Flame atomic absorption determination of lead through on-line preconcentration by surfactant mediated glass wool retention

被引:4
|
作者
Katsaounos, CZ [1 ]
Paleologos, EK [1 ]
Karayannis, MI [1 ]
机构
[1] Univ Ioannina, Dept Chem, GR-45110 Ioannina, Greece
关键词
controlled pore glass-glass-wool-packed minicolumn; High-surface-area substrate; determination of lead; on-line surfactant mediated preconcentration; atomic absorption spectrometry;
D O I
10.1080/03067310500247561
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the fabrication of a mini column packed with controlled pore glass and glass wool, and its application for the on-line preconcentration of lead with the aid of an anionic surfactant ( sodium dodecyl sulphate, SDS) and AAS detection. Lead reacts with SDS in a highionic-strength environment, and the product is retained and preconcentrated on a high-surface area substrate like glass wool. The intervention of controlled pore glass increases the active surface of glasswool and prevents its accumulation into a sticky mass after wetting. Washing the mini column with a methanolic solution of HNO3, causes the retained micellar face to be eluted, and consequently the lead content can be determined with AAS. A preconcentration factor of 50 along with a signal enhancement due to the combined presence of SDS and methanol yields a detection limit of 1.5 mu g L-1. The correlation coefficient of the calibration curve is 0.999, and the linear range 5-500 mu g L-1. The method was used for the determination of lead in water and wastewater with good results.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 50 条