Fatigue performance of distributed optical fiber sensors in reinforced concrete elements

被引:26
|
作者
Barrias, Antonio [1 ]
Casas, Joan R. [1 ]
Villalba, Sergi [2 ]
机构
[1] Tech Univ Catalonia, UPC BarcelonaTech, Dept Civil & Environm Engn, C Jordi Girona 1-3, Barcelona 08034, Spain
[2] Tech Univ Catalonia, Dept Project & Construct Engn, UPC BarcelonaTech, C Colom 11, Terrassa 08222, Spain
关键词
Distributed optical fiber sensors; Rayleigh backscatter; Structural health monitoring; Sensor bonding; Fatigue; Cycle-loading; STRAIN-MEASUREMENT;
D O I
10.1016/j.conbuildmat.2019.05.072
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the authors present the results of a laboratory test where two reinforced concrete beams were instrumented with Distributed Optical Fiber Sensors (DOFS) to allow the monitoring g of strain in four different longitudinal segments bonded to their bottom surface. The test objective was to confirm the ability and good performance of the DOFS to monitor bridge structures in a long-term basis. To this end, the two specimens were submitted to a fatigue test up to 2 million load cycles. The amplitude of the stress range applied during the fatigue test was representative of what is expected on a standard highway bridge under vehicular traffic. Additionally, each of the four DOFS segments was bonded using a different adhesive to also investigate on the fatigue performance of the adhesive agents normally used. Finally, the collected data is checked against the data recorded with strain gauges also deployed on the beam specimens. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:214 / 223
页数:10
相关论文
共 50 条
  • [31] Fatigue behavior of steel fiber reinforced concrete
    Nanni, Antonio, 1600, (13):
  • [32] Distributed Optical Fiber Sensors and Their Applications
    Adachi, Shoji
    2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 300 - 304
  • [33] DISTRIBUTED OPTICAL-FIBER SENSORS
    ROGERS, AJ
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1986, 19 (12) : 2237 - 2255
  • [34] Distributed optical fiber pressure sensors
    Schenato, Luca
    Galtarossa, Andrea
    Pasuto, Alessandro
    Palmieri, Luca
    OPTICAL FIBER TECHNOLOGY, 2020, 58
  • [35] Flexural fatigue behavior of ultra-high performance fiber reinforced concrete
    Deng, Pengru
    Kuwagaki, Junya
    Matsumoto, Takashi
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 444
  • [36] Fatigue Performance Test and Life Calculation of Fiber-Reinforced Asphalt Concrete
    Meng, Fenglin
    Gao, Danying
    Chen, Faqi
    Huang, Chunshui
    ANNALES DE CHIMIE-SCIENCE DES MATERIAUX, 2020, 44 (02): : 133 - 139
  • [37] Static and fatigue performance of stud shear connector in steel fiber reinforced concrete
    Xu, Chen
    Su, Qingtian
    Masuya, Hiroshi
    STEEL AND COMPOSITE STRUCTURES, 2017, 24 (04): : 467 - 479
  • [38] Experimental study on direct tensile fatigue performance of basalt fiber reinforced concrete
    Xutao Zhang
    Chao Lou
    Xikuan Lyu
    Scientific Reports, 14
  • [39] Experimental study on direct tensile fatigue performance of basalt fiber reinforced concrete
    Zhang, Xutao
    Lou, Chao
    Lyu, Xikuan
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [40] Thermal fatigue performance of steel fiber reinforced polymer high strength concrete
    Wang Haiyang
    Huang Peiyan
    Zheng Xiaohong
    Guo Xinyan
    ADVANCED BUILDING MATERIALS AND SUSTAINABLE ARCHITECTURE, PTS 1-4, 2012, 174-177 : 1060 - 1066