Prospective evaluation of regional oxygen saturation to estimate central venous saturation in sepsis

被引:10
|
作者
Koch, Christian [1 ]
Roehrig, Rainer [1 ]
Monz, Tobias [1 ]
Hecker, Andreas [2 ]
Uhle, Florian [3 ]
Schneck, Emanuel [1 ]
Weigand, Markus A. [1 ,3 ]
Lichtenstern, Christoph [1 ,3 ]
机构
[1] Univ Hosp Giessen & Marburg, Dept Anesthesiol & Intens Care Med, D-35392 Giessen, Germany
[2] Univ Hosp Giessen & Marburg, Dept Gen & Thorac Surg, D-35392 Giessen, Germany
[3] Univ Heidelberg Hosp, Dept Anesthesio, D-69120 Heidelberg, Germany
关键词
Sepsis; Spectroscopy; Near infrared; Lactic acid; Central venous saturation; Oxygen consumption; Outcome assessment; NEAR-INFRARED SPECTROSCOPY; BLOOD LACTATE LEVELS; SEPTIC SHOCK; TISSUE OXYGENATION; ORGAN DYSFUNCTION; PROGNOSTIC VALUE; RISK-FACTORS; SURGERY; NIRS; ASSOCIATION;
D O I
10.1007/s10877-015-9683-x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Current treatment guidelines for sepsis claim an early goal-directed hemodynamic optimization including fluid resuscitation, use of vasopressors and inotropic agents. We investigated the correlation between the prominent treatment goal central venous saturation (ScvO(2)) and the frontal and the thenar regional oxygen saturation (rSO(2)) measured by near infrared spectroscopy. Secondary, we examined the value of ScvO(2), lactate levels and rSO(2) as surrogate markers of an impaired tissue oxygenation for outcome prediction in sepsis. This prospective, observational study was performed at the surgical intensive care unit of the University Hospital Giessen. A total of 50 patients with sepsis, severe sepsis or septic shock were included. ScvO(2), rSO(2) and lactate were measured at sepsis diagnosis (baseline), 24 and 48 h, thereafter. We investigated the predictive value of frontal and thenar rSO(2) for a decreased SvcO(2) under 70 %. For survivor and non-survivors ScvO(2), rSO(2) and lactate were analysed. Patients with ScvO(2) > 70 % showed a trend to higher levels of fontal rSO(2) (62.81 +/- A 8.06 vs. 53.54 +/- A 15.48; p = 0.058). ROC-analysis revealed a minor prediction of a decreased ScvO(2) by frontal rSO(2) levels at baseline (AUC = 0.687; 95 % CI 0.511-0.863; p = 0.047). Combined measurements of lactate and ScvO2 showed significantly elevated mortality for patients with ScvO2 a parts per thousand yen70 % and lactate levels a parts per thousand yen2.5 mmol/l (log rank test p = 0.004). In the group with ScvO(2) < 70 % and lactate levels < 2.5 mmol/l no patients died during the observation period. Frontal rSO(2) correlates with ScvO(2) but both frontal and thenar rSO2 do not exactly discriminate between patients with high or low ScvO2 in sepsis. The combination of elevated lactate > 2.5 mmol/l and ScvO(2) > 70 % is highly associated with poor outcome in ICU patients with sepsis, severe sepsis and septic shock.
引用
收藏
页码:443 / 453
页数:11
相关论文
共 50 条
  • [41] Skeletal muscle oxygen saturation does not estimate mixed venous oxygen saturation in patients with severe left heart failure and additional severe sepsis or septic shock
    Matej Podbregar
    Hugon Možina
    Critical Care, 11
  • [42] MONITORING OF CENTRAL VENOUS OXYGEN-SATURATION VERSUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    MARTIN, C
    AUFFRAY, JP
    BADETTI, C
    PERRIN, G
    PAPAZIAN, L
    GOUIN, F
    INTENSIVE CARE MEDICINE, 1992, 18 (02) : 101 - 104
  • [43] Comparison of mixed venous oxygen saturation and central venous oxygen saturation in patients undergoing living donor liver transplantation
    Ri, H. -S
    Jeon, S.
    Yoon, J. -U
    TRANSPLANTATION, 2018, 102 : 202 - 202
  • [44] Skeletal muscle oxygen saturation does not estimate mixed venous oxygen saturation in patients with severe left heart failure and additional severe sepsis or septic shock
    Podbregar, Matej
    Mozina, Hugon
    CRITICAL CARE, 2007, 11 (01)
  • [45] Continuous monitoring of the central venous oxygen saturation in surgical patients: Comparison to the monitoring of the mixed venous saturation
    Cohendy, R
    Peries, C
    Lefrant, JY
    Doucot, PY
    Saissi, G
    Eledjam, JJ
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (08) : 956 - 956
  • [46] Central Venous Oxygen Saturation Cannot Replace Mixed Venous Saturation in Patients Undergoing Cardiac Surgery
    Lorentzen, Anne-Grethe
    Lindskov, Christian
    Sloth, Erik
    Jakobsen, Carl-Johan
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (06) : 853 - 857
  • [47] RELATIONSHIP BETWEEN CENTRAL AND PERIPHERAL VENOUS OXYGEN SATURATION AND LACTATE LEVELS: A PROSPECTIVE STUDY
    Goyal, Nikhil
    Taylor, Andrew R.
    Rivers, Emanuel P.
    JOURNAL OF EMERGENCY MEDICINE, 2016, 50 (06): : 809 - 817
  • [48] Accuracy of central venous oxygen saturation with a fiberoptic catheter
    D Chiumello
    V Berto
    C Mietto
    M Botticelli
    M Chierichetti
    F Tallarini
    Critical Care, 13 (Suppl 1):
  • [49] Abnormal central venous oxygen saturation in cardiac surgery patients: a prospective, observational study
    D Unic-Stojanovic
    P Vukovic
    D Nezic
    M Filipovic
    P Milojevic
    M Jovic
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [50] CENTRAL VENOUS OXYGEN SATURATION IN SHOCK - STUDY IN MAN
    LEE, J
    BARBER, R
    WRIGHT, F
    STANLEY, L
    ANESTHESIOLOGY, 1972, 36 (05) : 472 - &