Biosensor for detection of nanobacteria in water

被引:28
|
作者
Sommer, AP [1 ]
Gheorghiu, E
Cehreli, M
Mester, AR
Whelan, HT
机构
[1] Univ Ulm, Cent Inst Biomed Engn, D-89081 Ulm, Germany
[2] Natl Inst Pharmaceut Chem R&D, Bucharest 031299, Romania
[3] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[4] Semmelweis Univ, Fac Med, Dept Diagnost Radiol & Oncotherapy, H-1082 Budapest, Hungary
[5] Med Coll Wisconsin, Dept Neurol, Milwaukee, WI 53226 USA
关键词
D O I
10.1021/cg050418e
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The presence of nanobacteria in the environment follows from their abundance in humans, apparent abundance in the terrestrial atmosphere and agricultural irrigation with insufficiently treated water containing human excreta. Survivability of nanobacteria and increasing evidence for their implication in disease demand for their detection in environmental samples. Unfortunately, the 60-300 nm nanocrystalline biohazards resemble "harmless" aerosols that are common in the lower atmosphere and water reservoirs. Here we propose a detector for discrimination between biocolloids and nonbiogenic objects of the same size. It exploits deviations from ideal deposition patterns, formed by drops of nanosuspensions evaporating on substrates. Variations in the crystallinity and/or shape of ring patterns, due to differences in the adhesive capacity of nanoparticles contained in the drops, provide principles to design simple and sensitive biosensors, responding to otherwise nondetectable contaminations of both drops and substrates. Patterns can be visualized on mirror-polished optically reflective substrates by a light microscope operating in the reflection mode. For instance, perfect ring structures emerged from water drops which contained polystyrene nanospheres, and uniformly dense deposition patterns formed from those containing hydroxyapatite nanoparticles. The principal difference is due to the interplay between the convective flow, driving suspended material to the periphery of the evaporating drop, and attraction between nanoparticles and substrate, immobilizing them upon contact. Protected by an outer shell of apatite, nanobacteria are predicted to behave completely different from polystyrene (and most other nanospheres): in water drops with contact angles 0 <= alpha <= 90 degrees those landing around the center of the area wetted by the drop will tend to remain fixed, instead of being moved by the convective flow. The biosensor could allow the identification of nanobacteria in precipitation, water reservoirs, or filtered soil, by facilitating their localization on substrates by high-resolution imaging techniques, which are applied complementary to analytical, spectroscopic, and culture methods.
引用
收藏
页码:492 / 497
页数:6
相关论文
共 50 条
  • [41] A biosensor platform for rapid detection of E. coli in drinking water
    Hesari, Nikou
    Alum, Absar
    Elzein, Mohamad
    Abbaszadegan, Morteza
    ENZYME AND MICROBIAL TECHNOLOGY, 2016, 83 : 22 - 28
  • [42] Rapid detection of norfloxacin in water by evanescent wave fiber optic biosensor
    Zhuo, Yu-Xin
    Xu, Wen-Juan
    Cheng, Yuan
    Song, Dan
    Han, Xiang-Zhi
    Long, Feng
    Zhongguo Huanjing Kexue/China Environmental Science, 2022, 42 (05): : 2283 - 2288
  • [43] DETECTION OF TNT IN WATER USING AN EVANESCENT-WAVE FIBEROPTIC BIOSENSOR
    SHRIVERLAKE, LC
    BRESLIN, KA
    CHARLES, PT
    CONRAD, DW
    GOLDEN, JP
    LIGLER, FS
    ANALYTICAL CHEMISTRY, 1995, 67 (14) : 2431 - 2435
  • [44] Nanoporous impedemetric biosensor for detection of trace atrazine from water samples
    Pichetsumthorn, Pie
    Vattipalli, Krishna
    Prasad, Shalini
    BIOSENSORS & BIOELECTRONICS, 2012, 32 (01): : 155 - 162
  • [45] Impedimetric paper-based biosensor for the detection of bacterial contamination in water
    Rengaraj, Saravanan
    Cruz-Izquierdo, Alvaro
    Scott, Janet L.
    Di Lorenzo, Mirella
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 50 - 58
  • [46] Detection of environmental pollutant cadmium in water using a visual bacterial biosensor
    Hui, Chang-ye
    Guo, Yan
    Li, Han
    Gao, Chao-xian
    Yi, Juan
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [47] An automated, robotic biosensor for the electrochemical detection of E. coli in water
    Kellner, Karlheinz
    Ettenauer, Joerg
    Zuser, Karen
    Posnicek, Thomas
    Brandl, Martin
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 594 - 597
  • [48] Direct detection of organophosphate pesticides in water by a fluorescence-based biosensor
    Barbieri, M. V.
    Rodrigues, A. C. M.
    Manco, G.
    Febbraio, F.
    TOXICOLOGY LETTERS, 2021, 350 : S90 - S90
  • [49] RNA biosensor for the rapid detection of viable Escherichia coli in drinking water
    Baeumner, AJ
    Cohen, RN
    Miksic, V
    Min, JH
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (04): : 405 - 413
  • [50] Nanotechnology-based Biosensor for the Detection of Harmful Pathogens in Potable Water
    Petronella, Francesca
    De Angelis, Melissa
    DeBiase, Daniela
    Lim, Seok-Im
    Jeong, Kwang-Un
    Godman, Nicholas
    Evans, Dean
    Mcconney, Michael
    De Sio, Luciano
    2021 IEEE 8TH INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (IEEE METROAEROSPACE), 2021, : 469 - 472