Anomalies in the Prescribing of Soft Contact Lens Power

被引:2
|
作者
Young, Graeme [1 ]
Moody, Kurt [2 ]
Sulley, Anna [1 ]
机构
[1] Visioncare Res Ltd, Farnham GU9 7EN, Surrey, England
[2] Vis Care Inc, Vistakon, Jacksonville, FL USA
来源
关键词
Soft contact lenses; Power; Prescribing; ACCEPTANCE; ERRORS;
D O I
10.1097/ICL.0b013e3181909c20
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To determine the proportion of prescribed soft lenses rounded to the nearest half diopter and any variations from country to country and between lens types. Methods: Marketing data were obtained for soft lenses supplied during a I-year period for lenses representing each of the following categories: mid-water hydrogel (MWH), silicone hydrogel, daily disposable, and toric silicone hydrogel (TSH). The data were analyzed for several countries/regions. Spherical lenses were analyzed in the range 1.00 to 5.75 D for pills and minus powers, and toric lenses in the range 0.50 to 5.75 D. This ensured a similar number of lenses in full or half diopter powers were compared with quarter and three-quarter diopter powers, and that there was no enforced rounding due to nonavailability of powers. By comparing the proportion of lenses from the 2 power groups, the proportion of lenses rounded to the nearest half diopter was estimated. It was assumed that half the difference between the totals of the 2 power groups represented those lenses dispensed to die nearest half diopter and, therefore, dispensed inaccurately; this was termed the "rounding rate" (RR). Results: The power distribution curve for the sphere powers spiked in half diopter steps, illustrated a bias toward prescribing full and half diopter powers. With all lenses, the RR varied widely between countries. For the MWH, this ranged from 1.7% (Canada) to 11.6% (Iberia). The RRs were 2 to 3 times higher for plus than minus power lenses, however, this also varied by country. Overall, the RRs were lower for the silicone hydrogel and daily disposable contact lenses compared with the MWH, in particular for France and Iberia. The TSH results showed the greatest consistency between countries, with RRs ranging from 3.9% (Germany) to 9.5% (Rest of Europe). Most countries showed similar or lower RRs for TSH compared with MWH although, for sonic countries (e.g., United Kingdom, Nordic), these were higher. There was less difference in RRs for TSH lenses between plus and minus spheres. Conclusion: A surprising proportion of sell lenses are prescribed to the nearest half diopter, although this varies according to lens type. There are also considerable variations between countries, presumably due to differences in training, fitting practices, and supply routes. These findings suggest that there is widespread room for improvement in the prescribing accuracy of soft contact lenses.
引用
收藏
页码:11 / 14
页数:4
相关论文
共 50 条
  • [21] Simulation of the Effect of Material Properties on Soft Contact Lens On-Eye Power
    Moore, Joshua
    Lopes, Bernardo T.
    Eliasy, Ashkan
    Geraghty, Brendan
    Wu, Richard
    White, Lynn
    Elsheikh, Ahmed
    Abass, Ahmed
    BIOENGINEERING-BASEL, 2019, 6 (04):
  • [22] POWER AND RADIUS CHANGES INDUCED IN SOFT CONTACT-LENS SYSTEMS BY FLEXURE
    WEISSMAN, BA
    GARDNER, KM
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1984, 61 (04): : 239 - 245
  • [23] Comparison of soft contact lens comfort using three contact lens materials and four contact lens solutions
    Berntsen, David A.
    Hickson-Curran, Sheila B.
    Jones, Lyndon William
    Mathew, Jessica Horne
    Mirza, Aftab A.
    Morgan, Philip B.
    Schulze, Marc M.
    Nichols, Jason J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [24] Soft contact lens induced blepharoptosis
    Verhoekx, Jennifer S. N.
    Detiger, Sanne E.
    Muizebelt, Gerlof
    Wubbels, Rene J.
    Paridaens, Dion
    ACTA OPHTHALMOLOGICA, 2019, 97 (01) : E141 - E142
  • [25] SOFT CONTACT-LENS DEPOSITS
    STENSON, S
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 257 (20): : 2823 - 2823
  • [26] The conformity of a soft contact lens on the eye
    Funkenbusch, GMT
    Benson, RC
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 341 - 348
  • [27] Soft contact lens polymers: an evolution
    Nicolson, PC
    Vogt, J
    BIOMATERIALS, 2001, 22 (24) : 3273 - 3283
  • [28] The conformity of a soft contact lens on the eye
    Mechanics of Flexible Struct. Proj., Department of Mechanical Engineering, University of Rochester, Rochester, NY 14627, United States
    不详
    J. BIOMECH. ENG., 3 (341-348):
  • [29] METHOD OF SOFT CONTACT LENS MEASUREMENT
    NAKAJIMA, A
    SHIBATA, H
    MAGATANI, H
    HIRANO, A
    FOLIA OPHTHALMOLOGICA JAPONICA, 1974, 25 (09): : 123 - 131
  • [30] Contact lens prescribing pattern in India-2011
    Thite, Nilesh
    Noushad, Babu
    Kunjeer, Gauri
    CONTACT LENS & ANTERIOR EYE, 2013, 36 (04): : 182 - 185