Objective and Subjective Image Quality of Liver Prechyma and Hepatic Metastass with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor

被引:53
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Meyer, Mathias [1 ]
Fink, Christian [3 ]
Hohenberger, Peter [4 ]
Leidecker, Christianne [5 ]
Schoenberg, Stefan O. [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[3] Gen Hosp Celle, Dept Radiol, Celle, Germany
[4] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Dept Surg,Div Surg Oncol & Thorac Surg, D-68167 Mannheim, Germany
[5] Siemens Healthcare Sect, Forchheim, Germany
关键词
Dual-source CT; dual-energy CT; gastrointestinal stromal tumor; hepatic metastasis; virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; CRITERIA; FUSION; RECIST; CHOI;
D O I
10.1016/j.acra.2014.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare in dual-energy CT (DECT) conventionally reconstructed polyenergetic images (PEI) at 120 kVp to virtual monoenergetic images (MEI) at different kiloelectron volt (key) levels for evaluation of liver and gastrointestinal stromal tumor (GIST) hepatic metastases with regard to objective (IQob) and subjective image quality (IQsub) assessed by two readers of varying experience. Image quality was correlated to patient size and compared between PEI and MEI. Materials and Methods: From 50 examinations of 17 GIST patients (12 with hepatic metastases) undergoing abdominal dual-source DECT for staging, therapy monitoring or follow-up, PEI and nine MEI in 10-keV intervals from 40 to 120 keV were reconstructed. Liver contrast-to-noise ratios (CNR) and metastasis-to-liver ratios were calculated. MEI reconstructions with the highest IQob were compared to PEI for IQsub by one experienced reader (ER) and one inexperienced reader (IR). Patients' diameters were correlated to IQob and IQsub ratings. Results: MEI at 70 keV had the highest IQob with equal liver CNR and metastasis-to-liver ratio compared to PEI. The ER rated 70-keV MEI and PEI equally high (median 4), whereas the IR rated IQsub best in 70-keV MEI (median 5). Unlike in PEI, IQsub ratings in 70-keV MEI were not correlated to patient size. Conclusions: MEI at 70 keV provided an IQob equivalent to PEI. Regarding the IR, IQsub was improved in 70-keV MEI compared to PEI and less dependent on patient size. Therefore, IRs might improve their diagnostic confidence in the assessment of hepatic GIST metastases by evaluating MEI reconstructions at 70 keV.
引用
收藏
页码:514 / 522
页数:9
相关论文
共 50 条
  • [1] Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    Yu, Lifeng
    Christner, Jodie A.
    Leng, Shuai
    Wang, Jia
    Fletcher, Joel G.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (12) : 6371 - 6379
  • [2] Dual-energy CT in patients with abdominal malignant lymphoma: impact of noise- optimised virtual monoenergetic imaging on objective and subjective image quality
    Lenga, L.
    Czwikla, R.
    Wichmann, J. L.
    Leithner, D.
    Albrecht, M. H.
    D'Angelo, T.
    Arendt, C. T.
    Booz, C.
    Hammerstingl, R.
    Vogl, T. J.
    Martin, S. S.
    CLINICAL RADIOLOGY, 2018, 73 (09) : 833.e19 - 833.e27
  • [3] Image Quality of Virtual Monochromatic Reconstructions of Noncontrast CT on a Dual-Source CT Scanner in Adult Patients
    van Ommen, Fasco
    Kauw, Frans
    Bennink, Edwin
    Heit, Jeremy J.
    Wolman, Dylan N.
    Dankbaar, Jan Willem
    de Jong, Hugo W. A. M.
    Wintermark, Max
    ACADEMIC RADIOLOGY, 2021, 28 (10) : E323 - E330
  • [4] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Long-Jiang Zhang
    Jin Peng
    Sheng-Yong Wu
    Z. Jane Wang
    Xin-Sheng Wu
    Chang-Sheng Zhou
    Xue-Man Ji
    Guang-Ming Lu
    European Radiology, 2010, 20 : 2257 - 2264
  • [5] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Zhang, Long-Jiang
    Peng, Jin
    Wu, Sheng-Yong
    Wang, Z. Jane
    Wu, Xin-Sheng
    Zhou, Chang-Sheng
    Ji, Xue-Man
    Lu, Guang-Ming
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2257 - 2264
  • [6] Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    Yu, Lifeng
    Primak, Andrew N.
    Liu, Xin
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (03) : 1019 - 1024
  • [7] Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT
    Kaltenbach, Benjamin
    Wichmann, Julian L.
    Pfeifer, Sophia
    Albrecht, Moritz H.
    Booz, Christian
    Lenga, Lukas
    Hammerstingl, Renate
    Dangelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 20 - 24
  • [8] Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT
    Andrea Agostini
    Alberto Mari
    Cecilia Lanza
    Nicolo’ Schicchi
    Alessandra Borgheresi
    Stefania Maggi
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 745 - 752
  • [9] Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT
    Agostini, Andrea
    Mari, Alberto
    Lanza, Cecilia
    Schicchi, Nicolo
    Borgheresi, Alessandra
    Maggi, Stefania
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (08): : 745 - 752
  • [10] Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT
    Remy-Jardin, Martine
    Guiffault, Lucas
    Oufriche, Idir
    Duhamel, Alain
    Flohr, Thomas
    Schmidt, Bernhard
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2024, 34 (12) : 7831 - 7844