Unsupervised Non-Intrusive Energy Disaggregation for Commercial Buildings

被引:0
|
作者
Hossain, Mohammad A. [1 ]
Khalilnejad, Arash [1 ]
Swanson, Rachel A. [1 ]
Mousseau, Jack [1 ]
Pickering, Ethan M. [1 ,2 ]
French, Roger H. [3 ]
Abramson, Alexis R. [4 ]
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] CALTECH, Pasadena, CA 91125 USA
[3] Case Western Reserve Univ, Dept Mat Sci & Engn, Cleveland, OH 44106 USA
[4] Case Western Reserve Univ, Mech & Aerosp Engn, Cleveland, OH 44106 USA
来源
2017 ASHRAE ANNUAL CONFERENCE PAPERS | 2017年
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Commercial buildings alone are responsible for 36% of the total United States electricity consumption, and 30% of this electricity consumption is wasted on average. One of the greatest challenges in improving building energy efficiency lies in the ability to do simple and non-intrusive load disaggregation. In this paper, we propose a novel unsupervised, non-intrusive building energy disaggregation technique using only 15-minute interval whole-building energy consumption and weather data. The proposed disaggregation technique consists of an analysis loop with three steps. Step 1 analyzes the change in energy consumption in 15-minute intervals for every 3 degrees C temperature range to identify statistically significant temperature dependent and independent the equipment turn on-off states. In step 2, a probabilistic approach is developed using a Factorial Hidden Markov Model (FHMM) that combines equipment state transition matrices from the equipment turn on-off states of step 1 and an emission matrix representing all possible combinations of equipment energy consumption in each state. In step 3, FHMM identifies the best possible combinations of the equipment state and consumption for every point in time using an Expectation Maximization (EM) algorithm. Ultimately, specific equipment such as HVAC, plug load, and lighting, can be identified virtually without setting foot in the building. The proposed disaggregation technique is validated by comparing real-world, sub-metered building equipment energy consumption data to the whole building data. The results show that the method achieves at least 80% accuracy. Using the disaggregation technique to identify the breakdown of HVAC, lighting, and plug load, we compare the results from building population studies to identify potential areas of energy waste and generate an automated virtual energy audit report. The report provides personalized building recommendations such as improving HVAC operations, lighting, and equipment scheduling, including a measure of potential return-on-investment
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Non-Intrusive Load Monitoring (NILM) for Energy Disaggregation Using Soft Computing Techniques
    Puente, Cristina
    Palacios, Rafael
    Gonzalez-Arechavala, Yolanda
    Francisco Sanchez-Ubeda, Eugenio
    ENERGIES, 2020, 13 (12)
  • [22] A Non-Intrusive Low-Cost Kit for Electric Power Measuring and Energy Disaggregation
    Quindai, Randy
    Barbosa, Bruno M.
    Almeida, Charles M. P.
    Ramos, Heitor S.
    Rodrigues, Joel J. P. C.
    Aquino, Andre L. L.
    JOURNAL OF COMMUNICATIONS SOFTWARE AND SYSTEMS, 2018, 14 (01) : 9 - 17
  • [23] Non-intrusive load monitoring techniques for the disaggregation of ON/OFF appliances
    Marco Castangia
    Angelica Urbanelli
    Awet Abraha Girmay
    Christian Camarda
    Enrico Macii
    Edoardo Patti
    Energy Informatics, 5
  • [24] Towards Light Intensity Assisted Non-Intrusive Electricity Disaggregation
    Wang, Jue
    Jazizadeh, Farrokh
    COMPUTING IN CIVIL ENGINEERING 2017: SENSING, SIMULATION, AND VISUALIZATION, 2017, : 179 - 186
  • [25] A comprehensive study of the techniques used in non-intrusive load disaggregation
    Jadhav, P. R.
    Rao, Ritesh
    Vhatkar, Sourabh
    2017 INTERNATIONAL CONFERENCE ON ALGORITHMS, METHODOLOGY, MODELS AND APPLICATIONS IN EMERGING TECHNOLOGIES (ICAMMAET), 2017,
  • [26] Non-Intrusive Load Disaggregation Using Graph Signal Processing
    He, Kanghang
    Stankovic, Lina
    Liao, Jing
    Stankovic, Vladimir
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (03) : 1739 - 1747
  • [27] Non-intrusive Load Disaggregation Based on Kernel Density Estimation
    Wang Sen
    Yang Dongsheng
    Guo Chuchen
    Du Shengxian
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [28] An improved non-intrusive load disaggregation algorithm and its application
    Liu, Hui
    Yu, Chengming
    Wu, Haiping
    Chen, Chao
    Wang, Ziqi
    SUSTAINABLE CITIES AND SOCIETY, 2020, 53
  • [29] Non-Intrusive A/C Load Disaggregation Using Deep Learning
    Cho, Jin
    Hu, Zhen
    Sartipi, Mina
    2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [30] Power signature-based non-intrusive load disaggregation
    Li, Jiaming
    West, Sam
    Platt, Glenn
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2013, 20 (01) : 16 - 24