Impact of model-based iterative reconstruction (MBIR) on image quality in cerebral CT angiography before and after intracranial aneurysm treatment

被引:8
|
作者
Hajdu, Steven David [1 ]
Daniel, Roy Thomas [2 ]
Meuli, Reto Antoine [1 ]
Zerlauth, Jean-Baptiste [1 ]
Dunet, Vincent [1 ]
机构
[1] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, Rue Bugnon 46, CH-1003 Lausanne, Switzerland
[2] Lausanne Univ Hosp, Dept Neurosurg, Lausanne, Switzerland
关键词
Computed tomography; Intracranial aneurysm; Image reconstruction; Angiography; Surgical clip; METAL ARTIFACT REDUCTION; LOW TUBE VOLTAGE; CRANIAL CT; FOLLOW-UP;
D O I
10.1016/j.ejrad.2018.03.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To subjectively and objectively assess the impact of model-based iterative reconstruction(MBIR) on image quality in cerebral computed tomography angiography compared to adaptive statistical iterative reconstruction (ASIR). Methods: 107 patients (mean age: 58 +/- 14 years) were included prior to (n = 38) and after (n = 69) intracranial aneurysm treatment. Images were acquired using a routine protocol and reconstructed with MBIR and ASIR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios in the internal carotid and middle cerebral arteries were compared between MBIR and ASIR using the Wilcoxon signed-rank test. Additionally, two neuroradiologists subjectively assessed noise, artefacts, vessel sharpness and overall quality using a semi-quantitative assessment scale. Results: Objective assessment revealed that MBIR reduced noise (p < 0.0001) and additionally improved SNR (p < 0.0001) and CNR (p < 0.0001) compared to ASIR in untreated and treated patients. Subjective assessment revealed that in untreated patients, MBIR improved noise reduction, artefacts, vessel sharpness and overall quality relative to ASIR (p < 0.0001). In the treated groups, noise and vessel sharpness were improved (p < 0.0001) with no change in artefacts on images reconstructed with MBIR compared to ASIR. Conclusion: MBIR significantly improves noise, SNR, CNR and vessel sharpness in untreated and treated patients with intracranial aneurysms. MBIR does not reduce artefacts generated by metallic devices following intracranial aneurysm treatment.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [21] Utility of follow-up ultra-high-resolution CT angiography with model-based iterative reconstruction after flow diverter treatment for cerebral aneurysms
    Iwata, Naoki
    Sakamoto, Makoto
    Sakou, Toshio
    Uno, Tetsuji
    Kurosaki, Masamichi
    RADIOLOGIA MEDICA, 2023, 128 (10): : 1262 - 1270
  • [22] Neointimal formation after carotid artery stenting: phantom and clinical evaluation of model-based iterative reconstruction (MBIR)
    Kazushi Yokomachi
    Fuminari Tatsugami
    Toru Higaki
    Shinji Kume
    Shigeyuki Sakamoto
    Takahito Okazaki
    Kaoru Kurisu
    Yuko Nakamura
    Yasutaka Baba
    Makoto Iida
    Kazuo Awai
    European Radiology, 2019, 29 : 161 - 167
  • [23] Image Quality in Children with Low-Radiation Chest CT Using Adaptive Statistical Iterative Reconstruction and Model-Based Iterative Reconstruction
    Sun, Jihang
    Peng, Yun
    Duan, Xiaomin
    Yu, Tong
    Zhang, Qifeng
    Liu, Yong
    Hu, Di
    PLOS ONE, 2014, 9 (05):
  • [24] Quantifying Differences in Image Quality Between Filtered Backprojection, An Adaptive Iterative Reconstruction Algorithm, and a Model-Based Iterative Reconstruction Algorithm for CT
    Whitson, H.
    Griglock, T.
    DeWeese, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3113 - 3113
  • [25] Model-Based Iterative Reconstruction in CT Enterography
    Murphy, Kevin P.
    Crush, Lee
    Twomey, Maria
    McLaughlin, Patrick D.
    Mildenberger, Iris C.
    Moore, Niamh
    Bye, Jackie
    O'Connor, Owen J.
    McSweeney, Sean E.
    Shanahan, Fergus
    Maher, Michael M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (06) : 1173 - 1181
  • [26] Clinical impact of model-based type iterative reconstruction with fast reconstruction time on image quality of low-dose screening chest CT
    Yuki, Hideaki
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Namimoto, Tomohiro
    Katahira, Kazuhiro
    Honda, Keiichi
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2016, 57 (03) : 295 - 302
  • [27] Improving image quality with model-based iterative reconstruction at quarter of nominal dose in upper abdominal CT
    Zhang, Xirong
    Chen, Jing
    Yu, Nan
    Ren, Zhanli
    Tian, Qian
    Tian, Xin
    He, Taiping
    Guo, Changyi
    BRITISH JOURNAL OF RADIOLOGY, 2018, 92 (1093):
  • [28] Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT
    Smith, Ethan A.
    Dillman, Jonathan R.
    Goodsitt, Mitchell M.
    Christodoulou, Emmanuel G.
    Keshavarzi, Nahid
    Strouse, Peter J.
    RADIOLOGY, 2014, 270 (02) : 526 - 534
  • [29] Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose
    Aurumskjold, Marie-Louise
    Soderberg, Marcus
    Stalhammar, Fredrik
    von Steyern, Kristina Vult
    Tingberg, Anders
    Ydstrom, Kristina
    ACTA RADIOLOGICA, 2018, 59 (06) : 740 - 747
  • [30] Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling-improved image quality by iterative metal artifact reduction
    Bier, Georg
    Bongers, Malte Niklas
    Hempel, Johann-Martin
    Oergel, Anja
    Hauser, Till-Karsten
    Ernemann, Ulrike
    Hennersdorf, Florian
    NEURORADIOLOGY, 2017, 59 (07) : 649 - 654