Automated high performance liquid chromatography with on-line reduction of disulfides and chemiluminescence detection for determination of thiols and disulfides in biological fluids

被引:22
|
作者
Bai, Shouli [1 ]
Chen, Qingshuo [1 ]
Lu, Chao [1 ]
Lin, Jin-Ming [2 ]
机构
[1] Beijing Univ Chem Technol, State Key Lab Chem Resource Engn, Beijing 100029, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
On-line reduction; Thiols; Disulfides; Chemiluminescence; High performance liquid chromatography; OXIDATIVE STRESS; GOLD NANOPARTICLES; GLUTATHIONE; ASSAY; TRIS(2-CARBOXYETHYL)PHOSPHINE; AMINOTHIOLS; CLEAVAGE; BONDS;
D O I
10.1016/j.aca.2013.01.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In general, the reduction of disulfide bonds with tris(2-carboxyethyl)phosphine (TCEP) is performed using off-line operation, which is not only time-consuming but also vulnerable to the spontaneous reoxidation of thiols during sample preparation and subsequent analysis procedures. To the best of our knowledge, there has been not any case on the on-line reduction for biological disulfides coupled with high performance liquid chromatography (HPLC). In this study, these obstacles are overcome by packing Zn(II)-TCEP complexes into a home-made column. The as-synthesized Zn(II)-TCEP complexes enable efficient reduction of disulfide bonds at pH 3.0. This acidic pH value was compatible with that of the mobile phase for HPLC separation of thiols and disulfides. Therefore, using fluorosurfactant-prepared triangular gold nanoparticles as HPLC postcolumn specific chemiluminescence (CL) reagents for thiols, the feasibility of the established on-line reduction column has been confirmed for the direct identification of both thiols and disulfides by incorporating this reduction column into a single chromatographic separation. Detection limits for these analytes range from 8.3 to 25.4 nM and the linear range in a log log plot can comprise three orders of magnitude. Finally, the utility of this automated on-line reduction of disulfides-HPLC-CL system has been demonstrated for the reliable determination of thiols and disulfides in human urine and plasma samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [21] Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection
    Ahmed, Sameh
    Fujii, Shuu
    Kishikawa, Naoya
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) : 76 - 82
  • [22] DETERMINATION OF MORPHINE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION
    ABBOTT, RW
    TOWNSHEND, A
    GILL, R
    ANALYST, 1987, 112 (04) : 397 - 406
  • [23] Direct Determination of Redox Statuses in Biological Thiols and Disulfides with Noncovalent Interactions of Poly(ionic liquid)s
    Zhang, Wanlin
    Li, Yao
    Liang, Yun
    Yin, Xianpeng
    Liu, Chengcheng
    Wang, Shigiang
    Tian, Li
    Dong, Hao
    Li, Guangtao
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (33) : 30137 - 30145
  • [24] DETERMINATION OF CAPTOPRIL AND ITS MIXED DISULFIDES IN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HAYASHI, K
    MIYAMOTO, M
    SEKINE, Y
    JOURNAL OF CHROMATOGRAPHY, 1985, 338 (01): : 161 - 169
  • [25] Determination of polyamines by high-performance liquid chromatography with chemiluminescence detection
    Wu, Qiuhua
    Su, Yuqin
    Yang, Lihua
    Li, Jingci
    Ma, Jingjun
    Wang, Chun
    Li, Zhengping
    MICROCHIMICA ACTA, 2007, 159 (3-4) : 319 - 324
  • [26] Determination of polyamines by high-performance liquid chromatography with chemiluminescence detection
    Qiuhua Wu
    Yuqin Su
    Lihua Yang
    Jingci Li
    Jingjun Ma
    Chun Wang
    Zhengping Li
    Microchimica Acta, 2007, 159 : 319 - 324
  • [27] On-line screening method for antioxidants by liquid chromatography with chemiluminescence detection
    Ogawa, A
    Arai, H
    Tanizawa, H
    Miyahara, T
    Toyo'oka, T
    ANALYTICA CHIMICA ACTA, 1999, 383 (03) : 221 - 230
  • [28] Microdialysis sampling and high-performance liquid chromatography with chemiluminescence detection for in-vivo on-line determination and study of the pharmacokinetics of levodopa in blood
    Chen, FN
    Zhang, ZJ
    Zhang, YX
    He, DY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (01) : 211 - 215
  • [29] Microdialysis sampling and high-performance liquid chromatography with chemiluminescence detection for in-vivo on-line determination and study of the pharmacokinetics of levodopa in blood
    Chen Funan
    Zhang Zhujun
    Zhang Yingxue
    He Deyong
    Analytical and Bioanalytical Chemistry, 2005, 382 : 211 - 215
  • [30] DETERMINATION OF HOMOCYSTEINE, PENICILLAMINE, AND THEIR SYMMETRICAL AND MIXED DISULFIDES BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    RABENSTEIN, DL
    YAMASHITA, GT
    ANALYTICAL BIOCHEMISTRY, 1989, 180 (02) : 259 - 263