A Novel Technique of Rescuing Capsulorhexis Radial Tear-out using a Cystotome

被引:1
|
作者
Karim, Shah M. R. [1 ]
Ong, Chin T. [2 ]
Miah, Mizanur R.
Sleep, Tamsin [3 ]
Hanifudin, Abdul [1 ]
机构
[1] NHS Lanarkshire, Dept Ophthalmol, Hairmyres Hosp, E Kilbride, Lanark, Scotland
[2] Royal Devon & Exeter NHS Fdn Trust, Dept Ophthalmol, Exeter, Devon, England
[3] South Devon Healthcare NHS Trust, Dept Ophthalmol, Torquay, Devon, England
来源
关键词
Medicine; Issue; 47; Phacoemulsification surgery; cataract surgery; capsulorhexis; capsulotomy; technique; Continuous curvilinear capsulorhexis; cystotome; capsulorhexis radial tear; capulorhexis COMPLICATION;
D O I
10.3791/2317
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Part 1 : Purpose: To demonstrate a capsulorhexis radial tear out rescue technique using a cystotome on a virtual reality cataract surgery simulator and in a human eye. Part 2 : Method: Steps: When a capsulorhexis begins to veer radially towards the periphery beyond the pupillary margin the following steps should be applied without delay. 2.1) Stop further capsulorhexis manoeuvre and reassess the situation. 2.2) Fill the anterior chamber with ophthalmic viscosurgical device (OVD). We recommend mounting the cystotome to a syringe containing OVD so that the anterior chamber can be reinflated rapidly. 2.3) The capsulorhexis flap is then left unfolded on the lens surface. 2.4) The cystotome tip is tilted horizontally to avoid cutting or puncturing the flap and is engaged on the flap near the leading edge of the tear but not too close to the point of tear. 2.5) Gently push or pull the leading edge of tear opposite to the direction of tear. 2.6) The leading tearing edge will start to do a 'U-Turn'. Maintain the tension on the flap until the tearing edge returns to the desired trajectory. Part 3 : Results: Using our technique, a surgeon can respond instantly to radial tear out without having to change surgical instruments. Changing surgical instruments at this critical stage runs a risk of further radial tear due to sudden shallowing of anterior chamber as a result of forward pressure from the vitreous. Our technique also has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse. Part 4 : Discussion The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis tear-out techniques. Capsulorhexis is the most important and complex part of phacoemulsification and endocapsular intraocular lens implantation procedure. A successful cataract surgery depends on achieving a good capsulorhexis. During capsulorhexis, surgeons may face a challenging situation like a capsulorhexis radial tear-out. A surgeon must learn to tackle the problem promptly without making the situation worse. Some other methods of rescuing the situation have been described using a capsulorhexis forceps. However, we believe our method is quicker, more effective and easier to manipulate as demonstrated on the EYESi surgical simulator and on a human eye. Acknowledgments: List acknowledgements and funding sources. We would like to thank Dr. Wael El Gendy, for video clip. Disclosures: describe potential conflicting interests or state We have nothing to disclose. References: 1. Brian C. Little, Jennifer H. Smith, Mark Packer. J Cataract Refract Surg 2006; 32: 1420 1422, Issue-9. 2. Neuhann T. Theorie und Operationstechnik der Kapsulorhexis. Klin Monatsbl Augenheilkd. 1987; 1990: 542-545. 3. Gimbel HV, Neuhann T. Development, advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990; 16: 31-37. 4. Gimbel HV, Neuhann T. Continuous curvilinear capsulorhexis. (letter) J Cataract Refract Sur. 1991; 17: 110-111.
引用
收藏
页数:2
相关论文
共 33 条
  • [21] A new technique for sphincter-preserving anal fistula repair using a novel radial emitting laser probe
    Wilhelm, A.
    TECHNIQUES IN COLOPROCTOLOGY, 2011, 15 (04) : 445 - 449
  • [22] HUMAN TEAR FILM PRE-RUPTURE PHASE TIME (TP-RPT) - A NON-INVASIVE TECHNIQUE FOR EVALUATING THE PRE-CORNEAL TEAR FILM USING A NOVEL KERATOMETER MIRE
    HIRJI, N
    PATEL, S
    CALLANDER, M
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1989, 9 (02) : 139 - 142
  • [23] A Novel Radial Flux Sensing Technique for Stator Turn Fault Detection in Induction Motors in Online Mode Using Observer Coil
    Surya, G. N.
    Khan, Z. J.
    Ballal, M. S.
    2015 INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2015, : 93 - 98
  • [24] Predicting Daily Streamflow in a Cold Climate Using a Novel Data Mining Technique: Radial M5 Model Tree
    Kisi, Ozgur
    Heddam, Salim
    Keshtegar, Behrooz
    Piri, Jamshid
    Adnan, Rana Muhammad
    WATER, 2022, 14 (09)
  • [25] Biomechanical Comparison of Inside-Out and All-Inside Meniscal Repair in Controlling the Peripheral Gap and Extrusion of the Lateral Meniscus With a Complete Radial Tear: A Cadaveric Study Using a Robotic Simulator
    Shiwaku, Kousuke
    Otsubo, Hidenori
    Takahashi, Katsunori
    Suzuki, Daisuke
    Yamakawa, Satoshi
    Kamiya, Tomoaki
    Suzuki, Tomoyuki
    Okada, Yohei
    Okimura, Shinichiro
    Watanabe, Kota
    Fujie, Hiromichi
    Teramoto, Atsushi
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2025, 13 (03)
  • [26] Optimal analysis of time varying load radial distribution system with photovoltaic and wind generating system using novel hybrid optimization technique
    Vempalle, Rafi
    Dhal, P. K.
    RENEWABLE ENERGY FOCUS, 2022, 41 : 246 - 257
  • [27] A Novel Chip Placement Technlogy for Fan-Out WLP using Self-Assembly Technique with Porous Chuck Table
    Yamada, Tadatomo
    Takano, Ken
    Menjo, Toshiaki
    Takyu, Shinya
    IEEE 71ST ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC 2021), 2021, : 1088 - 1094
  • [28] A novel technique to restore access in patients with central venous occlusion using the Surfacer(R) Inside-Out(R) Access Catheter System
    Baetens, Tarik R.
    Rotmans, Joris, I
    van der Meer, Rutger W.
    van Rijswijk, Carla S. P.
    JOURNAL OF VASCULAR ACCESS, 2020, 21 (05): : 778 - 782
  • [29] Prospective Randomized Study Comparing Incidence Of Doppler Signal Flow Detected Radial Artery Occlusion Post-transradial Percutaneous Coronary Intervention Between Safeguard Radial Versus Tr Band Radial Compression Devices Using A Novel Air-inflation Technique
    Voon, Victor
    Ul Haq, Muhammad Ayyaz
    Cahill, Ciara
    Mannix, Kirsten
    Ahern, Catriona
    Hennessy, Terry
    Arnous, Samer
    Kiernan, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (03) : S24 - S24
  • [30] A Novel Technique to Convert Static Sling into a Dynamic Sling in Reconstruction of Total Lower Lip Defects Using Palmaris Longus Tendon with Free Radial Forearm Flap and Case Series
    Jaganathan, Balaji K.
    Kumar, Sashi Bhushan
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 75 (03) : 1981 - 1985