The paper considers technical and economic possibilities to provide geothermal heat to individual recipients using a mobile thermal storage system (M-TES) in Polish conditions. The heat availability, temperature and heat cost influence the choice of location-Banska Ni(z) over dotna, near Zakopane in the southern part of the Poland. The indirect contact energy storage container was selected with phase change material characterized by a melting temperature of 70 degrees C and a heat storage capacity of 250 kJ/kg, in the amount of 800 kg. The economic profitability of the M-TES system (with a price per warehouse of 6000 EUR, i.e., a total of 12,000 EUR-two containers are needed) can be achieved for a heat demand of 5000 kWh/year with the price of a replaced heat source at the level of 0.21 EUR/kWh and a distance between the charging station and building (heat recipient) of 0.5 km. For the heat demand of 15,000 kWh/year, the price for the replaced heat reached EUR 0.11/kWh, and the same distance. In turn, for a demand of 25,000 kWh/year, the price of the replaced heat source reached 0.085 EUR/kWh. The distance significantly affected the economic profitability of the M-TES system-for the analyzed case, a distance around 3-4 km from the heat source should be considered.