Objective and Subjective Image Quality of Liver Prechyma and Hepatic Metastass with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor

被引:53
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Meyer, Mathias [1 ]
Fink, Christian [3 ]
Hohenberger, Peter [4 ]
Leidecker, Christianne [5 ]
Schoenberg, Stefan O. [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[3] Gen Hosp Celle, Dept Radiol, Celle, Germany
[4] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Dept Surg,Div Surg Oncol & Thorac Surg, D-68167 Mannheim, Germany
[5] Siemens Healthcare Sect, Forchheim, Germany
关键词
Dual-source CT; dual-energy CT; gastrointestinal stromal tumor; hepatic metastasis; virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; CRITERIA; FUSION; RECIST; CHOI;
D O I
10.1016/j.acra.2014.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare in dual-energy CT (DECT) conventionally reconstructed polyenergetic images (PEI) at 120 kVp to virtual monoenergetic images (MEI) at different kiloelectron volt (key) levels for evaluation of liver and gastrointestinal stromal tumor (GIST) hepatic metastases with regard to objective (IQob) and subjective image quality (IQsub) assessed by two readers of varying experience. Image quality was correlated to patient size and compared between PEI and MEI. Materials and Methods: From 50 examinations of 17 GIST patients (12 with hepatic metastases) undergoing abdominal dual-source DECT for staging, therapy monitoring or follow-up, PEI and nine MEI in 10-keV intervals from 40 to 120 keV were reconstructed. Liver contrast-to-noise ratios (CNR) and metastasis-to-liver ratios were calculated. MEI reconstructions with the highest IQob were compared to PEI for IQsub by one experienced reader (ER) and one inexperienced reader (IR). Patients' diameters were correlated to IQob and IQsub ratings. Results: MEI at 70 keV had the highest IQob with equal liver CNR and metastasis-to-liver ratio compared to PEI. The ER rated 70-keV MEI and PEI equally high (median 4), whereas the IR rated IQsub best in 70-keV MEI (median 5). Unlike in PEI, IQsub ratings in 70-keV MEI were not correlated to patient size. Conclusions: MEI at 70 keV provided an IQob equivalent to PEI. Regarding the IR, IQsub was improved in 70-keV MEI compared to PEI and less dependent on patient size. Therefore, IRs might improve their diagnostic confidence in the assessment of hepatic GIST metastases by evaluating MEI reconstructions at 70 keV.
引用
收藏
页码:514 / 522
页数:9
相关论文
共 50 条
  • [31] Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods
    Ueguchi, Takashi
    Ogihara, Ryota
    Yamada, Sachiko
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1632 - 1639
  • [32] Impact of deep learning reconstructions on image quality and liver lesion detectability in dual-energy CT: An anthropomorphic phantom study
    Pauthe, Aurelie
    Milliner, Milan
    Pasquier, Hugo
    Campagnolo, Lucie
    Mule, Sebastien
    Luciani, Alain
    MEDICAL PHYSICS, 2025,
  • [33] Low-keV virtual monoenergetic imaging reconstructions of excretory phase spectral dual-energy CT in patients with urothelial carcinoma: A feasibility study
    Zopfs, David
    Laukamp, Kai Roman
    dos Santos, Daniel Pinto
    Sokolowski, Marcel
    Hokamp, Nils Grosse
    Maintz, David
    Borggrefe, Jan
    Persigehl, Thorsten
    Lennartz, Simon
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 : 135 - 143
  • [34] Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality
    Matsubara, Kosuke
    Takata, Tadanori
    Kobayashi, Masanao
    Kobayashi, Satoshi
    Koshida, Kichiro
    Gabata, Toshifumi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (02) : 354 - 361
  • [35] Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT
    Wichmann, Julian L.
    Hardie, Andrew D.
    Schoepf, U. Joseph
    Felmly, Lloyd M.
    Perry, Jonathan D.
    Varga-Szemes, Akos
    Mangold, Stefanie
    Caruso, Damiano
    Canstein, Christian
    Vogl, Thomas J.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 642 - 650
  • [36] Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study
    Abdellatif, Waleed
    Esslinger, Eric
    Kobes, Kevin
    Wong, Amanda
    Powell, Jennifer
    Ali, Ismail Tawakol
    Andrews, Gordon
    Nicolaou, Savvas
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2712 - 2721
  • [37] Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study
    Waleed Abdellatif
    Eric Esslinger
    Kevin Kobes
    Amanda Wong
    Jennifer Powell
    Ismail Tawakol Ali
    Gordon Andrews
    Savvas Nicolaou
    European Radiology, 2020, 30 : 2712 - 2721
  • [38] Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT
    Julian L. Wichmann
    Andrew D. Hardie
    U. Joseph Schoepf
    Lloyd M. Felmly
    Jonathan D. Perry
    Akos Varga-Szemes
    Stefanie Mangold
    Damiano Caruso
    Christian Canstein
    Thomas J. Vogl
    Carlo N. De Cecco
    European Radiology, 2017, 27 : 642 - 650
  • [39] Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma
    Martin, Simon S.
    Wichmann, Julian L.
    Pfeifer, Sophia
    Leithner, Doris
    Lenga, Lukas
    Reynolds, Michael A.
    D'Angelo, Tommaso
    Hammerstingl, Renate
    Gruber-Rouh, Tatjana
    Vogl, Thomas J.
    Albrecht, Moritz H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 97 : 1 - 7
  • [40] Deep learning–based image reconstruction of 40-keV virtual monoenergetic images of dual-energy CT for the assessment of hypoenhancing hepatic metastasis
    Taehee Lee
    Jeong Min Lee
    Jeong Hee Yoon
    Ijin Joo
    Jae Seok Bae
    Jeongin Yoo
    Jae Hyun Kim
    Chulkyun Ahn
    Jong Hyo Kim
    European Radiology, 2022, 32 : 6407 - 6417