Current drug eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug delivery. A novel, absorbable-coating sirolimus-eluting stent (AC-SES) was evaluated for its capacity to deliver drug more evenly within the intimal area rather than concentrating drug around the stent struts and for its ability to match coating erosion with drug release. The coating consisted of absorbable poly-lactide-co-glycolic acid (PLGA) and crystalline sirolimus deposited by a dry-powder electrostatic process. The AC-SES demonstrated enhanced drug stability under simulated use conditions and consistent drug delivery balanced with coating erosion in a porcine coronary implant model. The initial drug burst was eliminated and drug release was sustained after implantation. The coating was absorbed within 90 days. Following implantation into porcine coronary arteries the AC-SES coating is distributed in the surrounding intimal tissue over the course of several weeks. Computational modeling of drug delivery characteristics demonstrates how distributed coating optimizes the load of drug immediately around each stent strut and extends drug delivery between stent struts. The result was a highly efficient arterial uptake of drug with superior performance to a clinical bare metal stent (BMS). Neointimal thickness (0.17+/-0.07 mm vs. 0.28+/-0.11 mm) and area percent stenosis (22+/-9% vs. 35+/-12%) were significantly reduced (p<0.05) by the AC-SES compared to the BMS 30 days after stent implantation in an overlap configuration in porcine coronary arteries. Inflammation was significantly reduced in the AC-SES compared to the BMS at both 30 and 90 days after implantation. Biocompatible, rapidly absorbable stent coatings enable the matching of drug release with coating erosion and provide for the controlled migration of coating material into tissue to reduce vicissitudes in drug tissue levels, optimizing efficacy and reducing potential toxicity. (C) 2012 Elsevier B. V. All rights reserved.
引用
收藏
页码:561 / 567
页数:7
相关论文
共 50 条
  • [31] Polymer coated mesoporous silica nanoparticles controlled by nanovalves for drug delivery
    Dong, Juyao
    Xue, Min
    Zink, Jeffrey I.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [32] Polymer-Coated Radioluminescent Nanoparticles for Quantitative Imaging of Drug Delivery
    Moore, Thomas L.
    Wang, Fenglin
    Chen, Hongyu
    Grimes, Stuart W.
    Anker, Jeffrey N.
    Alexis, Frank
    ADVANCED FUNCTIONAL MATERIALS, 2014, 24 (37) : 5815 - 5823
  • [33] Drug eluting coatings for paclitaxel delivery from coronary stents
    Richard, RE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U4316 - U4317
  • [34] DRUG DELIVERY FROM POLYMER MODIFIED ELECTRODES
    MILLER, LL
    ZINGER, B
    BLANKESPOOR, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 60 - COLL
  • [35] Biodegradable polymer drug eluting stents versus durable polymer drug eluting stents for percutaneous coronary intervention
    Kheifets, M.
    Levi, A.
    Bental, T.
    Perl, L.
    Codner, P.
    Wittberg, G.
    Talmor-Barkan, Y.
    Landes, U.
    Samara, A.
    Greenberg, G.
    Erez, A.
    Vaknin-Assa, H.
    Kornowski, R.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2137 - 2137
  • [36] Drug delivery to the vessel wall with drug coated balloons
    Slager, Joram
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [37] Porous polymer coatings on metal microneedles for enhanced drug delivery
    Ullah, Asad
    Kim, Chul Min
    Kim, Gyu Man
    ROYAL SOCIETY OPEN SCIENCE, 2018, 5 (04):
  • [38] Polysulfone polymer coating for drug-eluting stents: Advantages of polymer based drug delivery without increased incidence of stent thrombosis
    Mayr, Harold
    Beinhauer, Andreas
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 163L - 163L
  • [39] Mortality and Major Adverse Cardiovascular Events of Polymer Free Drug Coated Stents versus Polymer Based Drug Eluting Stents: A Meta-Analysis of Randomized Controlled Trials
    Panchal, Hemang
    Bhattad, Venugopal
    Murtaza, Ghulam
    Vladimirov, George
    Paul, Timir
    Bhatheja, Samit
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B192 - B192
  • [40] Novel enhanced drug delivery and sensing capabilities of Fe and Au nanoclusters on graphyne: a DFT study with ertapenem drug
    Pishnamazi, Mahboubeh
    Alshehri, Sameer
    Alzhrani, Rami M.
    Al Shmrany, Humood
    SCIENTIFIC REPORTS, 2024, 14 (01):