A rapid and accurate method, ventilated chamber C-history method, of measuring the emission characteristic parameters of formaldehyde/VOCs in building materials

被引:56
|
作者
Huang, Shaodan [1 ]
Xiong, Jianyin [2 ]
Zhang, Yinping [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Volatile organic compounds (VOCs); Formaldehyde; Building material; C-history method; Indoor air quality (IAQ); VOLATILE ORGANIC-COMPOUNDS; INITIAL EMITTABLE CONCENTRATION; PARTITION-COEFFICIENTS; ANALYTICAL-MODEL; DIFFUSION-COEFFICIENTS; VOC EMISSIONS; TEMPERATURE; SORPTION; CARPETS; IMPACT;
D O I
10.1016/j.jhazmat.2013.08.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The indoor pollution caused by formaldehyde and volatile organic compounds (VOCs) emitted from building materials poses an adverse effect on people's health. It is necessary to understand and control the behaviors of the emission sources. Based on detailed mass transfer analysis on the emission process in a ventilated chamber, this paper proposes a novel method of measuring the three emission characteristic parameters, i.e., the initial emittable concentration, the diffusion coefficient and the partition coefficient. A linear correlation between the logarithm of dimensionless concentration and time is derived. The three parameters can then be calculated from the intercept and slope of the correlation. compared with the closed chamber C-history method, the test is performed under ventilated condition thus some commonly-used measurement instruments (e.g., GC/MS, HPLC) can be applied. While compared with other methods, the present method can rapidly and accurately measure the three parameters, with experimental time less than 12 h and R-2 ranging from 0.96 to 0.99 for the cases studied. Independent experiment was carried out to validate the developed method, and good agreement was observed between the simulations based on the determined parameters and experiments. The present method should prove useful for quick characterization of formaldehyde/VOC emissions from indoor materials. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:542 / 549
页数:8
相关论文
共 38 条
  • [21] Accurate Method for Measuring the Characteristic Parameters and the Phase Center of the Circularly Polarized Antennas
    Shang, Junping
    Fan, Chaoyang
    2018 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2018, : 1403 - 1404
  • [22] Variable Volume Loading Method: A Convenient and Rapid Method for Measuring the Initial Emittable Concentration and Partition Coefficient of Formaldehyde and Other Aldehydes in Building Materials
    Xiong, Jianyin
    Yan, Wei
    Zhang, Yinping
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (23) : 10111 - 10116
  • [23] A new method of measuring VOC emission characteristics of dry building materials
    Wang, QY
    Zhang, YP
    Wang, XK
    Zhao, RY
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1316 - 1321
  • [24] A rapid micro chamber method to measure SVOC emission and transport model parameters
    Wang, Chunyi
    Eichler, Clara M. A.
    Bi, Chenyang
    Delmaar, Christiaan J. E.
    Xu, Ying
    Little, John C.
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2023, 25 (04) : 818 - 831
  • [25] Accurate measurement of the radon exhalation rate of building materials using the closed chamber method
    Zhang, Lei
    Lei, Xing
    Guo, Qiuju
    Wang, Shanqiang
    Ma, Xinhua
    Shi, Zhilan
    JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (03) : 315 - 323
  • [26] New method for determining VOC emission parameters for dry building materials
    Department of Building Science, Tsinghua University, Beijing 100084, China
    Huagong Xuebao, 2006, SUPPL. (182-186):
  • [27] A FAST AND ACCURATE METHOD FOR MEASURING RADON EXHALATION RATES FROM BUILDING-MATERIALS
    INGERSOLL, JG
    STITT, BD
    ZAPALAC, GH
    HEALTH PHYSICS, 1983, 45 (02): : 550 - 552
  • [28] A REGRESSION METHOD FOR MEASURING INITIAL MOBILE FORMALDEHYDE CONCENTRATION AND PARTITION COEFFICIENT OF DRY BUILDING MATERIALS
    Yan, Wei
    Zhang, Yinping
    Xiong, Jianyin
    Wang, Xinke
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 90 - 97
  • [29] Method of measuring the mechanical properties of ferromagnetic materials based on magnetostrictive EMAT characteristic parameters
    Wang, Ping
    Zhang, Yuan
    Yao, Entao
    Mi, Yan
    Zheng, Yang
    Tang, Chenglong
    MEASUREMENT, 2021, 168
  • [30] Study on a new charcoal closed chamber method for measuring radon exhalation rate of building materials
    Song Yanchao
    Wang Junlin
    Shang Bing
    Cui Hongxing
    Wu Yunyun
    RADIATION MEASUREMENTS, 2020, 134