Flame Heights of Di-tert-butyl Peroxide Pool Fires - Experimental Study and Modelling

被引:4
|
作者
Schaelike, Stefan [1 ,2 ]
Wehrstedt, Klaus-Dieter [1 ]
Schoenbucher, Axel [2 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Unter Eichen 87, D-12205 Berlin, Germany
[2] Univ Duisburg Essen, Inst Chem Engn, D-45141 Essen, Germany
关键词
D O I
10.3303/CET1226061
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The flame heights of di-tert-butyl peroxide (DTBP) pool fires with diameters between 0.03 m < d < 3 m are determined by means of visible images obtained by a VHS video recorder. The time-averaged H-av and maximum flame height H-max were evaluated according to the intermittency criterion. For the relative time-averaged flame heights values in a range of 3.1 < H-av/d < 14.8 are obtained while the relative maximum flame heights are in a range of 3.5 < H-max/d < 17.6. The experimental measurements were used to establish a new Froude number correlation.
引用
收藏
页码:363 / 368
页数:6
相关论文