji, Amit
    2014 IEEE AEROSPACE CONFERENCE, 2014,
  • [34] Single-light-source three-axis atomic magnetometer based on orthogonal and non-overlapping dual-pump beams
    Li, Lin
    Tang, Junjian
    Zhao, Binbin
    Zhai, Yueyang
    RESULTS IN PHYSICS, 2023, 51
  • [35] Field optimization method of a dual-axis atomic magnetometer based on frequency-response and dynamics
    Xing, Li
    Quan, Wei
    Fan, Wenfeng
    Li, Rujie
    Jiang, Liwei
    Fang, Jiancheng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (05)
  • [36] Miniature Three-Axis Induction Magnetometer for Borehole Logging
    Yan, Bin
    Zhu, Wanhua
    Zhuang, Xin
    Liu, Leisong
    Fang, Guangyou
    IEEE MAGNETICS LETTERS, 2019, 10
  • [37] High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement
    Tang, Junjian
    Zhai, Yueyang
    Cao, Li
    Zhang, Yaohua
    Li, Lin
    Zhao, Binbin
    Zhou, Binquan
    Han, Bangcheng
    Liu, Gang
    OPTICS EXPRESS, 2021, 29 (10) : 15641 - 15652
  • [38] Three-axis absolute magnetometer utilizing weak localization
    Rasmussen, FB
    Baklanov, K
    Hassenkam, T
    Pedersen, S
    Sorensen, CB
    Lindelof, PE
    Vuorinen, RT
    Lipinski, L
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1996, 46 : 2773 - 2774
  • [39] Three-Axis Vector Magnetometer with a Three-Dimensional Flux Concentrator
    Chen, Shih-Jui
    Hong, Der-Tai
    Hsieh, Ping-Hsun
    Wang, Tse-Kang
    SENSORS, 2024, 24 (05)
  • [40] Spacecraft attitude determination and three-axis magnetometer calibration
    Huang, Lin
    Jing, Wu-Xing
    Yuhang Xuebao/Journal of Astronautics, 2008, 29 (03): : 854 - 859