Cross-calibration of ionization chambers in proton and carbon beams

被引:34
|
作者
Kanai, T
Fukumura, A
Kusano, Y
Shimbo, M
Nishio, T
机构
[1] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
[2] Accelerator Engn Corp, Inage Ku, Chiba 2630043, Japan
[3] East Hosp, Natl Canc Ctr, Kashiwa, Chiba 2778577, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 05期
关键词
D O I
10.1088/0031-9155/49/5/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The calibration coefficients of a parallel plate ionization chamber are examined by comparing the coefficients obtained through three methods: a calculation from a Co-60 calibration coefficient, N-D,N-W,N-60Co, a cross-calibration of a parallel plate ionization chamber using a cylindrical ionization chamber at the plateau region of a mono-energetic beam and a cross-calibration of the chamber using a cylindrical chamber at the middle of the SOBP of the therapeutic beams. This paper also examines reference conditions for determining absorbed dose to water in the cases of therapeutic carbon and proton beams. In the dose calibration procedure recommended by IAEA, irradiation fields should be larger than 10 cm in diameter and the water phantom should extend by at least 5 cm beyond each side of the field. These recommendations are experimentally verified for proton and carbon beams. For proton beams, the calibration coefficients obtained by these three methods approximately agreed. For carbon beams, the calibration coefficients obtained by the second method were about 1.0% larger than those obtained by the third method, and the calibration coefficients obtained by cross-calibration using 290 MeV/u beams were 0.5% lower than those obtained using 400 MeV/u beams. The calibration coefficient obtained by the first method agreed roughly with the results obtained by SOBP beams.
引用
收藏
页码:771 / 781
页数:11
相关论文
共 50 条
  • [41] Uncertainty analysis in cross-calibration and optimization calculation of calibration coefficients
    Gao Shuai
    Li Yuan
    Bai Ting-zhu
    Zhang Yu-xiang
    Zheng Xiao-bing
    CHINESE OPTICS, 2020, 13 (03): : 568 - 576
  • [42] Aspects of the Cross-Calibration Method in Laser Goniometry
    P. A. Pavlov
    Measurement Techniques, 2015, 58 : 970 - 974
  • [43] OCO/GOSAT Preflight Cross-Calibration Experiment
    Sakuma, Fumihiro
    Bruegge, Carol J.
    Rider, David
    Brown, David
    Geier, Sven
    Kawakami, Shuji
    Kuze, Akihiko
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2010, 48 (01): : 585 - 599
  • [44] Cross-Calibration of Hinode/EIS and SDO/AIA
    O'Dwyer, B.
    Del Zanna, G.
    Mason, H. E.
    Weber, M. A.
    Tripathi, D.
    4TH HINODE SCIENCE MEETING: UNSOLVED PROBLEMS AND RECENT INSIGHTS, 2012, 455 : 369 - +
  • [45] Aspects of the Cross-Calibration Method in Laser Goniometry
    Pavlov, P. A.
    MEASUREMENT TECHNIQUES, 2015, 58 (09) : 970 - 974
  • [46] Perturbation factors for cylindrical ionization chambers in proton beams. Part I: corrections for gradients
    Palmans, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14): : 3483 - 3501
  • [47] Investigating the Effective Point of Measurement for Plane-Parallel Ionization Chambers in Clinical Proton Beams
    Baumann, K. S.
    Lourenco, A.
    Wulff, J.
    Vilches-Freixas, G.
    Palmans, H.
    MEDICAL PHYSICS, 2024, 51 (10) : 7685 - 7686
  • [48] Experimental determination of k Q factors for two types of ionization chambers in scanned proton beams
    Medin, Joakim
    Andreo, Pedro
    Palmans, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (05):
  • [49] Radiometric cross-calibration of Terra ASTER and MODIS
    Yuan, Karen
    Thome, Kurt
    McCorkel, Joel
    EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [50] CROSS-CALIBRATION OF DXA SCANNERS FOR SPINE MEASUREMENTS
    TOTHILL, P