Modelling of heat transfer in hot strip mill runout table cooling

被引:8
|
作者
Timm, W [1 ]
Weinzierl, K
Leipertz, A
Zieger, H
Zouhar, G
机构
[1] Univ Erlangen Nurnberg, LTT, D-8520 Erlangen, Germany
[2] Siemens ATD, Erlangen, Germany
[3] Dresden Univ Technol, Dresden, Germany
来源
STEEL RESEARCH | 2002年 / 73卷 / 03期
关键词
D O I
10.1002/srin.200200180
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The need for accurate prediction and control of cooling profiles of steel strips on runout tables has led to the development of a mathematical model that is able to predict coiler temperatures under any given condition with an accuracy of +/- 14degreesC as well as calculating the entire temperature profile of a steel strip with sufficient accuracy. Comparisons with online strip temperature data at various locations of the runout table, which were obtained by a new experimental procedure, show that the effect of single cooling headers on the thermal response of a steel strip can be predicted. The model takes into account all relevant thermodynamic effects by means of a statistical approach. Heat transfer to the environment, steel thermophysical properties and phase transformation are modelled using B-splines. Model adaptation is realised by fitting calculated and measured coiler temperatures of approximately 40000 strips with a least square method in order to gain optimal base values for the B-spline functions. During model development special attention was paid to the model's capability of being re-adjustable to a large variety of conditions as well as its local behaviour. Therefore, concepts like temperature-dependent heat transfer coefficients, which are applicable only to one specific plant, have been avoided in favour of a more generalised formulation of the model that helps to gain insight into the physics of the processes involved, i.e. heat transfer of subcooled jet impingement boiling and film boiling. It was found that both cooling water and steel surface temperature have a large influence on heat transfer whereas the influence of strip speed can be neglected.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 50 条
  • [21] Wide Strip Hot Rolling Mill Runout Roll Table Electric Drive Control System
    Lukyanov, S. I.
    Pishnograev, R. S.
    Shvidchenko, N. V.
    2016 IX INTERNATIONAL CONFERENCE ON POWER DRIVES SYSTEMS (ICPDS), 2016,
  • [22] Development and deployment of online multifrequency electromagnetic system to monitor steel hot transformation on runout table of hot strip mill
    Zhu, W.
    Yang, H.
    Luinenburg, A.
    van den Berg, F.
    Dickinson, S.
    Yin, W.
    Peyton, A. J.
    IRONMAKING & STEELMAKING, 2014, 41 (09) : 685 - 693
  • [23] DEVELOPMENT OF A CONTROL SYSTEM FOR RUNOUT TABLE COOLING (DEVELOPMENT OF COOLING CONTROL WITH CURTAIN-WALL-COOLING FOR HOT STRIP - II).
    Takahashi, Ryoichi
    Oshima, Kazuo
    Tachibana, Hidefumi
    Honjyo, Motoi
    Yamamoto, Akio
    Kimura, Toshikazu
    Kuramachi, Toshio
    Transactions of the Iron and Steel Institute of Japan, 1985, 26 (06)
  • [24] Real time simulator for the runout table of hot strip mills
    Kumar, RK
    Sinha, SK
    Lahiri, AK
    IAS '96 - CONFERENCE RECORD OF THE 1996 IEEE INDUSTRY APPLICATIONS CONFERENCE, THIRTY-FIRST IAS ANNUAL MEETING, VOLS 1-4, 1996, : 2547 - 2554
  • [25] Ultra-fast cooling on the run-out table of the hot strip mill
    Simon, P
    Fishbach, JP
    Riche, P
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1996, 93 (03): : 409 - &
  • [26] IMPINGEMENT COOLING OF HOT METAL STRIPS IN RUNOUT TABLE - A REVIEW
    Mishra, Purna Ch.
    Nayak, Santosh K.
    Pradhan, Premananda
    Ghosh, Durga P.
    INTERFACIAL PHENOMENA AND HEAT TRANSFER, 2015, 3 (02) : 117 - 137
  • [27] DEVELOPMENT OF COOLING CONTROL WITH CURTAIN-WALL-COOLING FOR HOT STRIP .2. DEVELOPMENT OF A CONTROL-SYSTEM FOR RUNOUT TABLE COOLING
    TAKAHASHI, R
    OSHIMA, K
    TACHIBANA, H
    HONJYO, M
    YAMAMOTO, A
    KIMURA, T
    KURAMACHI, T
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 26 (06) : B204 - B204
  • [28] An on-line parallel controller for the runout table of hot strip mills
    Kumar, RK
    Sinha, SK
    Lahiri, AK
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2001, 9 (06) : 821 - 830
  • [29] REDUCTION OF STRIP EDGE COOLING IN A HOT WIDE STRIP MILL
    FABIAN, W
    KOPINECK, HJ
    TAPPE, W
    WLADIKA, H
    STAHL UND EISEN, 1987, 107 (07): : 319 - 323
  • [30] DEVELOPMENT AND IMPROVEMENT OF STRIP COOLING EQUIPMENT ON HOT STRIP MILL
    TOKUSHIGE, K